Towards automatic detection of falls using wireless sensors
The DOI matches its Crossref record.
Abstract
Accurate detection of falls leading to injury is essential for providing timely medical assistance. In this paper, we describe a wireless sensor network system for automatic fall detection. To detect falls, we use a combination of a body-worn triaxial accelerometer with motion detectors placed in the monitored area. While accelerometer provides information about the body motion during a fall, motion detectors monitor general presence or absence of motion. From all sensors, the data is transmitted wirelessly using the IEEE 802.15.4 protocol to a central node for processing. We use an implementation of Carrier Sense Multiple Access-Collision Avoidance scheme for channel reuse. A simple forwarding scheme is used to provide an extended coverage for a home environment. Fall detection is accomplished by a two-stage algorithm that utilizes the triaxial acceleration and the motion data sequentially. In the first stage, the algorithm detects plausible falls using a measure of normalized energy expenditure computed from the dynamic acceleration values. In the second stage, falls are confirmed based on the absence of motion. Systematic evaluation on simulated falls using 15 adult subjects shows that the proposed system provides a highly promising solution for real-time fall detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey on fall detection: Principles and approaches
Mubashir, M., Shao, L., & Seed, L. (2013) · Neurocomputing · doi:10.1016/j.neucom.2011.09.037 · Cited by 869
Automatic Fall Monitoring: A Review
Pannurat, N., Thiemjarus, S., & Nantajeewarawat, E. (2014) · Sensors · doi:10.3390/s140712900 · Cited by 237
“Other ADLs used in few studies and are not listed in Table 2 include ice skating [52], answering phone [53], waving phone [55], having chest pain [62], climbing into bed [46], hand shaking [79], having headache [62], hopping [38], jumping into bed [50], rotating in chair [38], sitting on or getting up from different t…”
BackgroundInfluentialFall Detection Devices and Their Use With Older Adults: A Systematic Review
Chaudhuri, S., Thompson, H., & Demiris, G. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe779 · Cited by 215
Peetoom, K. K. B., Lexis, M. A. S., Joore, M., Dirksen, C. D., & De Witte, L. P. (2015) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2014.961179 · Cited by 208
Ambient Sensors for Elderly Care and Independent Living: A Survey
Uddin, M. Z., Khaksar, W., & Torresen, J. (2018) · Sensors · doi:10.3390/s18072027 · Cited by 166
“[143] (2007) Fall detection The system applied triaxial accelerometer and motion detector sensor data in a two-step fall detection algorithm.”
MethodFall detection with body-worn sensors: A systematic review
for the FARSEEING Consortium and the FARSEEING Meta Database Consensus Group, Schwickert, L., Becker, C., Lindemann, U., Maréchal, C., Bourke, A., Chiari, L., Helbostad, J. L., Zijlstra, W., Aminian, K., et al. (2013) · Zeitschrift für Gerontologie und Geriatrie · doi:10.1007/s00391-013-0559-8 · Cited by 148
Metadata
- Authors
- Srinivasan, S., Han, J., Lal, D., & Gacic, A.
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 1379-1382
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2163361818
- Cited by
- 37
- References
- 0
- FWCI
- 1.37
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.