The DOI matches its Crossref record.
Automatic sleep stage classification based on EEG signals by using neural networks and wavelet packet coefficients
Abstract
Currently in the world there is an alarming number of people who suffer from sleep disorders. A number of biomedical signals, such as EEG, EMG, ECG and EOG are used in sleep labs among others for diagnosis and treatment of sleep related disorders. The usual method for sleep stage classification is visual inspection by a sleep specialist. This is a very time consuming and laborious exercise. Automatic sleep stage classification can facilitate this process. The definition of sleep stages and the sleep literature show that EEG signals are similar in Stage 1 of non-rapid eye movement (NREM) sleep and rapid eye movement (REM) sleep. Therefore, in this work an attempt was made to classify four sleep stages consisting of Awake, Stage 1 + REM, Stage 2 and Slow Wave Stage based on the EEG signal alone. Wavelet packet coefficients and artificial neural networks were deployed for this purpose. Seven all night recordings from Physionet database were used in the study. The results demonstrated that these four sleep stages could be automatically discriminated from each other with a specificity of 94.4 +/- 4.5%, a of sensitivity 84.2+3.9% and an accuracy of 93.0 +/- 4.0%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sleep Stage Classification Using EEG Signal Analysis: A Comprehensive Survey and New Investigation
Aboalayon, K., Faezipour, M., Almuhammadi, W., & Moslehpour, S. (2016) · Entropy · doi:10.3390/e18090272 · Cited by 382
Şen, B., Peker, M., Çavuşoğlu, A., & Çelebi, F. V. (2014) · Journal of Medical Systems · doi:10.1007/s10916-014-0018-0 · Cited by 282
Neural Decoding of EEG Signals with Machine Learning: A Systematic Review
Saeidi, M., Karwowski, W., Farahani, F. V., Fiok, K., Taiar, R., Hancock, P. A., & Al-Juaid, A. (2021) · Brain Sciences · doi:10.3390/brainsci11111525 · Cited by 258
DoppleSleep: a contactless unobtrusive sleep sensing system using short-range Doppler radar
Rahman, T., Adams, A. T., Ravichandran, R. V., Zhang, M., Patel, S. N., Kientz, J. A., & Choudhury, T. (2015) · Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2750858.2804280 · Cited by 175
Automating sleep stage classification using wireless, wearable sensors
Boe, A. J., McGee Koch, L. L., O’Brien, M. K., Shawen, N., Rogers, J. A., Lieber, R. L., Reid, K. J., Zee, P. C., & Jayaraman, A. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0210-1 · Cited by 98
Metadata
- Authors
- Ebrahimi, F., Mikaeili, M., Estrada, E., & Nazeran, H.
- Venue
- 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2008-08
- Volume
- 2008
- Pages
- 1151-1154
- OpenAlex
- W2148616726
- Cited by
- 208
- References
- 0
- FWCI
- 6.46
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic sleep stage classification based on EEG signals by using neural networks and wavelet packet coefficients. https://app.cochat.ai/papers/10.1109/iembs.2008.4649365
- The paper
- Ebrahimi, F., Mikaeili, M., Estrada, E., & Nazeran, H. (2008). Automatic sleep stage classification based on EEG signals by using neural networks and wavelet packet coefficients. 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2008.4649365
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.