Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Open accessAbstract
Neural signal recording is critical in modern day neuroscience research and emerging neural prosthesis programs. Neural recording requires the use of precise, low-noise amplifier systems to acquire and condition the weak neural signals that are transduced through electrode interfaces. Neural amplifiers and amplifier-based systems are available commercially or can be designed in-house and fabricated using integrated circuit (IC) technologies, resulting in very large-scale integration or application-specific integrated circuit solutions. IC-based neural amplifiers are now used to acquire untethered/portable neural recordings, as they meet the requirements of a miniaturized form factor, light weight and low power consumption. Furthermore, such miniaturized and low-power IC neural amplifiers are now being used in emerging implantable neural prosthesis technologies. This review focuses on neural amplifier-based devices and is presented in two interrelated parts. First, neural signal recording is reviewed, and practical challenges are highlighted. Current amplifier designs with increased functionality and performance and without penalties in chip size and power are featured. Second, applications of IC-based neural amplifiers in basic science experiments (e.g., cortical studies using animal models), neural prostheses (e.g., brain/nerve machine interfaces) and treatment of neuronal diseases (e.g., DBS for treatment of epilepsy) are highlighted. The review concludes with future outlooks of this technology and important challenges with regard to neural signal amplification.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 136 cited sources checked · 0 supported · 0 flagged
- Findingown data
Several designs in Table 1 reach hundreds of channels while still meeting small die size, low power and low noise criteria.
“Various solutions in Table 1 achieve hundreds of channels while meeting the criteria of a small die size, low power consumption and low noise.”
Quote in the paperNot a substantial claim - Findingown data
The smallest process features used in the reviewed CNS neural amplifier ICs have shrunk to 180 nm.
“Of note is the reduction in the process dimensions (smallest features), which has been reduced to 180 nm.”
Quote in the paperNot a substantial claim - Premisecitation
Modern circuit designs and IC fabrication technologies have produced innovative designs that allow designers to relax the size-functionality compromises.
“However, modern circuit designs [77, 92] and IC fabrication technologies [18, 86] have resulted in innovative designs, enabling designers to relax such compromises.”
Quote in the paperNot a substantial claim0 of 4 sources checked- cites [77] Lopez CM, Andrei A, Mitra S, Welkenhuysen M, Eberle W, Bartic C, Puers R, Yazicioglu RF, Gielen GGE (2014) An implantable 455-active-electrode 52-channel CMOS neural probe. IEEE J Solid State Circuits 49(1):248–261 source
Not checked in the free run.
- cites [92] Ng KA, Xu YP (2013) A compact, low input capacitance neural recording amplifier. IEEE Trans Biomed Circuits Syst 7(5):610–620 source
Not checked in the free run.
- cites [18] Chen Y, Basu A, Liu L, Zou X, Rajkumar R, Dawe GS, Je M (2014) A digitally assisted, signal folding neural recording amplifier. IEEE Trans Biomed Circuits Syst 8(4):528–542 source
Not checked in the free run.
- cites [86] Muller R, Gambini S, Rabaey JM (2013) A 0.013 mm 2, 5 µW, DC-Coupled neural signal acquisition IC With 0.5 V supply. IEEE J Solid State Circuits 47(1):232–243 source
Not checked in the free run.
- Premisenone given
Repeated ESD exposure to the pins of neural ICs causes latent and cumulative soft damage.
“Furthermore, latent and cumulative soft damage occurs when the pins of neural ICs are repeatedly subjected to ESD, as would occur when an unknowingly charged human operator repeatedly handles the IC amplifier terminals.”
Quote in the paperNot a substantial claim - Premisecitation
Vulnerability to electrostatic discharge from a charged human operator or during machine-based assembly is a critical consideration for neural amplifier ICs, especially in dry environments.
“Vulnerability to an electrostatic discharge (ESD) from a charged human operator or during machine-based assembly processes is another critical consideration [33, 115]. This is a particularly serious problem when the amplifier IC is used in dry environments, such as in the operating theater or in dry climates.”
Quote in the paperNot a substantial claim0 of 2 sources checked
- Premisereasoning
IC-based neural amplifiers are used for untethered or portable neural recordings because they satisfy miniaturized form factor, light weight, and low power consumption requirements.
“IC-based neural amplifiers are now used to acquire untethered/portable neural recordings, as they meet the requirements of a miniaturized form factor, light weight and low power consumption.”
Quote in the paperSubstantial claim - Premisecitation
An implanted chronic recording device with a neural amplifier IC should produce less than 40 mW/cm2 of heat flux to avoid heating surrounding nerve tissue by more than 2 °C, above which tissue or nerve necrosis occurs.
“When a recording device containing a neural amplifier IC is implanted for chronic recording, the device should generate less than 40 mW/cm2 of heat flux to prevent heating the surrounding nerve tissues by more than 2 °C, beyond which tissue/nerve necrosis occurs [146].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [146] Wolf PD (2008) Thermal considerations for the design of an implanted cortical brain—machine interface (BMI). In: Indwelling neural implants, 1st ed. CRC Press, Boca Raton, 63–86
Not checked in the free run.
- Interpretationcitation
Sharing the reference branch of one front-end amplifier among multiple channels cannot be scaled beyond four channels because of inter-channel crosstalk.
“However, this technique cannot be scaled beyond 4 channels due to inter-channel crosstalk.”
Quote in the paperNot a substantial claim - Premisecitation
Electrode background noise power can vary from site to site because of the electrode's material properties and the activity of non-isolated neurons.
“Further, the electrode’s background noise power can vary from site to site due to both the material properties of the electrode and the activities of non-isolated neurons [25].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [25] Cogan SF (2008) Neural stimulation and recording electrodes. Annu Rev Biomed Eng 10:275–309 source
Not checked in the free run.
- Premisenone given
A typical ESD event disconnects the input terminals of an IC neural amplifier from the electrodes, disabling the still-functional amplifier's ability to acquire neural signals.
“A typical ESD event would disconnect the input terminals of an IC neural amplifier from the electrodes, disabling the still functional amplifiers’ ability to acquire the neural signals.”
Quote in the paperNot a substantial claim - Interpretationreasoning
Low-power neural amplifier designs are essential to mitigate the challenge of electromagnetic power transfer for implantable systems.
“Therefore, low-power neural amplifier designs are essential to mitigating this challenge.”
Quote in the paperSubstantial claim - Premisereasoning
Another power-scheduling method is to adapt each amplifier channel's current consumption according to the background noise at its respective electrode.
“Therefore, another power-scheduling method is to adapt the current consumption of each amplifier channel according to the background noise present at the respective electrode [17, 122, 141].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [17] Chaturvedi V, Amrutur B (2011) An area-efficient noise-adaptive neural amplifier in 130 cmos technology. IEEE J Emerg Sel Top Circuits Syst 1(4):536–545 source
Not checked in the free run.
- cites [122] Sarpeshkar R, Wattanapanitch W, Arfin SK, Rapoport BI, Mandal S, Baker MW, Fee MS, Musallam S, Andersen RA (2008) Low-power circuits for brain-machine interfaces. IEEE Trans Biomed Circuits Syst 2(3):173–183 source
Not checked in the free run.
- cites [141] Wattanapanitch W, Sarpeshkar R (2011) A low-power 32-channel digitally programmable neural recording integrated circuit. IEEE Trans Biomed Circuits Syst 5(6):592–602 source
Not checked in the free run.
- Premisecitation
Neural recording is universally performed using a differential recording setup to suppress interference as much as possible.
“To suppress such interference as much as possible, neural recording is universally performed using the differential recording setup illustrated in Fig. 2 [143].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [143] Webster JG (ed) (1998) Medical instrumentation: application and design. Wiley, New york
Not checked in the free run.
- Rests on an assumption: Interfering noise sources are at least ten times larger than the neural signals of interest and can mask or corrupt the acquired neural signal.
- Premisecitation
It is common for multiple amplifier channels to share a single ADC or output driver in a time-multiplexed sequence.
“For example, it is common for multiple amplifier channels to share a single ADC or output driver in a time-multiplexed sequence [1, 51, 73, 94].”
Quote in the paperNot a substantial claim0 of 4 sources checked- cites [1] Abdelhalim K, Jafari HM, Kokarovtseva L, Velazquez JLP, Genov R, Luis J, Velazquez P, Genov R (2013) 64-Channel UWB wireless neural vector analyzer soc with a closed-loop phase synchrony-triggered neurostimulator. IEEE J Solid-State Circuits 48(10):2494–2510 source
Not checked in the free run.
- cites [51] Harrison RR (2007) A versatile integrated circuit for the acquisition of biopotentials. In: Proceedings of IEEE conference on custom integrated circuits, 115–122 source
Not checked in the free run.
- cites [73] Liew W-S, Zou X, Yao L, Lian Y (2009) A 1-V 60-µW 16-channel interface chip for implantable neural recording. In: IEEE custom integrated circuits conference, no. CICC, 507–510
Not checked in the free run.
- cites [94] Ng KA, Xu L, Li X, Yen S, Je M, Xu YP, Tan TC (2012) An inductively powered CMOS multichannel bionic neural link for peripheral nerve function restoration. In: IEEE asian solid state circuits conference, 181–184 source
Not checked in the free run.
- Premisenone given
Three system-level techniques commonly used to minimize power in neural recording systems are resource sharing, power scheduling, and power supply voltage reduction.
“Here, we describe three system-level techniques commonly used to minimize the power consumed by a neural recording system. The first strategy is resource sharing. The second strategy is power scheduling. The final strategy is power supply voltage reduction.”
Quote in the paperNot a substantial claim - Premisecitation
In some designs, when channels were not sampled by the ADC, they were put into a sleep mode in which power consumption was maintained at a level that minimized wake-up time.
“For example, in [67, 156], when channels were not sampled by the ADC, they were put into a sleep mode where the channel’s power consumption was maintained at a level to minimize the wake-up time.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [67] Lee SB, Lee H-M, Kiani M, Jow U-M, Ghovanloo M (2010) An inductively powered scalable 32-channel wireless neural recording system-on-a-chip for neuroscience applications. IEEE Trans Biomed Circuits Syst 4(6):360–371 source
Not checked in the free run.
- cites [156] Zou X, Liu L, Cheong JH, Yao L, Li P, Cheng MY, Goh WL, Rajkumar R, Dawe GS, Cheng KW, Je M (2013) A 100-channel 1-mW implantable neural recording IC. IEEE Trans Circuits Syst I 60(10):2584–2596 source
Not checked in the free run.
- Premisereasoning
Minimizing total power consumption is important for neural recording systems, especially those intended for portable use or implantation.
“Minimizing the total power consumption for such neural recording systems is an important task, especially for such systems that are designed for portable applications or implantation.”
Quote in the paperSubstantial claim - Premisecitation
Majidzadeh et al. demonstrated sharing the reference branch of one front-end amplifier among multiple channels.
“A recent work by Majidzadeh et al. [78] demonstrated how to share the reference branch of one front-end amplifier among multiple channels.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [78] Majidzadeh V, Schmid A, Leblebici Y (2011) Energy efficient low-noise neural recording amplifier with enhanced noise efficiency factor. IEEE Trans Biomed Circuits Syst 5(3):262–271 source
Not checked in the free run.
- Premisecitation
Sansen's comprehensive noise-versus-power analysis concluded that the 2-stage Miller OTA and the symmetrical cascode OTA have higher, worse obtainable NEFs than the alternative topologies.
“A comprehensive noise-versus-power consumption analysis of the OTAs, as shown in Fig. 5, was performed by Sansen [119], which led to the conclusion that the 2-stage Miller OTA (Fig. 5a) and the symmetrical cascode OTA (Fig. 5b) have higher (worse) obtainable NEFs compared to the alternative topologies.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [119] Sansen WMC (2006) Analog design essentials. Springer, Netherlands
Not checked in the free run.
- Premisenone given
For recording systems that must operate below 2.5 V and use CMOS processes without low-threshold transistors, the telescopic cascode OTA cannot be used because it requires at least 2.5 V.
“For recording systems that must operate at supply voltages below 2.5 V and that must be implemented with CMOS processes lacking transistors with low threshold voltages, the telescopic cascode OTA cannot be used, as it requires at least 2.5 V to operate.”
Quote in the paperNot a substantial claim - Premisecitation
The inadequacy of NEF alone becomes more pronounced because recent works have reported operating supply voltages below 1 V.
“This inadequacy becomes more pronounced, as recent works have reported operating supply voltages below 1 V [49, 129, 156].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [49] Han D, Zheng Y, Rajkumar R, Dawe G, Je M (2014) A 0.45 V 100-channel neural-recording IC with sub-µW/channel consumption in 0.18 µm CMOS. IEEE Trans Biomed Circuits Syst 7(6):735–746 source
Not checked in the free run.
- cites [129] Song S, Rooijakkers MJ, Harpe P, Rabotti C, Mischi M, Van Roermund AHM, Cantatore E (2013) A 430nW 64nV/√ Hz current-reuse telescopic amplifier for neural recording applications. In: Biomedical circuits and systems conference (BioCAS), 2013 IEEE, vol. 1, 322–325 source
Not checked in the free run.
- cites [156] Zou X, Liu L, Cheong JH, Yao L, Li P, Cheng MY, Goh WL, Rajkumar R, Dawe GS, Cheng KW, Je M (2013) A 100-channel 1-mW implantable neural recording IC. IEEE Trans Circuits Syst I 60(10):2584–2596 source
Not checked in the free run.
- Premisecitation
Wattanapanitch and Sarpeshkar partitioned an IC neural amplifier into two voltage domains, with front-end amplifiers at 1.8 V and the ADC and backend digital blocks at 1 V to reduce dynamic switching power.
“For example, the IC neural amplifier reported by Wattanapanitch and Sarpeshkar [141] was partitioned into two separate voltage domains. The front-end amplifiers operated at 1.8 V, while the supply voltage of the ADC and the backend digital blocks were reduced to 1 V to decrease the dynamic switching power.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [141] Wattanapanitch W, Sarpeshkar R (2011) A low-power 32-channel digitally programmable neural recording integrated circuit. IEEE Trans Biomed Circuits Syst 5(6):592–602 source
Not checked in the free run.
- Premisecitation
The input-referred noise of the OTA arises from thermal noise and flicker noise in the transistors' conduction channels.
“In all cases, the input-referred noise of the OTA arises from the thermal noise and flicker noise of the transistors’ conduction channels [43].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [43] Gray PR, Hurst PJ, Meyer RG, Lewis SH (2009) Analysis and design of analog integrated circuits. 5th edn. Wiley, US
Not checked in the free run.
- Interpretationreasoning
To reduce input-referred noise, NEF, and PEF, input transistors are usually operated in weak inversion and supplied with a large bias current.
“Therefore, to reduce the input-referred noise, the NEF and the PEF, the input transistors are usually operated in the weak inversion region and supplied with a large biasing current.”
Quote in the paperNot a substantial claim - Premisenone given
The front-end amplifier circuit design deserves special attention because its electrical performance directly determines the overall recording system's performance.
“The circuit design of the front-end amplifier in Fig. 3 deserves special attention, as the electrical performance of this amplifier directly determines the performance of the overall recording system.”
Quote in the paperNot a substantial claim - Interpretationreasoning
The current-reuse arrangement reduces the thermal noise component of input-referred noise, and hence the NEF, by a factor of √2.
“This leads to a reduction in the thermal noise component of the input-referred noise (and hence the NEF) by a factor of √2.”
Quote in the paperNot a substantial claim- The authors state this as an assumption: The transconductance of the NMOS and PMOS input devices is assumed to be equal.
- Premisereasoning
On-chip signal processing, including spike detection and other data compression, is an emerging trend aimed at reducing transmitted data.
“Another emerging trend includes on-chip signal processing, such as spike detection [16, 54] or other forms of data compression [108, 132, 155] to reduce the amount of transmitted data.”
Quote in the paperNot a substantial claim0 of 5 sources checked- cites [16] Chae M, Yang Z, Yuce M, Hoang L, Liu W (2009) A 128-channel 6 mW wireless neural recording IC with spike feature extraction and UWB transmitter. IEEE Trans Neural Syst Rehabil Eng 17(4):312–321 source
Not checked in the free run.
- cites [54] Harrison R, Watkins P (2007) A low-power integrated circuit for a wireless 100-electrode neural recording system. IEEE J Solid State Circuits 42(1):123–133 source
Not checked in the free run.
- cites [108] Rodriguez-Perez A, Ruiz-Amaya J, Delgado-Restituto M, Rodriguez-Vazquez A (2012) A low-power programmable neural spike detection channel with embedded calibration and data compression. IEEE Trans Biomed Circuits Syst 6(2):87–100 source
Not checked in the free run.
- cites [132] Suo Y, Zhang J, Xiong T, Chin PS, Etienne-Cummings R, Tran TD (2014) Energy-efficient multi-mode compressed sensing system for implantable neural recordings. IEEE Trans Biomed Circuits Syst 8(5):648–659 source
Not checked in the free run.
- cites [155] Zhang J, Mitra S, Suo Y, Cheng A, Xiong T, Michon F, Welkenhuysen M, Kloosterman F, Chin PS, Hsiao S (2015) A closed-loop compressive-sensing-based neural recording system. J Neural Eng 12(3):36005 source
Not checked in the free run.
- Premisereasoning
Resource sharing, generally employed at the system level, can increase the power efficiency of the front-end amplifier.
“Resource sharing, which is generally employed at the system level, can be used to increase the power efficiency of the front-end amplifier.”
Quote in the paperNot a substantial claim - Premisecitation
Neural amplifier ICs have been created that capture both action potentials and local field potentials, with separate filtering, amplification and output for each signal type.
“CNS amplifiers have also been developed that can acquire both types of signals, separately filtering, amplifying and outputting each signal type [46, 86, 100].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [46] Guo J, Yuan J, Huang J, Law JKY, Yeung CK, Chan M (2012) 32.9 nV/rt Hz—60.6 dB THD dual-band micro-electrode array signal acquisition IC. IEEE J Solid State Circuits 47(5):1209–1220 source
Not checked in the free run.
- cites [86] Muller R, Gambini S, Rabaey JM (2013) A 0.013 mm 2, 5 µW, DC-Coupled neural signal acquisition IC With 0.5 V supply. IEEE J Solid State Circuits 47(1):232–243 source
Not checked in the free run.
- cites [100] Perelman Y, Ginosar R (2007) An integrated system for multichannel neuronal recording with spike/LFP separation, integrated A/D conversion and threshold detection. IEEE Trans Biomed Eng 54(1):130–137 source
Not checked in the free run.
- Premisereasoning
The closed-loop gain of the common front-end amplifier is accurately defined by the ratio Cin/Cfb.
“The closed-loop gain is therefore accurately defined by the ratio Cin/Cfb.”
Quote in the paperNot a substantial claim - Interpretationreasoning
The NEF alone is not sufficient to compare neural amplifiers operated at different supply voltages.
“However, the NEF alone is not a sufficient metric to compare neural amplifiers that are operated at different supply voltages.”
Quote in the paperNot a substantial claim - Premisecitation
Recent works using the telescopic cascode OTA achieved consistently low NEF values below 2.6.
“Recent works [94, 149], which used the telescopic cascode OTA, achieved consistently low NEF values below 2.6.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [94] Ng KA, Xu L, Li X, Yen S, Je M, Xu YP, Tan TC (2012) An inductively powered CMOS multichannel bionic neural link for peripheral nerve function restoration. In: IEEE asian solid state circuits conference, 181–184 source
Not checked in the free run.
- cites [149] Xu YP, Yen SC, Ng KA, Liu X, Tan TC (2012) A bionic neural link for peripheral nerve repair. In: Proceedings of international conference IEEE engineering in medicine and biology society, 1335–1338
Not checked in the free run.
- Interpretationreasoning
The folded cascode OTA is the natural choice for front-end amplifiers operating below 3 V and requiring low NEF and PEF values.
“Instead, the folded cascode OTA (Fig. 5d) is the natural choice for front-end amplifiers operating at supply voltages below 3 V and requiring low NEF and PEF values [103, 141, 142].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [103] Qian C, Parramon J, Sanchez-Sinencio E (2011) A micropower low-noise neural recording front-end circuit for epileptic seizure detection. IEEE J Solid State Circuits 46(6):1392–1405 source
Not checked in the free run.
- cites [141] Wattanapanitch W, Sarpeshkar R (2011) A low-power 32-channel digitally programmable neural recording integrated circuit. IEEE Trans Biomed Circuits Syst 5(6):592–602 source
Not checked in the free run.
- cites [142] Wattanapanitch W, Fee M, Sarpeshkar R (2007) An energy-efficient micropower neural recording amplifier. IEEE Trans Biomed Circuits Syst 1(2):136–147 source
Not checked in the free run.
- Premisereasoning
In a current-reuse amplifier topology, two complementary input pairs are used within the same amplifier, allowing the NEF to be reduced by a factor of √2.
“Here, two complementary input pairs (P1, N1) and (P2, N2) are used within the same amplifier, which allows the NEF to be reduced by a factor of √2.”
Quote in the paperNot a substantial claim - Premisecitation
Previous studies using either a symmetrical cascode OTA or a 2-stage Miller OTA reported NEFs ranging from 4 to 17.
“Indeed, previous studies [53, 98, 128], which used either a symmetrical cascode OTA or a 2-stage Miller OTA, reported NEFs ranging from 4 to 17.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [53] Harrison RR, Charles C (2003) A low-power low-noise CMOS amplifier for neural recording applications. IEEE J Solid State Circuits 38(6):958–965 source
Not checked in the free run.
- cites [98] Olsson R, Buhl D, Sirota AM, Buzsáki G, Wise KD (2005) Band-tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays. IEEE Trans Bio-Med Eng 52(7):1303–1311 source
Not checked in the free run.
- cites [128] Sodagar AM, Perlin GE, Yao Y, Najafi K, Wise KD (2009) An implantable 64-channel wireless microsystem for single-unit neural recording. IEEE J Solid State Circuits 44(9):2591–2604 source
Not checked in the free run.
- Premisecitation
Amplifiers using the current-reuse topology achieve state-of-the-art noise performance.
“Amplifiers using this topology achieve state-of-the-art noise performance [49, 129, 156].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [49] Han D, Zheng Y, Rajkumar R, Dawe G, Je M (2014) A 0.45 V 100-channel neural-recording IC with sub-µW/channel consumption in 0.18 µm CMOS. IEEE Trans Biomed Circuits Syst 7(6):735–746 source
Not checked in the free run.
- cites [129] Song S, Rooijakkers MJ, Harpe P, Rabotti C, Mischi M, Van Roermund AHM, Cantatore E (2013) A 430nW 64nV/√ Hz current-reuse telescopic amplifier for neural recording applications. In: Biomedical circuits and systems conference (BioCAS), 2013 IEEE, vol. 1, 322–325 source
Not checked in the free run.
- cites [156] Zou X, Liu L, Cheong JH, Yao L, Li P, Cheng MY, Goh WL, Rajkumar R, Dawe GS, Cheng KW, Je M (2013) A 100-channel 1-mW implantable neural recording IC. IEEE Trans Circuits Syst I 60(10):2584–2596 source
Not checked in the free run.
- Premisenone given
Among weak, mid, and strong inversion operation, weak inversion achieves the highest transconductance per unit ampere of bias current.
“The transistors can be operated in either weak, midor strong inversion, of which the former achieves the highest transconductance (gm) per unit ampere of bias current.”
Quote in the paperNot a substantial claim - Premisecitation
Reducing the supply voltage of the entire chip or of individual subsystems can be a very effective way to reduce power.
“Finally, reducing the supply voltage of the entire chip or individual subsystems can be a very effective method to reduce power.”
Quote in the paperNot a substantial claim - Interpretationreasoning
Because non-human primates need large roaming areas, the short-range wireless power methods used for rodents are inadequate for powering their neural recording systems.
“Due to the large roaming space required by NHPs, the short-range wireless power harvesting methods described for rodents, such as in [67] and [64], are not sufficient to wirelessly power neural recording systems for NHP studies.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [67] Lee SB, Lee H-M, Kiani M, Jow U-M, Ghovanloo M (2010) An inductively powered scalable 32-channel wireless neural recording system-on-a-chip for neuroscience applications. IEEE Trans Biomed Circuits Syst 4(6):360–371 source
Not checked in the free run.
- cites [64] Jow U-M, McMenamin P, Kiani M, Manns JR, Ghovanloo M (2014) EnerCage: a smart experimental arena with scalable architecture for behavioral experiments. IEEE Trans Biomed Eng 61(1):139–148 source
Not checked in the free run.
- Premisecitation
Intrafascicular electrodes such as TIME and LIFE transduce signals with amplitudes below 100 μVpp.
“For example, intrafascicular electrodes, such as the transverse intrafascicular multichannel electrode (TIME) and the longitudinal intrafascicular electrode (LIFE), transduce signals that have amplitudes less than 100 µVpp [62, 66, 71, 79, 82, 109].”
Quote in the paperSubstantial claim0 of 6 sources checked- cites [62] Jia X, Koenig MA, Zhang X, Zhang J, Chen T, Chen Z (2007) Residual motor signal in long-term human severed peripheral nerves and feasibility of neural signal-controlled artificial limb. J Hand Surg Am 32(5):657–666 source
Not checked in the free run.
- cites [66] Lawrence SM, Dhillon GS, Jensen W, Yoshida K, Horch KW (2004) Acute peripheral nerve recording characteristics of polymer-based longitudinal intrafascicular electrodes. IEEE Trans Neural Syst Rehabil Eng 12(3):345–348 source
Not checked in the free run.
- cites [71] Li L-J, Zhang J, Zhang F, Lineaweaver WC, Chen T-Y, Chen Z-W (2005) Longitudinal intrafascicular electrodes in collection and analysis of sensory signals of the peripheral nerve in a feline model. Microsurgery 25(7):561–565 source
Not checked in the free run.
- cites [79] Malagodi MS, Horch KW, Schoenberg AA (1989) An intrafascicular electrode for recording of action potentials in peripheral nerves. Ann Biomed Eng 17(4):397–410 source
Not checked in the free run.
- cites [82] Micera S, Rossini PM, Rigosa J, Citi L, Carpaneto J, Raspopovic S, Tombini M, Cipriani C, Assenza G, Carrozza MC, Hoffmann K-P, Yoshida K, Navarro X, Dario P (2011) Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces. J Neuroeng Rehabil 8:53 source
Not checked in the free run.
- cites [109] Rossini PM, Micera S, Benvenuto A, Carpaneto J, Cavallo G, Citi L, Cipriani C, Denaro L, Denaro V, Di Pino G, Ferreri F, Guglielmelli E, Hoffmann KP, Raspopovic S, Rigosa J, Rossini L, Tombini M, Dario P (2010) Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiol 121(5):777–783 source
Not checked in the free run.
- Interpretationnone given
Reported PNS neural amplifiers generally use more power per channel to achieve the much lower noise needed for at least an SNR of 2.
“In general, the reported PNS neural amplifiers consume higher power per channel to achieve a much lower noise level for maintaining at least a signal-to noise ratio (SNR) of 2.”
Quote in the paperNot a substantial claim - Interpretationreasoning
Consequently, every current wireless recording system for primate studies relies on a lightweight battery pack, usually mounted on the head.
“All current wireless recording systems for primate studies therefore require a light-weight battery pack, which is often head mounted.”
Quote in the paperNot a substantial claim - Interpretationnone given
Recording instrumentation for very small subjects such as insects must achieve extreme reductions in size, weight and power use.
“Wireless recording instrumentation designed for small subjects, such as insects, requires very aggressive reductions in size, weight and power consumption.”
Quote in the paperNot a substantial claim - Interpretationnone given
The reported system-on-chip solutions need a battery for power.
“The reported system-on-chip solutions require a battery as a power supply.”
Quote in the paperSubstantial claim - Premisecitation
The ability of velocity selection recording to discriminate recorded activity by fiber type has been validated in several acute in vivo studies.
“The ability of VSR to discriminate recorded activity based on fiber type has been validated in several acute in vivo studies [123, 124, 153]; demonstrating this technique in a chronically implanted model would represent a major advancement.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [123] Schuettler M, Seetohul V, Rijkhoff NJM, Moeller FV, Donaldson N, Taylor J (2011) Fibre-selective recording from peripheral nerves using a multiple-contact cuff: report on pilot pig experiments. In: IEEE engineering in medicine and biology conference, 3103–3106 source
Not checked in the free run.
- cites [124] Schuettler M, Donaldson N, Seetohul V, Taylor J (2013) Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff. J Neural Eng 10(3):036016 source
Not checked in the free run.
- cites [153] Yoshida K, Kurstjens GAM, Hennings K (2009) Experimental validation of the nerve conduction velocity selective recording technique using a multi-contact cuff electrode. Med Eng Phys 31(10):1261–1270 source
Not checked in the free run.
- Interpretationreasoning
To keep a signal-to-noise ratio above 1.5, peripheral neural amplifiers coupled to extracellular electrodes are typically designed with input-referred noise below 12 μVpp, much lower than normal CNS amplifiers.
“Hence, to maintain a signal-to-noise ratio of more than 1.5, the peripheral neural amplifiers that are coupled with extracellular electrodes are typically designed with a much lower input-referred noise (<12 µVpp) than normal CNS-based neural amplifiers.”
Quote in the paperNot a substantial claim - Premisecitation
Extrafascicular electrodes such as nerve cuff electrodes transduce signals with amplitudes below 20 μVpp.
“In addition, the signals transduced by extrafascicular electrodes, such as nerve cuff electrodes, have amplitudes less than 20 µVpp [41, 75, 127, 138].”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [41] Gordon T, Hoffer JA, Jhamandas J, Stein RB (1980) Long-term effects of axotomy on neural activity during cat locomotion. J Physiol 303:243–263 source
Not checked in the free run.
- cites [75] Loeb GE, Peck RA (1996) Cuff electrodes for chronic stimulation and recording of peripheral nerve activity. J Neurosci Methods 64:95–103 source
Not checked in the free run.
- cites [127] Sinjar T, Hinge B, Jorgensen A, Jensen ML, Haugland M (1992) Whole sensory nerve recordings with spiral nerve cuff electrode. In: IEEE engineering in medicine and biology conference, vol. 4, 1330–1331 source
Not checked in the free run.
- cites [138] Upshaw B, Sinkjaer T (1998) Digital signal processing algorithms for the detection of afferent nerve activity recorded from cuff electrodes. IEEE Trans Rehabil Eng 6(2):172–181 source
Not checked in the free run.
- Interpretationreasoning
This integration has made possible many neuroscience studies using freely moving animal models.
“This has enabled many neuroscientific studies that incorporate freely roaming animal models.”
Quote in the paperNot a substantial claim - Premisecitation
Because of noise constraints, PNS electrophysiological recordings are mostly done with commercial bench-top low-noise amplifier setups that require tethering the subject.
“Due to the noise constraints placed on recording instrumentation, electrophysiological recordings from the PNS are largely performed using commercial bench-top low-noise amplifier setups [75, 82, 109] that require subjects to be tethered to the equipment.”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [75] Loeb GE, Peck RA (1996) Cuff electrodes for chronic stimulation and recording of peripheral nerve activity. J Neurosci Methods 64:95–103 source
Not checked in the free run.
- cites [82] Micera S, Rossini PM, Rigosa J, Citi L, Carpaneto J, Raspopovic S, Tombini M, Cipriani C, Assenza G, Carrozza MC, Hoffmann K-P, Yoshida K, Navarro X, Dario P (2011) Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces. J Neuroeng Rehabil 8:53 source
Not checked in the free run.
- cites [109] Rossini PM, Micera S, Benvenuto A, Carpaneto J, Cavallo G, Citi L, Cipriani C, Denaro L, Denaro V, Di Pino G, Ferreri F, Guglielmelli E, Hoffmann KP, Raspopovic S, Rigosa J, Rossini L, Tombini M, Dario P (2010) Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiol 121(5):777–783 source
Not checked in the free run.
- Interpretationreasoning
Because rodents are small and can carry only limited weight, portable recording systems for rodent studies must be small and light.
“Due to their small size, rodents can bear limited weight and, hence, portable neural recording systems for rodent studies must have a small form factor and low weight.”
Quote in the paperSubstantial claim- Rests on an assumption: Rodents can bear only limited weight, so portable neural recording systems for rodent studies must be small and low weight.
- Premisecitation
All reported BMI experiments with human patients require the subject to be tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
Quote in the paperSubstantial claim0 of 5 sources checked- cites [26] Collinger JL, Wodlinger B, Downey JE, Wang W, Tyler-Kabara EC, Weber DJ, McMorland AJC, Velliste M, Boninger ML, Schwartz AB (2013) High-performance neuroprosthetic control by an individual with tetraplegia. Lancet 381:557–564 source
Not checked in the free run.
- cites [35] Ethier C, Oby ER, Bauman MJ, Miller LE (2012) Restoration of grasp following paralysis through brain-controlled stimulation of muscles. Nature 485(7398):368–371 source
Not checked in the free run.
- cites [57] Hochberg LR, Serruya MD, Friehs GM, Mukand JA, Saleh M, Caplan AH, Branner A, Chen D, Penn RD, Donoghue JP (2006) Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature 442(7099):164–171 source
Not checked in the free run.
- cites [58] Hochberg LR, Bacher D, Jarosiewicz B, Masse NY, Simeral JD, Vogel J, Haddadin S, Liu J, Cash SS, van der Smagt P, Donoghue JP (2012) Reach and grasp by people with tetraplegia using a neurally controlled robotic arm. Nature 485(7398):372–375 source
Not checked in the free run.
- cites [150] Yanagisawa T, Hirata M, Saitoh Y, Goto T, Kishima H, Fukuma R, Yokoi H, Kamitani Y, Yoshimine T (2011) Real-time control of a prosthetic hand using human electrocorticography signals. J Neurosurg 114(6):1715–1722 source
Not checked in the free run.
- Premisecitation
A peripheral nerve-based neuromodulation system for bladder control has been demonstrated in rats.
“Recently, a peripheral nerve-based neuromodulation system for bladder control was demonstrated in rats [22, 28, 80].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [22] Chew DJ, Zhu L, Delivopoulos E, Minev IR, Musick KM, Mosse CA, Craggs M, Donaldson N, Lacour SP, McMahon SB, Fawcett JW (2013) A microchannel neuroprosthesis for bladder control after spinal cord Injury in rat. Sci Transl Med 5(210):210ra155
Not checked in the free run.
- cites [28] Delivopoulos E, Chew DJ, Minev IR, Fawcett JW, Lacour SP (2012) Concurrent recordings of bladder afferents from multiple nerves using a microfabricated PDMS microchannel electrode array. Lab Chip 12(14):2540 source
Not checked in the free run.
- cites [80] Mendez A, Sawan M, Minagawa T, Wyndaele JJ (2013) Estimation of bladder volume from afferent neural activity. IEEE Trans Neural Syst Rehabil Eng 21(5):704–715 source
Not checked in the free run.
- Premisecitation
Sahin et al. demonstrated a closed-loop PNS neuromodulation device for treating obstructive sleep apnea.
“Similarly, Sahin et al. [116] demonstrated a closed-loop PNS neuromodulation device to treat obstructive sleep apnea.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [116] Sahin M, Durand DM, Haxhiu MA (2000) Closed-loop stimulation of hypoglossal nerve in a dog model of upper airway obstruction. IEEE Trans Biomed Eng 47(7):919–925 source
Not checked in the free run.
- Premisecitation
Dhillon et al. demonstrated that a human amputee could control a robotic arm using signals from an intrafascicular electrode interface with sensory feedback.
“Dhillon et al. [30, 31] demonstrated the control of a robotic arm by a human amputee using signals recorded from an intrafascicular electrode interface while also incorporating sensory feedback.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [30] Dhillon GS, Horch KW (2005) Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng 13(4):468–472 source
Not checked in the free run.
- cites [31] Dhillon GS, Lawrence SM, Hutchinson DT, Horch KW (2004) Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs. J Hand Surg Am 29(4):605–615 source
Not checked in the free run.
- Classified as probably not a substantial claim. 32
- May combine two claims. 36
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisereasoningThe size of IC neural amplifiers is an additional consideration for portable or implantable applications, which require a highly miniaturized integrated system with small IC area and overall footprint.
“In addition to noise and power considerations, the size of IC neural amplifiers is an additional consideration when they are used for portable or implantable applications. Both applications require a highly miniaturized integrated system with a small IC area and overall system footprint.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenPower scheduling involves modulating the supply current of individual amplifier channels to reduce overall power consumption.
“Power scheduling involves modulating the supply current of individual amplifier channels to reduce the overall power consumption.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe front-end amplifier should have the lowest input-referred noise and higher gain than later stages because the input-referred noise of later stages is referred back to the electrodes through this amplifier's gain.
“This amplifier should have the lowest input-referred noise and higher gain than the subsequent stages, as the RTI noise of all subsequent stages are referred back to the electrodes through the gain of this amplifier [52].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [52] Harrison RR (2008) The design of integrated circuits to observe brain activity. Proc IEEE 96(7):1203–1216 source
Not checked in the free run.
Classified as probably not a substantial claim.
Premisenone givenNeural recording needs precise, low-noise amplifier systems to acquire and condition weak neural signals from electrode interfaces.
“Neural recording requires the use of precise, low-noise amplifier systems to acquire and condition the weak neural signals that are transduced through electrode interfaces.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningFor an electrode site with higher input noise, the corresponding front-end amplifier's power consumption can be reduced, and vice versa.
“For an electrode site that has higher input noise, the power consumption of the corresponding front-end amplifier can be reduced, and vice versa.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningNeural amplifiers require high gain and low noise because neural signals are small and span low to mid-range frequencies.
“Thus, neural amplifiers require high-gain and low-noise characteristics. Meeting these design requirements is technologically challenging and requires specialized design strategies.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningBecause shielding lead wires and amplifiers is not always practical, a high CMRR is an important and desired characteristic.
“Although electrical shielding would reduce this common-mode interference by reducing the induced current coupled into the amplifier, it is not always practical to shield the lead wires and the amplifiers. Therefore, a high CMRR is an important and desired characteristic.”
Quote in the paperNot a substantial claim- Rests on an assumption: Neural amplifiers typically have a common-mode rejection ratio between 70 and 120 dB, which is enough to suppress common-mode interference in most biopotential recordings.
May combine two claims.
PremisecitationStatic electric charges typically encountered can produce voltages above 25 kV, so proper ESD design and correct device handling procedures are still required.
“Although most ICs are designed to meet standard ESD specifications [3, 4], the static electric charges that are typically encountered may result in voltages higher than 25 kV [115], and hence proper ESD design of the ICs and correct device handling procedures are still required.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [3] ANSI/ESD S5.3.1-2009 (2009) Electrostatic discharge sensitivity testing—charged device model (CDM)—component level. In: Electrostatic Discharge Association source
Not checked in the free run.
- cites [4] ANSI/ESDA/JEDEC JS-001-2012 (2012) ESDA/JEDEC joint standard for electrostatic discharge sensitivity testing—human body model (HBM)—component level. Electrostatic Discharge Association
Not checked in the free run.
- cites [115] Sadiku MNO, Akujuobi CM (2004) Electrostatic discharge (ESD). IEEE Potentials 22(5):39–41 source
Not checked in the free run.
May combine two claims.
PremisereasoningCustom-designed neural recording ICs have advantages over commercially available systems, including miniaturized form factor, low weight, and low power consumption, which enable portable and implantable neurodevices.
“However, custom-designed neural recording ICs offer several prime advantages, including miniaturized form factor, low weight and low power consumption. These properties allow for portable and implantable neurodevices.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationAl-ashmouny et al. reported a 128-input channel neural recording IC in which only 16 inputs were selectively routed to the front-end amplifiers, achieving power and area reduction.
“For example, Al-ashmouny et al. reported a 128-input channel neural recording IC [2] with only 16 inputs selectively routed to the front-end amplifiers, therefore achieving power and area reduction.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [2] Al-ashmouny KM, Chang S, Yoon E (2012) A 4 µW/Ch analog front-end module with moderate inversion and power-scalable sampling operation for 3-D neural microsystems. IEEE Trans Biomed Circuits Syst 6(5):403–413 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationLopez et al. multiplexed 455 electrode inputs to 52 amplifiers.
“Another recent work by Lopez et al. [77] adopted the same method and multiplexed 455 electrode inputs to 52 amplifiers.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [77] Lopez CM, Andrei A, Mitra S, Welkenhuysen M, Eberle W, Bartic C, Puers R, Yazicioglu RF, Gielen GGE (2014) An implantable 455-active-electrode 52-channel CMOS neural probe. IEEE J Solid State Circuits 49(1):248–261 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisereasoningA trade-off between IC die size and on-chip functionality is generally required.
“A trade-off between the IC die size and functionality is generally required.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationMultiplexing a high-density electrode array to a smaller amplifier array is a widely used resource-sharing technique that relies on not all electrode sites providing useful information after implantation or on necessary information being obtainable from a small subset, although the useful subset is not known in advance.
“The first widely used technique consists of multiplexing a high-density electrode array to a much smaller amplifier array. This strategy leverages the fact that not all electrode sites may provide useful information after implantation [97, 101, 145] or that the necessary information can be obtained from a small subset of electrodes, although the useful electrode subset is not known a priori [118].”
Quote in the paperNot a substantial claim0 of 4 sources checked- cites [97] Olsson R, Wise K (2005) A three-dimensional neural recording microsystem with implantable data compression circuitry. IEEE J Solid State Circuits 40(12):2796–2804 source
Not checked in the free run.
- cites [101] Perlin GE, Sodagar AM, Wise KD (2006) Neural recording front-end designs for fully implantable neuroscience applications and neural prosthetic microsystems. In: Proceedings of international conference on IEEE engineering in medicine biology society, 2982–2985 source
Not checked in the free run.
- cites [145] Wise KD, Anderson DJ, Hetke JF, Kipke DR, Najafi K (2004) Wireless implantable microsystems: high-density electronic interfaces to the nervous system. Proc IEEE 92(1):76–97 source
Not checked in the free run.
- cites [118] Sanchez JC, Carmena JM, Lebedev MA, Nicolelis MAL, Harris JG, Principe JC (2004) Ascertaining the importance of neurons to develop better brain-machine interfaces. IEEE Trans Biomed Eng 51(6):943–953 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationChae et al. described a method to minimize the power-area product of a neural recording system by properly selecting the number of channels that share a single ADC.
“Chae et al. [16] described a method to minimize the power–area product of a neural recording system though the proper selection of the number of channels that share a single ADC.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [16] Chae M, Yang Z, Yuce M, Hoang L, Liu W (2009) A 128-channel 6 mW wireless neural recording IC with spike feature extraction and UWB transmitter. IEEE Trans Neural Syst Rehabil Eng 17(4):312–321 source
Not checked in the free run.
Classified as probably not a substantial claim.
Premisenone givenMiniaturized, low-power IC neural amplifiers are now used in emerging implantable neural prosthesis technologies.
“Furthermore, such miniaturized and low-power IC neural amplifiers are now being used in emerging implantable neural prosthesis technologies.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationNeural signals are generally smaller in amplitude than cardiac and muscle electrical signals and span frequencies from below 100 Hz to tens of kHz.
“They are generally smaller in amplitude than electrical signals of the heart and muscle, and they span low- (below 100 Hz) to mid-range (10 s of kHz) frequencies.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [143] Webster JG (ed) (1998) Medical instrumentation: application and design. Wiley, New york
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisereasoningA dynamic voltage folding circuit remapped the amplifiers' large output swing to fit the ADC's limited input swing.
“A dynamic voltage folding circuit then remapped the large output swing of the amplifiers to fit the limited input swing of the ADC.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningThe gate area optimization technique proposed by Ng and Xu must be used to reduce input-referred noise from flicker noise and the capacitor transformer effect for complementary input pairs.
“Thus, the gate area optimization technique proposed by Ng and Xu [92] must be used to reduce the input-referred noise due to flicker noise and capacitor transformer effect for the complimentary input pairs.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [92] Ng KA, Xu YP (2013) A compact, low input capacitance neural recording amplifier. IEEE Trans Biomed Circuits Syst 7(5):610–620 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenPseudo-resistors formed by PMOS transistors help establish proper DC negative feedback bias and, together with Cfb, define the low-side 3-dB cutoff frequency of the neural amplifier.
“The pseudo-resistors formed by PMOS transistors help establish a proper DC negative feedback bias and together with Cfb also define the low-side 3-dB cutoff frequency of the neural amplifier.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationWattanapanitch et al. proposed an NEF optimization scheme for low-voltage neural amplifiers using the folded cascode OTA, which was adopted in later studies.
“Wattanapanitch et al. [142] further proposed an NEF optimization scheme for low-voltage neural amplifiers implemented using the folded cascode OTA, which were adopted in later studies [103, 141].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [142] Wattanapanitch W, Fee M, Sarpeshkar R (2007) An energy-efficient micropower neural recording amplifier. IEEE Trans Biomed Circuits Syst 1(2):136–147 source
Not checked in the free run.
- cites [103] Qian C, Parramon J, Sanchez-Sinencio E (2011) A micropower low-noise neural recording front-end circuit for epileptic seizure detection. IEEE J Solid State Circuits 46(6):1392–1405 source
Not checked in the free run.
- cites [141] Wattanapanitch W, Sarpeshkar R (2011) A low-power 32-channel digitally programmable neural recording integrated circuit. IEEE Trans Biomed Circuits Syst 5(6):592–602 source
Not checked in the free run.
May combine two claims.
PremisecitationThe choice of front-end amplifier gain is influenced by the required application, whether CNS or PNS recording, and by the system's power supply.
“The choice of gain is influenced by the required application (CNS or PNS recording) and the system’s power supply [107].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [107] Rieger R, Schuettler M, Pal D, Clarke C, Langlois P, Taylor J, Donaldson N (2006) Very low-noise ENG amplifier system using CMOS technology. IEEE Trans Neural Syst Rehabil Eng 14(4):427–437 source
Not checked in the free run.
May combine two claims.
Premisenone givenThe OTA's thermal noise is inversely related to the bias current supplied to the input differential pair, while flicker noise is inversely proportional to the active gate area of that pair.
“The thermal noise of the OTA is inversely related to the amount of bias current supplied to the input differential pair of the OTA (M1 and M2), whereas the flicker noise component is inversely proportional to the active gate area of the input different pair.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisereasoningTo suppress noise from downstream signal processing stages, a high amplifier gain is desired and achieved by a high Cin/Cfb ratio, usually with a large Cin, but this increases silicon area and lowers input impedance.
“To suppress noise contributions from downstream signal processing stages, a high amplifier gain is desired and achieved by incorporating a high Cin/Cfb ratio (usually by using a large Cin), but at the expense of increased silicon area and lowered input impedance.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationContinued shrinking of fine-line CMOS processes has helped increase channel counts and add capabilities such as on-chip analog-to-digital conversion and digital radio transmission.
“The steady reduction in fine-line CMOS technologies has contributed to increased channel counts [6, 77] and expanded capabilities, such as on-chip analog-to-digital conversion [49, 156] and digital radio transmission [16, 67].”
Quote in the paperNot a substantial claim0 of 6 sources checked- cites [6] Aziz JNY, Abdelhalim K, Shulyzki R, Genov R, Bardakjian BL, Derchansky M, Serletis D, Carlen PL (2009) 256-Channel neural recording and delta compression microsystem with 3D electrodes. IEEE J Solid State Circuits 44(3):995–1005 source
Not checked in the free run.
- cites [77] Lopez CM, Andrei A, Mitra S, Welkenhuysen M, Eberle W, Bartic C, Puers R, Yazicioglu RF, Gielen GGE (2014) An implantable 455-active-electrode 52-channel CMOS neural probe. IEEE J Solid State Circuits 49(1):248–261 source
Not checked in the free run.
- cites [49] Han D, Zheng Y, Rajkumar R, Dawe G, Je M (2014) A 0.45 V 100-channel neural-recording IC with sub-µW/channel consumption in 0.18 µm CMOS. IEEE Trans Biomed Circuits Syst 7(6):735–746 source
Not checked in the free run.
- cites [156] Zou X, Liu L, Cheong JH, Yao L, Li P, Cheng MY, Goh WL, Rajkumar R, Dawe GS, Cheng KW, Je M (2013) A 100-channel 1-mW implantable neural recording IC. IEEE Trans Circuits Syst I 60(10):2584–2596 source
Not checked in the free run.
- cites [16] Chae M, Yang Z, Yuce M, Hoang L, Liu W (2009) A 128-channel 6 mW wireless neural recording IC with spike feature extraction and UWB transmitter. IEEE Trans Neural Syst Rehabil Eng 17(4):312–321 source
Not checked in the free run.
- cites [67] Lee SB, Lee H-M, Kiani M, Jow U-M, Ghovanloo M (2010) An inductively powered scalable 32-channel wireless neural recording system-on-a-chip for neuroscience applications. IEEE Trans Biomed Circuits Syst 4(6):360–371 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationRecent works reported that careful design of the OTA A1 makes low current consumption and low input-referred noise easily achievable.
“Recent works have also reported that by carefully designing the OTA A1, low current consumption and low input-referred noise are easily achievable [63, 141, 142, 156].”
Quote in the paperNot a substantial claim0 of 4 sources checked- cites [63] Johnson B, Molnar A (2013) An orthogonal current-reuse amplifier for multi-channel sensing. IEEE J Solid State Circuits 48(6):1487–1496 source
Not checked in the free run.
- cites [141] Wattanapanitch W, Sarpeshkar R (2011) A low-power 32-channel digitally programmable neural recording integrated circuit. IEEE Trans Biomed Circuits Syst 5(6):592–602 source
Not checked in the free run.
- cites [142] Wattanapanitch W, Fee M, Sarpeshkar R (2007) An energy-efficient micropower neural recording amplifier. IEEE Trans Biomed Circuits Syst 1(2):136–147 source
Not checked in the free run.
- cites [156] Zou X, Liu L, Cheong JH, Yao L, Li P, Cheng MY, Goh WL, Rajkumar R, Dawe GS, Cheng KW, Je M (2013) A 100-channel 1-mW implantable neural recording IC. IEEE Trans Circuits Syst I 60(10):2584–2596 source
Not checked in the free run.
May combine two claims.
PremisecitationThe most common front-end amplifier for IC neural recordings was first proposed by Najafi and Wise and later refined by Harrison to its present circuit.
“The most common front-end amplifier for IC neural recordings was first proposed by Najafi and Wise [89] and then further refined by Harrison [52] to its present circuit shown in Fig. 4.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [89] Najafi K, Wise K (1986) An implantable multielectrode array with on-chip signal processing. IEEE J Solid State Circuits 21(6):1035–1044 source
Not checked in the free run.
- cites [52] Harrison RR (2008) The design of integrated circuits to observe brain activity. Proc IEEE 96(7):1203–1216 source
Not checked in the free run.
May combine two claims.
PremisecitationAlthough input transistor gate areas are usually large to reduce flicker noise, that reduction is counteracted by an increased capacitance multiplying effect from the parasitic gate area.
“Although the gate areas of the input transistors are usually large to reduce the flicker noise component, the flicker noise reduction is contradicted by the increased capacitance multiplying effect contributed by the parasitic gate area [92].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [92] Ng KA, Xu YP (2013) A compact, low input capacitance neural recording amplifier. IEEE Trans Biomed Circuits Syst 7(5):610–620 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationNg and Xu proposed relaxing the area-gain trade-off by introducing additional shunt elements onto the negative feedback network.
“However, Ng and Xu proposed relaxing this area–gain trade-off by introducing additional shunt elements onto the negative feedback network [92].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [92] Ng KA, Xu YP (2013) A compact, low input capacitance neural recording amplifier. IEEE Trans Biomed Circuits Syst 7(5):610–620 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenThe current-reuse technique doubles the gate capacitance of the input differential pair.
“Although this current-reuse technique is a promising method for reducing the thermal noise component, it doubles the gate capacitance of the input differential pair.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationAl-ashmouny et al. reported an implementation in which the ADC supply voltage was scalable according to sampling rate, throttling power consumption.
“Similarly, Al-ashmouny et al. [2] reported an implementation where the supply voltage of the ADC was made scalable according to the sampling rate, throttling the power consumption.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [2] Al-ashmouny KM, Chang S, Yoon E (2012) A 4 µW/Ch analog front-end module with moderate inversion and power-scalable sampling operation for 3-D neural microsystems. IEEE Trans Biomed Circuits Syst 6(5):403–413 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationRecent studies have attempted to reduce silicon area by using smaller unit capacitors or by reducing amplifier gain.
“Recent studies have attempted to reduce the silicon area by using smaller unit capacitors or reducing the amplifier gain [77, 78].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [77] Lopez CM, Andrei A, Mitra S, Welkenhuysen M, Eberle W, Bartic C, Puers R, Yazicioglu RF, Gielen GGE (2014) An implantable 455-active-electrode 52-channel CMOS neural probe. IEEE J Solid State Circuits 49(1):248–261 source
Not checked in the free run.
- cites [78] Majidzadeh V, Schmid A, Leblebici Y (2011) Energy efficient low-noise neural recording amplifier with enhanced noise efficiency factor. IEEE Trans Biomed Circuits Syst 5(3):262–271 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationMuller et al. introduced the power efficiency factor, which accounts for both operating current and supply voltage and therefore provides a better comparison of amplifier performance.
“Recently, Muller et al. [86] introduced the power efficiency factor (PEF), which takes into account both the operating current and the supply voltage and therefore provides a better comparison of the amplifier’s performance.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [86] Muller R, Gambini S, Rabaey JM (2013) A 0.013 mm 2, 5 µW, DC-Coupled neural signal acquisition IC With 0.5 V supply. IEEE J Solid State Circuits 47(1):232–243 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
InterpretationcitationThe gate areas of the input differential pair must be appropriately sized according to the method described by Ng and Xu.
“Hence, the gate areas of the input differential pair must be appropriately sized according to the method described by Ng and Xu [92].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [92] Ng KA, Xu YP (2013) A compact, low input capacitance neural recording amplifier. IEEE Trans Biomed Circuits Syst 7(5):610–620 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenFront-end amplifier gains range from 200 to 10,000.
“Front-end amplifier gains range from 200 to 10,000.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisereasoningUnlike an operational amplifier, an OTA has no power-consuming output driver circuit because it does not need to bias resistive elements other than the high-resistance pseudo-resistor in the feedback network.
“As opposed to an operational amplifier (OpAmp), the OTA does not have a power-consuming output driver circuit, as it does not need to bias any resistive elements other than the high-resistance pseudo-resistor in the feedback network in Fig. 4.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationFor both the 2-stage Miller and symmetrical cascode OTAs, a significant part of total supply current is used for biasing and feedback stability at the second stages, leaving less current for the input differential stages and leading to higher NEF.
“For both types of OTAs, a significant part of the total supply current is only used for maintaining proper biasing and feedback stability at their second stages, leaving less current to bias their input differential stages and therefore leading to a higher NEF.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationAmplifier noise is typically designed to be lower than electrode noise and is maintained below 5 μVrms for CNS-recording amplifiers and below 1 μVrms for PNS-recording amplifiers.
“The noise introduced by the amplifier is typically designed to be lower than that introduced by the electrodes and, for a majority of neural applications, is maintained below 5 µVrms for amplifiers used to record CNS signals and less than 1 µVrms for PNS-recording amplifiers [76, 105].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [76] Loi D, Carboni C, Angius G, Angotzi GN, Barbaro M, Raffo L, Raspopovic S, Navarro X (2011) Peripheral neural activity recording and stimulation system. IEEE Trans Biomed Circuits Syst 5:368–379 source
Not checked in the free run.
- cites [105] Rieger R, Taylor J, Demosthenous A, Donaldson N, Langlois PJ (2003) Design of a low-noise preamplifier for nerve cuff electrode recording. IEEE J Solid State Circuits 38(8):1373–1379 source
Not checked in the free run.
May combine two claims.
Interpretationnone givenRestricting an amplifier's recording band to the frequencies of interest markedly lowers the amplifier's noise contribution and thereby raises recording quality.
“By constraining the amplifiers to record only within the bandwidths of interest, the noise contribution from the amplifier is significantly reduced and therefore improves the recording quality.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationHan et al. used 0.9 V and 0.45 V supply domains for the amplification stage and ADC, respectively.
“Finally, the chip reported by Han et al. [48] used 0.9 and 0.45 V supply domains for the amplification stage and ADC, respectively.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [48] Han D, Zheng Y, Rajkumar R, Dawe GS, Je M (2014) A 0.45 V 100-Channel neural-recording IC with sub-uW/channel consumption in 0.18 CMOS. IEEE Trans Biomed Circuits Syst 7(6):735–746 source
Not checked in the free run.
May combine two claims.
InterpretationcitationThe telescopic cascode OTA achieves the lowest NEF among the listed OTAs because all supply current is devoted to biasing the differential pair, allowing higher input gm and thus lower noise and NEF.
“The telescopic cascode OTA (Fig. 5c) achieves the lowest NEF among the listed OTAs, as all of the supply current is devoted to biasing the differential pair, allowing it to obtain a higher input gm (and hence lower noise and NEF) compared to the prior 2 OTAs.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationNeuroscience studies commonly place electrodes into specific cortical regions to record neural electrical activity.
“Typical neuroscience studies involve inserting electrodes [10, 90, 144] into specific regions of the cortex to acquire neural electrical activity.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [10] “Blackrock microsystems.” [Online]. Available: http://www.blackrockmicro.com/
Not checked in the free run.
- cites [90] “NeuroNexus Technologies.” [Online]. Available: http://www.neuronexustech.com
Not checked in the free run.
- cites [144] Wise KD, Angell JB, Starr A (1970) An integrated-circuit approach to extracellular microelectrodes. IEEE Trans Bio-med Eng 17(3):238–247 source
Not checked in the free run.
May combine two claims.
PremisecitationAdvances in IC design and fabrication now allow neural recording systems to include wireless telemetry for data and sometimes wireless power transfer.
“With continuous improvements in IC design and fabrication technology, IC neural recording systems can be now integrated with wireless telemetry for data and, in some cases, wireless power transfer [67, 94].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [67] Lee SB, Lee H-M, Kiani M, Jow U-M, Ghovanloo M (2010) An inductively powered scalable 32-channel wireless neural recording system-on-a-chip for neuroscience applications. IEEE Trans Biomed Circuits Syst 4(6):360–371 source
Not checked in the free run.
- cites [94] Ng KA, Xu L, Li X, Yen S, Je M, Xu YP, Tan TC (2012) An inductively powered CMOS multichannel bionic neural link for peripheral nerve function restoration. In: IEEE asian solid state circuits conference, 181–184 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationThe Neuropace system is a commercially available device that performs closed-loop neurostimulation to treat epilepsy.
“For example, the Neuropace system (California, USA) [91] is a commercially available device that performs closed-loop neurostimulation for the treatment of epilepsy.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [91] “Neuropace Inc.” [Online]. Available: http://www.neuropace.com/product/overview.html
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationDeep brain stimulation is especially effective for movement disorders including Parkinson's disease, dystonia and essential tremor.
“For example, deep brain stimulation (DBS) is particularly successful in treating movement disorders, such as Parkinson’s Disease, dystonia and essential tremor [5, 24, 83].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [5] Awan NR, Lozano A, Hamani C (2009) Deep brain stimulation: current and future perspectives. Neurosurg Focus 27:E2 source
Not checked in the free run.
- cites [24] Coffey RJ (2009) Deep brain stimulation devices: a brief technical history and review. Artif Organs 33(3):208–220 source
Not checked in the free run.
- cites [83] Miocinovic S, Somayajula S, Chitnis S, Vitek JL (2013) History, applications, and mechanisms of deep brain stimulation. JAMA Neurol 70(2):163–171 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationCNS-based neuroprostheses, or brain-machine interfaces, decode neural electrical activity to control robotic limbs or to stimulate muscles for restoring limb function.
“CNS-based neuroprostheses, or brain–machine interfaces (BMIs), are systems whereby neural electrical activities are decoded and used to control robotic limbs [76, 89, 105] or to stimulate muscles for restoring limb function [35].”
Quote in the paperNot a substantial claim0 of 4 sources checked- cites [76] Loi D, Carboni C, Angius G, Angotzi GN, Barbaro M, Raffo L, Raspopovic S, Navarro X (2011) Peripheral neural activity recording and stimulation system. IEEE Trans Biomed Circuits Syst 5:368–379 source
Not checked in the free run.
- cites [89] Najafi K, Wise K (1986) An implantable multielectrode array with on-chip signal processing. IEEE J Solid State Circuits 21(6):1035–1044 source
Not checked in the free run.
- cites [105] Rieger R, Taylor J, Demosthenous A, Donaldson N, Langlois PJ (2003) Design of a low-noise preamplifier for nerve cuff electrode recording. IEEE J Solid State Circuits 38(8):1373–1379 source
Not checked in the free run.
- cites [35] Ethier C, Oby ER, Bauman MJ, Miller LE (2012) Restoration of grasp following paralysis through brain-controlled stimulation of muscles. Nature 485(7398):368–371 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationClosed-loop DBS has been proposed to deliver adaptive neuromodulation synchronized to each patient's real-time pathological brain state.
“Closed-loop DBS has been proposed to provide synchronous adaptive neuromodulation based on real-time pathological brain states in each patient [15, 83, 121].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [15] Carron R, Chaillet A, Filipchuk A, Pasillas-Lépine W, Hammond C (2013) Closing the loop of deep brain stimulation. Front Syst Neurosci 7(2):112
Not checked in the free run.
- cites [83] Miocinovic S, Somayajula S, Chitnis S, Vitek JL (2013) History, applications, and mechanisms of deep brain stimulation. JAMA Neurol 70(2):163–171 source
Not checked in the free run.
- cites [121] Santos FJ, Costa RM, Tecuapetla F (2011) Stimulation on demand: closing the loop on deep brain stimulation. Neuron 72:197–198 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationSuch recording systems are often powered by small lightweight batteries or by wireless power transfer.
“Often, such systems are powered using miniaturized and light-weight battery packs [36] or wireless power transfer systems [135].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [36] Fan D, Rich D, Holtzman T, Ruther P, Dalley JW, Lopez A et al. (2011) A wireless multi-channel recording system for freely behaving mice and rats. PLoS One 6(7):e22033. doi: 10.1371/journal.pone.0022033 source
Not checked in the free run.
- cites [135] Thomas SJ, Harrison RR, Leonardo A, Reynolds MS (2012) A battery-free multichannel digital neural/EMG telemetry system for flying insects. IEEE Trans Biomed Circuits Syst 6(5):424–436 source
Not checked in the free run.
May combine two claims.
Interpretationnone givenPutting these modules on a single neuromodulation chip greatly reduces the form factor and simplifies implantation packaging.
“However, integration of these modules onto a single neuromodulation chip significantly decreases the form factor and simplifies the packaging required for implantation.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningThe added battery weight that rodents must carry often causes fatigue and shortens experiments.
“This adds additional weight that the rodent subjects must bear, which often leads to animal fatigue and limits the duration of experiments.”
Quote in the paperSubstantial claim- Rests on an assumption: Battery weight on rodents often leads to animal fatigue and limits experiment duration.
May combine two claims.
Interpretationnone givenSo far, IC-based PNS amplifier implementations have been reported only rarely, and existing technologies have generally been used only in acute experiments.
“Until now, there have been limited reports of IC-based PNS amplifier implementations, and existing technologies have generally only been applied to acute experiments.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationDBS also serves as an alternative treatment for pharmacoresistant epilepsy, pain control and psychiatric disorders.
“DBS is also an alternative treatment for pharmacoresistant epilepsy, pain control and psychiatric disorders [5].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [5] Awan NR, Lozano A, Hamani C (2009) Deep brain stimulation: current and future perspectives. Neurosurg Focus 27:E2 source
Not checked in the free run.
May combine two claims.
Interpretationnone givenCurrent DBS treatments use open-loop configurations and need periodic clinician visits to adjust stimulation for best efficacy.
“However, current DBS therapies are conducted in open-loop configurations and require periodic visits with a clinician to make adjustments for optimal stimulation efficacy.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationStudies of patients implanted with this device have shown sustained significant seizure reductions and improved quality of life.
“Recent studies on patients implanted with this device have exhibited significant reductions in seizures over a sustained period of time, and hence, the patients experience an improved quality of life [8].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [8] Bergey GK, Morrell MJ, Mizrahi EM, Goldman A, King-Stephens D, Nair D, Srinivasan S, Jobst B, Gross RE, Shields DC, Barkley G, Salanova V, Olejniczak P, Cole A, Cash SS, Noe K, Wharen R, Worrell G, Murro AM, Edwards J, Duchowny M, Spencer D, Smith M, Geller E, Gwinn R, Skidmore C, Eisenschenk S, Berg M, Heck C, Van Ness P, Fountain N, Rutecki P, Massey A, O’Donovan C, Labar D, Duckrow RB, Hirsch LJ, Courtney T, Sun FT, Seale CG (2015) Long-term treatment with responsive brain stimulation in adults with refractory partial seizures. Neurology 84(8):810–817 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe main aim of such studies is to learn how the activity of neuronal groups relates to sensation, behavior and cognition.
“The primary goal of such studies is to understand how the activities of groups of neurons are related to sensation, behavior and cognition [14, 117].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [14] Buzsáki G (2004) Large-scale recording of neuronal ensembles. Nat Neurosci 7(5):446–451 source
Not checked in the free run.
- cites [117] Sahin NT, Pinker S, Cash SS, Schomer D, Halgren E (2009) Sequential processing of lexical, grammatical, and phonological information within Broca’s area. Science 326:445–449 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningThese requirements demand more power-efficient ways to transmit recorded data off-chip.
“These needs require more power-efficient methods to send recorded data off-chip.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
InterpretationreasoningStudying naturally behaving animals demands recording systems that are highly miniaturized, small and light.
“This requires recording systems with a high degree of miniaturization, a small form factor and reduced weight.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationreasoningThe push to place more recording channels on one IC and to add more integrated features drives these design choices.
“These design choices are driven by the trend of packing increasingly higher numbers of recording channels on a single IC and the desire of researchers to have more integrated features.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Interpretationnone givenAlthough miniature wireless recording ICs could simplify BMI interfaces, major regulatory approvals are needed before they can be safely used in humans, especially for implantable applications.
“Although many of the miniature and lightweight wireless recording systems ICs [12, 20, 40, 84, 120, 136, 151] discussed in the earlier sections of this review would simplify the BMI interface, major regulatory approvals (FCC, FDA, IEC) are needed before these devices can be safely applied to human use (especially for implantable applications).”
Quote in the paperNot a substantial claim- Rests on an assumption: Major regulatory approvals (FCC, FDA, IEC) are required before wireless neural recording devices can be safely applied to human use.
May combine two claims.
PremisecitationMicera et al. used peripheral nerve stimulation to evoke graded sensory perceptions in a human amputee while decoding movement intention from residual muscle activity to actuate a robotic arm.
“Most recently, Micera et al. used peripheral nerve stimulation to evoke graded sensory perceptions in a human amputee subject while using the subject’s residual muscle activity to decode movement intention and actuate a robotic arm (Fig. 10) [82, 109].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [82] Micera S, Rossini PM, Rigosa J, Citi L, Carpaneto J, Raspopovic S, Tombini M, Cipriani C, Assenza G, Carrozza MC, Hoffmann K-P, Yoshida K, Navarro X, Dario P (2011) Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces. J Neuroeng Rehabil 8:53 source
Not checked in the free run.
- cites [109] Rossini PM, Micera S, Benvenuto A, Carpaneto J, Cavallo G, Citi L, Cipriani C, Denaro L, Denaro V, Di Pino G, Ferreri F, Guglielmelli E, Hoffmann KP, Raspopovic S, Rigosa J, Rossini L, Tombini M, Dario P (2010) Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiol 121(5):777–783 source
Not checked in the free run.
The paper relies on this without support.
Neural amplifiers typically have a common-mode rejection ratio between 70 and 120 dB, which is enough to suppress common-mode interference in most biopotential recordings.
“The CMRR of neural amplifiers typically ranges from 70 to 120 dB, which is sufficient for suppressing common-mode interference in most biopotential recordings.”
The paper relies on this without support.
Interfering noise sources are at least ten times larger than the neural signals of interest and can mask or corrupt the acquired neural signal.
“Such interfering noise sources are at least an order of magnitude larger than neural signals of interest and can potentially mask or corrupt the acquired neural signal.”
The authors state this as an assumption.
The transconductance of the NMOS and PMOS input devices is assumed to be equal.
“If the gm of the NMOS and PMOS is assumed the same, the gm of the amplifier increases by a factor of two for the same amount of biasing current.”
The paper relies on this without support.
Rodents can bear only limited weight, so portable neural recording systems for rodent studies must be small and low weight.
“Due to their small size, rodents can bear limited weight and, hence, portable neural recording systems for rodent studies must have a small form factor and low weight.”
The paper relies on this without support.
Battery weight on rodents often leads to animal fatigue and limits experiment duration.
“This adds additional weight that the rodent subjects must bear, which often leads to animal fatigue and limits the duration of experiments.”
The paper relies on this without support.
Major regulatory approvals (FCC, FDA, IEC) are required before wireless neural recording devices can be safely applied to human use.
“Although many of the miniature and lightweight wireless recording systems ICs [12, 20, 40, 84, 120, 136, 151] discussed in the earlier sections of this review would simplify the BMI interface, major regulatory approvals (FCC, FDA, IEC) are needed before these devices can be safely applied to human use (especially for implantable applications).”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The μV-level neural spike signal amplitudes and narrow bandwidths (200 Hz to 10 kHz) demand high-gain preamplification (typically of about 40 dB to 60 dB) and filtering prior to digitisation and processing, and are recorded in the presence of large common mode signals requiring high common-mode rejection ratio (CMRR).
“The μ V-level neural spike signal amplitudes and narrow bandwidths (200 Hz to 10 kHz) demand high-gain preamplification (typically of about 40 dB to 60 dB) and filtering prior to digitisation and processing [156], and are recorded in the presence of large common mode signals requiring high common-mode rejection ratio (CMRR) [157], [158].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [157]
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measuredThe folded cascode OTA presents a large output voltage swing, which makes it the natural choice for LV designs, though with a larger power consumption due to the additional current branches.
“Finally, the folded cascode OTA, presents a large output voltage swing, which makes it the natural choice for LV designs [157], though with a larger power consumption due to the additional current branches.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [157]
Section 2.5 calls the folded cascode OTA the natural choice for low-voltage neural front-end amplifiers, specifically those operating below 3 V and requiring low NEF and PEF values. It does not attribute that choice to a large output-voltage swing or state that additional current branches increase its power consumption. (LLM, conf=0.85)
Experimental — accuracy not yet measuredIntegrating complementary devices at the OTA input terminals increases their transconductance, and maximises the current efficiency, resulting in a lower NEF.
“Integrating complementary devices at the OTA input terminals increases their transconductance, and maximises the current efficiency, resulting in a lower NEF [157], [185].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [157]
Section 2.5 says complementary input pairs in a current-reuse amplifier double transconductance at the same bias current and reduce NEF by a factor of √2. It describes increased power efficiency, but does not establish that this arrangement maximises current efficiency. No page number is supplied in our copy. (LLM, conf=0.84)
Experimental — accuracy not yet measuredA common element of integrated recording systems is an operational transconductance amplifier (OTA), used as the active amplifying element and can be implemented using a variety of techniques.
“A common element of integrated recording systems is an operational transconductance amplifier (OTA), used as the active amplifying element and can be implemented using a variety of techniques [157], [167].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [157]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
A macaque experiment is cited as a human-patient BMI experiment
MinorThe paper includes study [35] in a list of BMI experiments with human patients, but earlier describes that study as using a macaque model.
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
“For example, Miller et al. [35] used a BMI interface to drive stimulation of hand muscles to restore compromised grasping ability in a macaque model.”
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · see citing works
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · see citing works
Leakage current mechanisms and leakage reduction techniques in deep-submicrometer CMOS circuits
Roy, K., Mukhopadhyay, S. C., & Mahmoodi, H. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2002.808156 · Cited by 2,378 · see citing works
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · see citing works
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · see citing works
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,849 · see citing works
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · see citing works
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695 · see citing works
Neural population dynamics during reaching
Churchland, M. M., Cunningham, J. P., Kaufman, M. T., Foster, J. D., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2012) · Nature · doi:10.1038/nature11129 · Cited by 1,636 · see citing works
Evans, D. C., Schott, R. K., Larson, D. W., Brown, C. M., & Ryan, M. J. (2014) · Nature Communications · doi:10.1038/ncomms4289 · Cited by 942 · see citing works
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782 · see citing works
Bowman, K. A., Duvall, S. G., & MEINDL, J. D. (2002) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.982424 · Cited by 747 · see citing works
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R. R., Watkins, P., Kier, R. J., Lovejoy, R. O., Black, D., Normann, R. A., & Solzbacher, F. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696288 · Cited by 731 · see citing works
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656 · see citing works
Long-term treatment with responsive brain stimulation in adults with refractory partial seizures
Bergey, G. K., Morrell, M. J., Mizrahi, E. M., Goldman, A., King-Stephens, D., Nair, D., Srinivasan, S., Jobst, B., Gross, R. E., Shields, D. C., et al. (2015) · Neurology · doi:10.1212/wnl.0000000000001280 · Cited by 634 · see citing works
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577 · see citing works
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573 · see citing works
How advances in neural recording affect data analysis
Stevenson, I. H., & Kording, K. P. (2011) · Nature Neuroscience · doi:10.1038/nn.2731 · Cited by 564 · see citing works
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · see citing works
(2006) · The International Series in Engineering and Computer Science · doi:10.1007/b135984 · Cited by 511 · see citing works
History, Applications, and Mechanisms of Deep Brain Stimulation
Miocinovic, S., Somayajula, S., Chitnis, S., & Vitek, J. L. (2013) · JAMA Neurology · doi:10.1001/2013.jamaneurol.45 · Cited by 496 · see citing works
Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E. (2012) · Nature · doi:10.1038/nature10987 · Cited by 485 · see citing works
High-quality recording of bioelectric events
van Rijn, A. C. M., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 455 · see citing works
Sequential Processing of Lexical, Grammatical, and Phonological Information Within Broca’s Area
Sahin, N. T., Pinker, S., Cash, S. S., Schomer, D., & Halgren, E. (2009) · Science · doi:10.1126/science.1174481 · Cited by 452 · see citing works
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441 · see citing works
High-quality recording of bioelectric events
van Rijn, A. C. M., Peper, A., & Grimbergen, C. A. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441961 · Cited by 429 · see citing works
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · see citing works
Effects and Mechanisms of Wakefulness on Local Cortical Networks
Constantinople, C. M., & Bruno, R. M. (2011) · Neuron · doi:10.1016/j.neuron.2011.02.040 · Cited by 387 · see citing works
Zannad, F. M., Ferrari, G. M. D., Tuinenburg, A. E., Wright, D. J., Brugada, J., Butter, C., Klein, H., Stolen, C., Meyer, S., Steín, K. M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu345 · Cited by 380 · see citing works
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369 · see citing works
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · see citing works
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338 · see citing works
The Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330 · see citing works
Batteries used to power implantable biomedical devices
Bock, D. C., Marschilok, A. C., Takeuchi, K. J., & Takeuchi, E. S. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.03.057 · Cited by 319 · see citing works
An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Borton, D. A., Yin, M., Aceros, J. C., & Nurmikko, A. V. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026010 · Cited by 318 · see citing works
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310 · see citing works
Chen, W., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M., Lin, C., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., et al. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284346 · Cited by 279 · see citing works
An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264 · see citing works
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263 · see citing works
A three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245 · see citing works
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220 · see citing works
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218 · see citing works
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215 · see citing works
Real-time control of a prosthetic hand using human electrocorticography signals: Technical note
Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2011) · Journal of Neurosurgery · doi:10.3171/2011.1.jns101421 · Cited by 208 · see citing works
Decoding Continuous and Discrete Motor Behaviors Using Motor and Premotor Cortical Ensembles
Hatsopoulos, N. G., Joshi, J., & O'Leary, J. G. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01245.2003 · Cited by 202 · see citing works
Analog Circuit Design in Nanoscale CMOS Technologies
Lewyn, L. L., Ytterdal, T., Wulff, C., & Martin, K. W. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2024663 · Cited by 200 · see citing works
HermesE: A 96-Channel Full Data Rate Direct Neural Interface in 0.13 $\mu$m CMOS
Gao, H., Walker, R. M., Nuyujukian, P., Makinwa, K. A. A., Shenoy, K. V., Murmann, B., & Meng, T. H. Y. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185338 · Cited by 189 · see citing works
256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes
Aziz, J. N. Y., Abdelhalim, K., Shulyzki, R., Genov, R., Bardakjian, B. L., Derchansky, M., Serletis, D., & Carlen, P. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010997 · Cited by 184 · see citing works
A wireless multi-channel neural amplifier for freely moving animals
Szuts, T. A., Fadeyev, V., Kachiguine, S., Sher, A., Grivich, M., Agrochão, M., Hottowy, P., Dąbrowski, W., Lubenov, E. V., Siapas, A. G., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2730 · Cited by 183 · see citing works
OlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181 · see citing works
Deep Brain Stimulation Devices: A Brief Technical History and Review
Coffey, R. J. (2009) · Artificial Organs · doi:10.1111/j.1525-1594.2008.00620.x · Cited by 178 · see citing works
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175 · see citing works
Self-citationEnergy Efficient Low-Noise Neural Recording Amplifier With Enhanced Noise Efficiency Factor
Majidzadeh, V., Schmid, A., & Leblebici, Y. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078815 · Cited by 165 · see citing works
A 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications
Yin, M., Borton, D. A., Aceros, J. C., Patterson, W. R., & Nurmikko, A. V. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2255874 · Cited by 161 · see citing works
Miranda, H. C., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H. Y. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2044573 · Cited by 161 · see citing works
A Versatile Integrated Circuit for the Acquisition of Biopotentials
Harrison, R. R. (2007) · 2007 IEEE Custom Integrated Circuits Conference · doi:10.1109/cicc.2007.4405694 · Cited by 156 · see citing works
Nano‐CMOS Circuit and Physical Design
Wong, B. P., Mittal, A., Cao, Y. K., & Starr, G. W. (2004) · Wiley eBooks · doi:10.1002/0471653829 · Cited by 154 · see citing works
ESD: a pervasive reliability concern for IC technologies
Duvvury, C., & Amerasekera, A. (1993) · Proceedings of the IEEE · doi:10.1109/5.220901 · Cited by 148 · see citing works
Han, D., Zheng, Y., Rajkumar, R., Dawe, G. S., & Je, M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298860 · Cited by 147 · see citing works
A Low-Power 32-Channel Digitally Programmable Neural Recording Integrated Circuit
Wattanapanitch, W., & Sarpeshkar, R. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2163404 · Cited by 146 · see citing works
A Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection
Qian, C., Parramon, J., & Sanchez-Sinencio, E. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2126370 · Cited by 145 · see citing works
A Wireless Multi-Channel Recording System for Freely Behaving Mice and Rats
Fan, D., Rich, D., Holtzman, T., Ruther, P., Dalley, J. W., Lopez, A., Rossi, M. A., Barter, J. W., Salas-Meza, D., Herwik, S., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022033 · Cited by 143 · see citing works
Lee, J., Rhew, H.-G., Kipke, D. R., & Flynn, M. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2052403 · Cited by 140 · see citing works
A 0.013mm2 5μW DC-coupled neural signal acquisition IC with 0.5V supply
Muller, R., Gambini, S., & Rabaey, J. M. (2011) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2011.5746328 · Cited by 138 · see citing works
HermesB: A Continuous Neural Recording System for Freely Behaving Primates
Santhanam, G., Linderman, M. D., Gilja, V., Afshar, A., Ryu, S. I., Meng, T. H. Y., & Shenoy, K. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895753 · Cited by 134 · see citing works
A 100-Channel 1-mW Implantable Neural Recording IC
Zou, X., Liu, L., Cheong, J. H., Yao, L., Li, P., Cheng, M.-Y., Goh, W. L., Rajkumar, R., Dawe, G. S., Cheng, K.-W., et al. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2013.2249175 · Cited by 132 · see citing works
HermesC: Low-Power Wireless Neural Recording System for Freely Moving Primates
Chestek, C. A., Gilja, V., Nuyujukian, P., Kier, R. J., Solzbacher, F., Ryu, S. I., Harrison, R. R., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023293 · Cited by 130 · see citing works
Abdelhalim, K., Jafari, H. M., Kokarovtseva, L., Velazquez, J. L. P., & Genov, R. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2272952 · Cited by 124 · see citing works
A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123 · see citing works
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121 · see citing works
A Battery-Free Multichannel Digital Neural/EMG Telemetry System for Flying Insects
Thomas, S. J., Harrison, R. R., Leonardo, A., & Reynolds, M. S. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2222881 · Cited by 117 · see citing works
Perelman, Y., & Ginosar, R. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883732 · Cited by 116 · see citing works
Ascertaining the Importance of Neurons to Develop Better Brain-Machine Interfaces
Sanchez, J. C., Carmena, J. M., Lebedev, M. A., Nicolelis, M. A. L., Harris, J. G., & Principe, J. C. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827061 · Cited by 111 · see citing works
Closing the loop of deep brain stimulation
Carron, R., Chaillet, A., Filipchuk, A., Pasillas-Lépine, W., & Hammond, C. (2013) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2013.00112 · Cited by 109 · see citing works
Beuter, A., Lefaucheur, J.-P., & Modolo, J. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.01.006 · Cited by 107 · see citing works
An intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107 · see citing works
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · see citing works
Rhew, H.-G., Jeong, J., Fredenburg, J. A., Dodani, S., Patil, P. G., & Flynn, M. P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2346779 · Cited by 104 · see citing works
Rodriguez-Perez, A., Ruiz-Amaya, J., Delgado-Restituto, M., & Rodriguez-Vazquez, Á. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2187352 · Cited by 103 · see citing works
Micera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100 · see citing works
Wireless Neural/EMG Telemetry Systems for Small Freely Moving Animals
Harrison, R. R., Fotowat, H., Chan, R., Kier, R. J., Olberg, R. M., Leonardo, A. M., & Gabbiani, F. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2131140 · Cited by 92 · see citing works
Low-Power Circuits for Brain–Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Arfin, S. K., Rapoport, B. I., Mandal, S., Baker, M. W., Fee, M. S., Musallam, S., & Andersen, R. A. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003198 · Cited by 91 · see citing works
Fotowat, H., Harrison, R. R., & Krahe, R. (2013) · Journal of Neuroscience · doi:10.1523/jneurosci.0998-13.2013 · Cited by 88 · see citing works
Deep brain stimulation: current and future perspectives
Awan, N. R., Lozano, A., & Hamani, C. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0982 · Cited by 83 · see citing works
A Compact, Low Input Capacitance Neural Recording Amplifier
Ng, K. A., & Xu, Y. P. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2280066 · Cited by 81 · see citing works
Self-citationWireless multi-channel single unit recording in freely moving and vocalizing primates
Roy, S., & Wang, X. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.09.004 · Cited by 81 · see citing works
Olofsson, P. S., Levine, Y. A., Caravaca, A., Chavan, S. S., Pavlov, V. A., Faltys, M., & Tracey, K. J. (2015) · Bioelectronic Medicine · doi:10.15424/bioelectronmed.2015.00006 · Cited by 81 · see citing works
An Orthogonal Current-Reuse Amplifier for Multi-Channel Sensing
Johnson, B., & Molnar, A. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2257478 · Cited by 80 · see citing works
Design of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78 · see citing works
Role of Prefrontal Cortex in Conscious Visual Perception
Libedinsky, C., & Livingstone, M. S. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.3620-10.2011 · Cited by 77 · see citing works
Upshaw, B., & Sinkjaer, T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681183 · Cited by 74 · see citing works
Yoo, H., & Hoof, C. A. V. (2010) · Integrated circuits and systems · doi:10.1007/978-1-4419-6597-4 · Cited by 72 · see citing works
A freely-moving monkey treadmill model
Foster, J. D., Nuyujukian, P., Freifeld, O., Gao, H., Walker, R. M., Ryu, S. I., Meng, T. H. Y., Murmann, B., Black, M. J., & Shenoy, K. V. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046020 · Cited by 71 · see citing works
Jia, X., Koenig, M. A., Zhang, X., Zhang, J., Chen, T., & Chen, Z. (2007) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.02.021 · Cited by 70 · see citing works
Chronic multi-electrode neural recording in free-roaming monkeys
Eliades, S. J., & Wang, X. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.04.029 · Cited by 69 · see citing works
Delivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68 · see citing works
Long‐term effects of axotomy on neural activity during cat locomotion.
Gordon, T., Hoffer, J. A., Jhamandas, J., & Stein, R. B. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013283 · Cited by 65 · see citing works
EnerCage: A Smart Experimental Arena With Scalable Architecture for Behavioral Experiments
Jow, U.-M., McMenamin, P., Kiani, M., Manns, J. R., & Ghovanloo, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2278180 · Cited by 62 · see citing works
Stimulation on Demand: Closing the Loop on Deep Brain Stimulation
Santos, F. J., Costa, R. M., & Tecuapetla, F. (2011) · Neuron · doi:10.1016/j.neuron.2011.10.004 · Cited by 60 · see citing works
An Area-Efficient Noise-Adaptive Neural Amplifier in 130 nm CMOS Technology
Chaturvedi, V., & Amrutur, B. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2178731 · Cited by 60 · see citing works
A 0.45V 100-channel neural-recording IC with sub-µW/channel consumption in 0.18µm CMOS
Han, D., Zheng, Y., Rajkumar, R., Dawe, G. S., & Je, M. (2013) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2013.6487739 · Cited by 59 · see citing works
A cortical–spinal prosthesis for targeted limb movement in paralysed primate avatars
Shanechi, M. M., Hu, R. C., & Williams, Z. M. (2014) · Nature Communications · doi:10.1038/ncomms4237 · Cited by 59 · see citing works
Estimation of Bladder Volume From Afferent Neural Activity
Mendez, A., Sawan, M., Minagawa, T., & Wyndaele, J.-J. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2266899 · Cited by 57 · see citing works
Very Low-Noise ENG Amplifier System Using CMOS Technology
Rieger, R., Schuettler, M., Pal, D., Clarke, C., Langlois, P., Taylor, J., & Donaldson, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.886731 · Cited by 57 · see citing works
Implantable neurotechnologies: electrical stimulation and applications
Nag, S., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1442-0 · Cited by 55 · see citing works
Self-citationGreenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1429-x · Cited by 53 · see citing works
Self-citation800 nW 43 nV/√Hz neural recording amplifier with enhanced noise efficiency factor
Liu, L., Zou, X., Goh, W. L., Ramamoorthy, R., Dawe, G. S., & Je, M. (2012) · Electronics Letters · doi:10.1049/el.2012.0685 · Cited by 51 · see citing works
Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff
Schuettler, M., Donaldson, N., Seetohul, V., & Taylor, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036016 · Cited by 50 · see citing works
Energy-Efficient Multi-Mode Compressed Sensing System for Implantable Neural Recordings
Suo, Y., Zhang, J., Xiong, T., Chin, P. S., Etienne-Cummings, R., & Tran, T. D. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2359180 · Cited by 47 · see citing works
32.9 nV/rt Hz ${-}$60.6 dB THD Dual-Band Micro-Electrode Array Signal Acquisition IC
Guo, J., Yuan, J., Huang, J., Law, J. K.-Y., Yeung, C.-K., & Chan, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185590 · Cited by 45 · see citing works
Within-die process variations: how accurately can they be statistically modeled?
Hargreaves, B., Hult, H., & Reda, S. (2008) · doi:10.5555/1356802.1356930 · Cited by 45 · see citing works
Yoshida, K., Kurstjens, G. A. M., & Hennings, K. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.08.005 · Cited by 43 · see citing works
A Digitally Assisted, Signal Folding Neural Recording Amplifier
Chen, Y., Basu, A., Liu, L., Zou, X., Rajkumar, R., Dawe, G. S., & Je, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2288680 · Cited by 43 · see citing works
A 1-V 60-µW 16-channel interface chip for implantable neural recording
Liew, W.-S., Zou, X., Yao, L., & Lian, Y. (2009) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2009.5280795 · Cited by 43 · see citing works
Peripheral Neural Activity Recording and Stimulation System
Loi, D., Carboni, C., Angius, G., Angotzi, G. N., Barbaro, M., Raffo, L., Raspopovic, S., & Navarro, X. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2123097 · Cited by 42 · see citing works
Within-die process variations: How accurately can they be statistically modeled?
Hargreaves, B., Hult, H., & Reda, S. (2008) · Asia and South Pacific Design Automation Conference (ASP-DAC) · doi:10.1109/aspdac.2008.4484007 · Cited by 39 · see citing works
A monolithic signal processor for a neurophysiological telemetry system
DORMAN, M. G., PRISBE, M., & MEINDL, J. D. (1985) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1985.1052457 · Cited by 36 · see citing works
Halbach, M., Hickethier, T., Madershahian, N., Reuter, H., Brandt, M. C., Hoppe, U. C., & Müller‐Ehmsen, J. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000586 · Cited by 36 · see citing works
A closed-loop compressive-sensing-based neural recording system
Zhang, J., Mitra, S., Suo, Y., Cheng, A., Xiong, T., Michon, F., Welkenhuysen, M., Kloosterman, F., Chin, P. S., Hsiao, S., et al. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036005 · Cited by 33 · see citing works
Ng, K. A., & Xu, Y. P. (2015) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2015.7062998 · Cited by 33 · see citing works
Self-citationA 430nW 64nV/vHz current-reuse telescopic amplifier for neural recording applications
Song, S., Rooijakkers, M. J., Harpe, P., Rabotti, C., Mischi, M., van Roermund, A. H. M., & Cantatore, E. (2013) · 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2013.6679704 · Cited by 33 · see citing works
Integrated CMOS Amplifier for ENG Signal Recording
Uranga, A., Navarro, X., & Barniol, N. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.834253 · Cited by 33 · see citing works
Low-Power Circuits for Brain-Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Rapoport, B. I., Arfin, S. K., Baker, M., Mandal, S., Fee, M. S., Musallam, S., & Andersen, R. A. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.378505 · Cited by 31 · see citing works
Design of an Adaptive Interference Reduction System for Nerve-Cuff Electrode Recording
Demosthenous, A., Taylor, J. T., Triantis, I. F., Rieger, R., & Donaldson, N. (2004) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2004.823677 · Cited by 31 · see citing works
Perlin, G. E., Sodagar, A. M., & Wise, K. D. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260193 · Cited by 30 · see citing works
Al-Ashmouny, K. M., Chang, S.-I., & Yoon, E. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2218105 · Cited by 28 · see citing works
Chew, K. W., Chew, K. W., Yeo, K. S., & Chu, S. ‐. (2004) · IEE Proceedings - Circuits Devices and Systems · doi:10.1049/ip-cds:20040991 · Cited by 27 · see citing works
Wong, B. P., Mittal, A., Starr, G. W., Zach, F. X., Moroz, V., & Kahng, A. B. (2008) · Cited by 26 · see citing works
Sadiku, M. N. O., & Akujuobi, C. M. (2004) · IEEE Potentials · doi:10.1109/mp.2004.1301247 · Cited by 24 · see citing works
Greenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1452-6 · Cited by 23 · see citing works
Self-citationClosed-loop stimulation of hypoglossal nerve in a dog model of upper airway obstruction
Sahin, M., Durand, D. H., & Haxhiu, M. A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846686 · Cited by 22 · see citing works
A battery-free multi-channel digital neural/EMG telemetry system for flying insects
Thomas, S. J., Harrison, R. R., Leonardo, A. M., & Reynolds, M. S. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107769 · Cited by 21 · see citing works
3-D System-on-System (SoS) Biomedical-Imaging Architecture for Health-Care Applications
Lee, S., Kavehei, O., Hong, Y., Cho, T. W., You, Y., Cho, K.-R., & Eshraghian, K. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2079330 · Cited by 21 · see citing works
Wireless Headstage for Neural Prosthetics
Morizio, J., Irazoqui, P. P., Go, V., & Parmentier, J. C. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419647 · Cited by 21 · see citing works
Nano‐CMOS Design for Manufacturabililty
Wong, B. P., Zach, F. X., Moroz, V., Mittal, A., Starr, G. W., & Kahng, A. B. (2008) · Wiley eBooks · doi:10.1002/9780470382820 · Cited by 20 · see citing works
Schuettler, M., Seetohul, V., Rijkhoff, N. J. M., Moeller, F. V., Donaldson, N., & Taylor, J. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6090847 · Cited by 19 · see citing works
Implantable stimulator and recording device for artificial prosthesis control
Sacristán, J., & Osés, M. T. (2007) · Microelectronics Journal · doi:10.1016/j.mejo.2007.10.003 · Cited by 18 · see citing works
Combining wireless neural recording and video capture for the analysis of natural gait
Foster, J. D., Freifeld, O., Nuyujukian, P., Ryu, S. I., Black, M. J., & Shenoy, K. V. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910623 · Cited by 15 · see citing works
Li, L.-J., Zhang, J., Zhang, F., Lineaweaver, W. C., Chen, T.-Y., & Chen, Z.-W. (2005) · Microsurgery · doi:10.1002/micr.20159 · Cited by 14 · see citing works
Keyes, R. W. (2008) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2008.923058 · Cited by 12 · see citing works
A Bionic Neural Link for peripheral nerve repair
Xu, Y. P., Yen, S.-C., Ng, K. A., Liu, X., & Tan, T. C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346184 · Cited by 11 · see citing works
Self-citationCompact wireless neural recording system for small animals using silicon-based probe arrays
Ruther, P., Holzhammer, T., Herwik, S., Rich, P. D., Dalley, J. W., Paul, O., & Holtzman, T. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090575 · Cited by 11 · see citing works
Is a New Paradigm for Nanoscale Analog CMOS Design Needed?
Lewyn, L. L., & Williams, N. R. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2083810 · Cited by 10 · see citing works
Ng, K. A., Liu, X., Zhao, J., Xuchuan, L., Yen, S.-C., Je, M., Xu, Y. P., & Tan, T. C. (2012) · 2012 IEEE Asian Solid State Circuits Conference (A-SSCC) · doi:10.1109/ipec.2012.6522655 · Cited by 9 · see citing works
Self-citationGuo, L., Clements, I. P., Li, D., Bellamkonda, R. V., & DeWeerth, S. P. (2010) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2010.5709604 · Cited by 8 · see citing works
10-CHANNEL VERY LOW NOISE ENG AMPLIFIER SYSTEM USING CMOS TECHNOLOGY
Rieger, R., Pal, D., Taylor, J. T., Clarke, C., Langlois, P. J., & Donaldson, N. (2005) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2005.1464696 · Cited by 7 · see citing works
Basu, K. P. (2003) · IEEE Potentials · doi:10.1109/mp.2003.1197881 · Cited by 6 · see citing works
The Electrostatic Discharge Phenomenon
(2009) · Electrostatic Discharge · doi:10.1002/9780470495070.ch1 · Cited by 6 · see citing works
Al-Ashmouny, K. M., Chang, S.-I., & Yoon, E. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107712 · Cited by 6 · see citing works
Rozman, J., Zorko, B., Bunc, M., Mikac, U., & Tegou, E. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/4/309 · Cited by 5 · see citing works
A Gate Leakage Feedback Element in an Adaptive Amplifier Application
Berge, H. K. O., & Hafliger, P. D. (2008) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2007.910761 · Cited by 5 · see citing works
An intrafascicular electrode with integrated amplifiers for peripheral nerve recording
Ng, K. A., Cutrone, A., Bossi, S., Nag, S., Delgado-Martínez, I., Sheshadri, S., Poulard, C. A., Xu, Y. P., Yen, S., & Thakor, N. V. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146642 · Cited by 4 · see citing works
Self-citationSome Recent Developments in the Design of Biopotential Amplifiers for ENG Recording Systems
Taylor, J. T., Masanotti, D., Seetohul, V., & Hao, S. (2006) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2006.342514 · Cited by 3 · see citing works
Whole sensory nerve recordings with spiral nerve cuff electrode
Sinjar, T., Hinge, B., Jorgensen, A., Jensen, M. L., & Haugland, M. (1992) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1992.5761815 · Cited by 2 · see citing works
1/f Noise Performance of Advanced Cmos Devices
von Haartman, M., & Östling, M. (2007) · Springer eBooks · doi:10.1007/978-1-4020-5910-0_4 · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 3
- Gray PR, Hurst PJ, Meyer RG, Lewis SH (2009) Analysis and design of analog integrated circuits. 5th edn. Wiley, US
- IEEE C95.1-2005 (2006) IEEE Standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3–300 GHz. In: IEEE Std C95.1-2005 (Revision of IEEE Std C95.1-1991), pp 0_1–238
- Wolf PD (2008) Thermal considerations for the design of an implanted cortical brain—machine interface (BMI). In: Indwelling neural implants, 1st ed. CRC Press, Boca Raton, 63–86
Cited by
Sorted by citations
Lončar-Turukalo, T., Zdravevski, E., da Silva, J. M., Chouvarda, I., & Trajkovik, V. (2019) · Journal of Medical Internet Research · doi:10.2196/14017 · Cited by 240 · see citing works
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175 · see citing works
Self-citationTranslational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 143 · see citing works
Human motor decoding from neural signals: a review
Tam, W.-K., Wu, T., Zhao, Q., Keefer, E. W., & Yang, Z. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0022-z · Cited by 100 · see citing works
Putzeys, J., Raducanu, B. C., Carton, A., Ceulaer, J. D., Karsh, B., Siegle, J. H., Helleputte, N. V., Harris, T. D., Dutta, B., Musa, S., et al. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2943077 · Cited by 72 · see citing works
Translational Neuroelectronics
Jastrzebska‐Perfect, P., Chowdhury, S., Spyropoulos, G. D., Zhao, Z., Cea, C., Gelinas, J. N., & Khodagholy, D. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909165 · Cited by 64 · see citing works
Implantable neurotechnologies: electrical stimulation and applications
Nag, S., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1442-0 · Cited by 55 · see citing works
Self-citationGreenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1429-x · Cited by 53 · see citing works
Self-citationBergmeister, K. D., Vujaklija, I., Muceli, S., Sturma, A., Hruby, L. A., Prahm, C., Riedl, O., Salminger, S., Manzano-Szalai, K., Aman, M., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00421 · Cited by 52 · see citing works
Electrophysiology Read-Out Tools for Brain-on-Chip Biotechnology
Forró, C., Caron, D., Angotzi, G. N., Gallo, V., Berdondini, L., Santoro, F., Palazzolo, G., & Panuccio, G. (2021) · Micromachines · doi:10.3390/mi12020124 · Cited by 50 · see citing works
Sampling rate, signal bandwidth and related pitfalls in EEG analysis
Weiergräber, M., Papazoglou, A., Broich, K., & Müller, R. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.05.010 · Cited by 48 · see citing works
Developing Next-Generation Brain Sensing Technologies—A Review
Robinson, J. T., Xie, C., Pohlmeyer, E. A., Gather, M. C., Kemere, C. T., Kitching, J. E., Malliaras, G. G., Marblestone, A. H., Shepard, K. L., & Stieglitz, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2931159 · Cited by 44 · see citing works
Peripheral Focused Ultrasound Neuromodulation (pFUS)
Cotero, V. E., Miwa, H., Graf, J. F., Ashe, J. M., Loghin, E., Carlo, D. D., & Puleo, C. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108721 · Cited by 39 · see citing works
Design of high gain, high bandwidth neural amplifier IC considering noise-power trade-off
Laskar, N. M., Guha, K., Nath, S., Chanda, S., Baishnab, K. L., Paul, P. K., & Rao, K. S. (2018) · Microsystem Technologies · doi:10.1007/s00542-018-4142-5 · Cited by 33 · see citing works
Towards miniaturized closed-loop optogenetic stimulation devices
Edward, E. S., Kouzani, A. Z., & Tye, S. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7d62 · Cited by 25 · see citing works
Sensing and Control for Prosthetic Hands in Clinical and Research Applications
Osborn, L. E., Iskarous, M. M., & Thakor, N. V. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814659-0.00022-9 · Cited by 25 · see citing works
Self-citationGreenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1452-6 · Cited by 23 · see citing works
Self-citationIn Vivo Penetrating Microelectrodes for Brain Electrophysiology
Erofeev, A., Antifeev, I., Bolshakova, A. V., Борисович, Б. И., & Власова, О. Л. (2022) · Sensors · doi:10.3390/s22239085 · Cited by 24 · see citing works
Noise Efficient Integrated Amplifier Designs for Biomedical Applications
Simmich, S., Bahr, A., & Rieger, R. (2021) · Electronics · doi:10.3390/electronics10131522 · Cited by 23 · see citing works
Soft, wireless and subdermally implantable recording and neuromodulation tools
Cai, L., & Gutruf, P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe805 · Cited by 22 · see citing works
Martínez, S., Veirano, F., Constandinou, T. G., & Silveira, F. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3228895 · Cited by 20 · see citing works
Thukral, A., Ershad, F., Enan, N., Rao, Z., & Yu, C. (2018) · IEEE Nanotechnology Magazine · doi:10.1109/mnano.2017.2781290 · Cited by 19 · see citing works
Bi-directional brain interfacing instrumentation
Herron, J. A., Stanslaski, S. R., Chouinard, T., Corey, R., Denison, T., & Orser, H. D. (2018) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2018.8409795 · Cited by 17 · see citing works
Tasneem, N. T., & Mahbub, I. (2021) · Electronics · doi:10.3390/electronics10050590 · Cited by 17 · see citing works
A Miniature Low-Power Multi-Biomarker-Based Brain Sensor for Closed-Loop DBS
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2686642 · Cited by 17 · see citing works
Maiolo, L., Polese, D., & Convertino, A. (2019) · Advances in Physics X · doi:10.1080/23746149.2019.1664319 · Cited by 18 · see citing works
A low power, low noise amplifier for neural signal amplification in SCL 180nm
Baishnab, K. L., Guha, K., Chanda, S., Laskar, N. M., & Biswas, D. (2017) · IEEE International Conference on Electron Devices and Solid-State Circuits (EDSSC) · doi:10.1109/edssc.2017.8333234 · Cited by 12 · see citing works
Carbonization of 3D printed polymer structures for CMOS-compatible electrochemical sensors
Haque, M. A., Lavrik, N. V., Hedayatipour, A., Hensley, D. K., Briggs, D. P., & McFarlane, N. M. (2020) · Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and Phenomena · doi:10.1116/6.0000266 · Cited by 12 · see citing works
High Performance 128-Channel Acquisition System for Electrophysiological Signals
Mannatunga, K. S., Ali, S. H. M., Crespo, M. L., Cicuttin, A., & Samarawickrama, J. G. (2020) · IEEE Access · doi:10.1109/access.2020.3007082 · Cited by 11 · see citing works
A Low-Noise Chopper Amplifier with Offset and Low-Frequency Noise Compensation DC Servo Loop
Liu, Y., Zhou, Z., Zhou, Y., Li, W., & Wang, Z. (2020) · Electronics · doi:10.3390/electronics9111797 · Cited by 11 · see citing works
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11 · see citing works
“…and narrow bandwidths (200 Hz to 10 kHz) demand high-gain pre-amplification (typically of about 40 dB to 60 dB) and filtering prior to digitisation and processing [156], and are recorded in the presence of large common mode signals requiring high common-mode rejection ratio (CMRR) [157], [158].”
InfluentialUddin, M. J., Hossain, M. K., Qarony, W., Hossain, M. I., Mia, M. N. H., & Hossen, S. (2017) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2017.07.008 · Cited by 10 · see citing works
A Low-Power Low-Noise Instrumentation Amplifier for Wearable Applications
Viana, N. L. M., & Belfort, D. R. (2019) · International Symposium on Instrumentation Systems, Circuits and Transducers (INSCIT) · doi:10.1109/inscit.2019.8868504 · Cited by 9 · see citing works
Electroceuticals for neural regenerative nanomedicine
Tomaskovic‐Crook, E., Higginbottom, S. L., James, E. C., Rathbone, S. J. C., & Crook, J. M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-820223-4.00007-3 · Cited by 9 · see citing works
A chronic implantable EMG recording system with wireless power and data transfer
Wong, M. D. S., Ng, K. A., Nag, S., Jegadeesan, R., Leong, K.-W., Ong, L. J., Rusly, A., Alam, M., Gammad, G. G. L., Tsai, C.-W., et al. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325079 · Cited by 8 · see citing works
Self-citationSimon, N., Stieglitz, T., & Bucher, V. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202403149 · Cited by 7 · see citing works
A Programmable Multi-Biomarker Neural Sensor for Closed-Loop DBS
Parastarfeizabadi, M., Kouzani, A. Z., Beckinghausen, J., Lin, T., & Sillitoe, R. V. (2018) · IEEE Access · doi:10.1109/access.2018.2885336 · Cited by 7 · see citing works
Wireless closed-loop deep brain stimulation using microelectrode array probes
Jia, Q., Liu, Y., Lv, S., Wang, Y., Jiao, P., Xu, W., Xu, Z., Wang, M., & Cai, X. (2024) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.b2300400 · Cited by 6 · see citing works
Ultra-Low Power Application-Specific Integrated Circuits for Sensing
Kassanos, P., Ip, H., & Yang, G. (2018) · Springer eBooks · doi:10.1007/978-3-319-69748-2_5 · Cited by 6 · see citing works
Omidvar, A., & Shaterian, M. (2019) · Microelectronics Journal · doi:10.1016/j.mejo.2019.104654 · Cited by 5 · see citing works
TinyLFP: A Tiny Local-Field-Potential Sensor
Kumari, L. S., & Kouzani, A. Z. (2022) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2022.3145650 · Cited by 5 · see citing works
A Glimpse of the History of Analog ICs: A Tale of Amplifiers, Data Converters, and Sensor Interfaces
Chae, Y., López, C. M., Makinwa, K. A. A., Ortmanns, M., & Sansen, W. (2023) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2023.3282557 · Cited by 5 · see citing works
Donoghue, J. P. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00025-5 · Cited by 5 · see citing works
CMOS Circuits in the Design and Development of Implantable Medical Devices
Laskar, M. J., Banerjee, A., Prasad, V., & Das, D. (2025) · Biomedical Materials & Devices · doi:10.1007/s44174-024-00267-0 · Cited by 4 · see citing works
A 0.6V 1.07 μW/Channel neural interface IC using level-shifted feedback
Lyu, L., Wang, Y., Chen, C., & Shi, C. ‐. R. (2019) · Integration · doi:10.1016/j.vlsi.2019.11.001 · Cited by 4 · see citing works
OTA-C Filters for Biomedical Signal Processing Applications using Hybrid CMOS-CNFET Technology
Rahane, S. B., Kureshi, A. K., & Kharate, G. K. (2018) · International Conference on Intelligent and Innovative Computing Applications · doi:10.1109/iconic.2018.8601085 · Cited by 3 · see citing works
High PSRR Folded Cascode OTA for Neural Signal Applications
Lopez-Solis, M., Woo-García, R. M., Argüelles-Lucho, P., Martínez-Castillo, J., Herrera‐May, A. L., Calleja-Arriaga, W., & López-Huerta, F. (2021) · doi:10.1109/iccs52645.2021.9697157 · Cited by 3 · see citing works
A Review on Neural Amplifier Design for Brain–Machine Interface
Nath, S., Guha, K., & Baishnab, K. L. (2023) · Lecture notes in electrical engineering · doi:10.1007/978-981-99-4495-8_28 · Cited by 3 · see citing works
Neural Recording Front-End Design
Liu, X., & der Spiegel, J. V. (2017) · Springer eBooks · doi:10.1007/978-3-319-67940-2_2 · Cited by 3 · see citing works
Probability model of sensitive similarity measures in information retrieval
Gu, X., & Zhang, J. (2020) · International Journal of Advanced Robotic Systems · doi:10.1177/1729881420901425 · Cited by 3 · see citing works
Bidirectional peripheral nerve interface and applications
Thakor, N. V., Wang, Q., & Greenwald, E. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592175 · Cited by 3 · see citing works
Self-citationMicroelectrodes array technology: A review of integrated circuit biopotential amplifiers
Pancotto, C., Swart, J. W., & Catunda, S. Y. C. (2016) · International Symposium on Instrumentation Systems, Circuits and Transducers (INSCIT) · doi:10.1109/inscit.2016.7598218 · Cited by 3 · see citing works
Trzpil-Jurgielewicz, B., Dąbrowski, W., & Hottowy, P. (2021) · Sensors · doi:10.3390/s21093116 · Cited by 2 · see citing works
An Integrated Signal Acquisition AFE for Latency Quantification of ENG Signals
Zhang, Y., Chakravarti, A., Tasellari, M., & Güler, Ü. (2019) · IEEE MIT Undergraduate Research Technology Conference (URTC) · doi:10.1109/urtc49097.2019.9660428 · Cited by 2 · see citing works
Nath, S., Kumar, N., Guha, K., Baishnab, K. L., & Rao, K. S. (2024) · Microsystem Technologies · doi:10.1007/s00542-023-05588-6 · Cited by 2 · see citing works
Robust Online Estimation of Biophysical Neural Circuits
Schmetterling, R., Burghi, T. B., & Sepulchre, R. J. (2023) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc49753.2023.10383582 · Cited by 2 · see citing works
The possibilities for the restoration of the laryngeal function: the current state-of-the-art
Reshetov, I. V., Polunin, G. V., Ananichuk, A. V., Ippolitov, L. I., & Коваленко, А. А. (2017) · Russian Bulletin of Otorhinolaryngology · doi:10.17116/otorino201782618-23 · Cited by 2 · see citing works
A 0.0046 mm2 low-distortion CMOS neural preamplifier for large-scale neuroelectronic interfaces
Trzpil-Jurgielewicz, B., Dąbrowski, W., & Hottowy, P. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716992 · Cited by 1 · see citing works
Wang, G., You, C., Feng, C., Yao, W., Zhao, Z., Xue, N., & Yao, L. (2024) · Biosensors · doi:10.3390/bios14070343 · Cited by 1 · see citing works
Realization of a resistor-less CMOS super capacitor-multiplier using modified-current conveyors
Mohamed, A. R., & Al-Absi, M. A. (2025) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2025.101044 · Cited by 1 · see citing works
Chen, Q., Huang, N., Tong, C., Liu, P., Que, S., Xue, H., Xiao, X., & Song, E. (2026) · npj Biosensing · doi:10.1038/s44328-026-00109-7 · Cited by 2 · see citing works
Advances in High-Resolution, Miniaturized Bioelectrical Neural Interface Design
Nguyen, A. T., Xu, J., Wu, T., Luu, D. K., & Yang, Z. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_23 · Cited by 1 · see citing works
A 1.2V 1.3µW Cascode Current Reuse Based Neural Amplifier with 113 dB Open-Loop Gain
Korada, S., & Bhat, M. S. (2023) · IEEE International Conference on Distributed Computing, VLSI, Electrical Circuits and Robotics (DISCOVER) · doi:10.1109/discover58830.2023.10316735 · Cited by 1 · see citing works
Design of a Low Noise Low Power Amplifier for Biomedical Applications
Pakdel, R., & Baghtash, H. F. (2018) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme.2018.8703557 · Cited by 1 · see citing works
Low-Power Biopotential Signal Acquisition System for Biomedical Applications
Tasneem, N. T. (2022) · doi:10.12794/metadc1944354 · Cited by 1 · see citing works
Behavioral Neuroscience: Who’s Afraid of the C57BL/6 Mouse?
Wallace, D. J., & Kerr, J. N. D. (2016) · Current Biology · doi:10.1016/j.cub.2016.09.047
Kasemsap, K. (2018) · Advances in web technologies and engineering book series · doi:10.4018/978-1-5225-3004-6.ch019
Parastarfeizabadi, M., & Kouzani, A. Z. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438727
An Analog Front-End for Non-Invasive Cutaneous Neural Signal Acquisition and Latency Quantification
Chakravarti, A., Zhang, Y., Tasellari, M., Ghovanloo, M., & Güler, Ü. (2020) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas48704.2020.9184676
A Real-Time On-Demand Deep Brain Stimulation Device Design and Validation
Deng, B., Li, X., Chang, S., Li, H., Liu, C., Wang, J., & Wei, X. (2020) · Chinese Control Conference (CCC) · doi:10.23919/ccc50068.2020.9189228
Review of Ultra-Low-Power CMOS Amplifier for Bio-electronic Sensor Interface
Srivastava, G., Dixit, A., Kumar, A., & Shukla, S. (2020) · Advances in intelligent systems and computing · doi:10.1007/978-981-15-5345-5_24
A Low-Power Ultra-Compact ultrasonic Communication System for Neural Spike Events Recording
Ma, Q., Feng, Y., & Ma, K. (2021) · IEEE International Ultrasonics Symposium · doi:10.1109/ius52206.2021.9593446
Advances in High-Resolution, Miniaturized Bioelectrical Neural Interface Design
Nguyen, A. T., Xu, J., Wu, T., Luu, D. K., & Yang, Z. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_23-2
An Ultra-Low Power Implantable Medical Devices: An Engineering Perspective
Sathyabhama, B., & Shankari, B. S. (2021) · Journal of University of Shanghai for Science and Technology · doi:10.51201/jusst/21/11920
Noise Power Minimization in CMOS Brain-Chip Interfaces
Stevenazzi, L., Baschirotto, A., Zanotto, G., Vallicelli, E. A., & Matteis, M. D. (2022) · Bioengineering · doi:10.3390/bioengineering9020042
Osborn, L. E., Betthauser, J., & Thakor, N. V. (2019) · Wiley eBooks · doi:10.1002/047134608x.w1424.pub2
Self-citationMneimneh, M., Quadir, N. A., & Albasha, L. (2024) · IEEE Access · doi:10.1109/access.2024.3441840
Design of a noise efficient bio-amplifier using CCFVF OTA for neurological signal acquisition
Nath, S., Devi, S., Laskar, N. M., Guha, K., & Baishnab, K. L. (2025) · Microsystem Technologies · doi:10.1007/s00542-025-05932-y
Mo, F., Song, Y., Xiao, G., Xu, Z., Lv, S., Xu, W., Liu, Y., Liu, J., Wang, M., Wu, Y., et al. (2026) · Fundamental Research · doi:10.1016/j.fmre.2026.01.004
Design of Low Noise Amplifier using NMOS CVF OTA for Neural Recording Applications
Singh, N., Laskar, N. M., Kumar, G., Dhanaji, T. H., & Singh, A. K. (2026) · International Conference on Next Generation Electronics (NELEX) · doi:10.1109/nelex69209.2026.11590824
Design and Analysis of Low-Power, Low-Noise OTA for Biomedical Application
Nath, S., Devi, S., Laskar, N. M., Guha, K., & Baishnab, K. L. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-92-0217-1_63
- Authors
- Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V.
- Affiliations
- National University of Singapore (SG)
- Johns Hopkins University (US)
- Corresponding author
- Ng, Kian Ann
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2016-01
- Volume
- 54
- Issue
- 1
- Pages
- 45-62
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- PMC
- PMC4958006
- OpenAlex
- W2297777790
- Cited by
- 83
- References
- 155
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 6 · 2023: 6 · 2022: 5 · 2021: 10 · 2020: 10 · 2019: 12 · 2018: 11 · 2017: 8 · 2016: 8
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Research Foundation-Prime Minister's office, Republic of Singapore (NRFCRP10201201)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › Undergraduate Neuroscience Education and Research
- Keywords
- neural amplifier, neural recording, neural prosthesis, brain-computer interface, deep brain stimulation, epilepsy treatment, low-power amplifier design, cortical recording
- MeSH terms
- Animals, Brain, Man-Machine Systems, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read under definition version 3 (extract-v3) on 2026-09-28.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-09-28.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review