Cited by 30Analog and Mixed-Signal Circuit DesignNeuroscience and Neural EngineeringRadio Frequency Integrated Circuit Design

Neural Recording Front-End Designs for Fully Implantable Neuroscience Applications and Neural Prosthetic Microsystems

Perlin, G. E., Sodagar, A. M., Wise, K. D.·2006·2006 International Conference of the IEEE Engineering in Medicine and Biology Society

Abstract

An implantable neural recording front-end has been designed in two versions. The first is a multi-channel signal-conditioning ASIC for use with any neural recording probe technology. This ASIC was implemented in a commercial 0.5 mum CMOS process, includes 16 parallel amplifier channels, and measures 2.3 mm2 The amplifiers have a gain of 59.5 dB, a high cutoff frequency at 9.1 kHz and consume 75 microW per channel. The low cutoff frequency is independently tunable on each channel to accept or reject field potentials. This chip is small enough to be chronically packaged for experiments in awake behaving animals or it can be integrated into a fully implantable neural recording microsystem. The second version of the front-end is a neural recording probe with integrated signal conditioning circuitry on the back-end implemented in a 3 microm CMOS process. This version dissipates 142 microW and includes 64 to 8 site selection, 8 per-channel amplifiers each having a gain of 50.2 dB, a tunable low cutoff frequency, and a 7 kHz upper cutoff frequency. Real-time site impedance and circuit testing has been integrated in this design.

Integrity signals

Registry

Crossref · 10.1109/iembs.2006.260193

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Multiplexing a high-density electrode array to a smaller amplifier array is a widely used resource-sharing technique that relies on not all electrode sites providing useful information after implantation or on necessary information being obtainable from a small subset, although the useful subset is not known in advance.

    “The first widely used technique consists of multiplexing a high-density electrode array to a much smaller amplifier array. This strategy leverages the fact that not all electrode sites may provide useful information after implantation [97, 101, 145] or that the necessary information can be obtained from a small subset of electrodes, although the useful electrode subset is not known a priori [118].”

The citation lists haven’t been fetched yet

References 12 · Cited by 30

Authors
Perlin, G. E., Sodagar, A. M., & Wise, K. D.
Affiliations
University of Michigan (US)
Venue
2006 International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2006-08
Volume
2006
Pages
2982-2985
ISSN
2375-7477 (ISSN-L)
OpenAlex
W1573495382
Cited by
30
References
12
Citations by year
2022: 1 · 2017: 1 · 2016: 2 · 2015: 4 · 2014: 2 · 2013: 1 · 2012: 2
FWCI
9.42
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (n01ns002329-001)
  • National Institute of Neurological Disorders and Stroke (N01-NS02329)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
implantable neural recording, neuroprosthetics, CMOS integrated circuit, low-power amplifier, field potentials
MeSH terms
Amplifiers, Electronic, Animals, Biomedical Engineering, Electrodes, Implanted, Electronics, Medical, Humans, Man-Machine Systems, Neurosciences, Prosthesis Design

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review