Cuffless blood pressure estimation by error-correcting output coding method based on an aggregation of AdaBoost with a photoplethysmograph sensor
Abstract
This paper presented a novel cuffless and non-invasive technique of Blood Pressure (BP) estimation with a pattern recognition method by using a Photoplethysmograph (PPG) sensor instead of a cuff. Error-Correcting Output Coding (ECOC) method was adopted as a multi-classifier machine based on an aggregation of general binary classifiers. AdaBoost was applied as binary classifier machine. 368 volunteers participated in the experiment. The estimated Systolic Blood Pressure (SBP) was calculated from their individual information and several features of their Pulse Wave (PW). As a result of the comparison between measured SBP, estimated SBP, MD = -1.2 [mmHg] and SD = 11.7 [mmHg] were obtained. Hence, this technique would be helpful to the advance the development of continuous BP monitoring system, since the only one device to monitor BP is smaller than traditional measurements.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Artificial intelligence and machine learning have been used to determine blood pressure from PPG and mitigate the effects age have on the estimate.
“Artificial intelligence and machine learning have been used to determine blood pressure from PPG and mitigate the effects age have on the estimate.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [96]
Suzuki and Oguri used artificial intelligence to determine blood pressure from a cuffless monitor and incorporated age into their algorithm.
“Suzuki and Oguri similarly used artificial intelligence to determine blood pressure from a cuffless monitor and incorporated age into their algorithm [96].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [96]
The citation lists haven’t been fetched yet
References 10 · Cited by 31
- Authors
- Suzuki, S., & Oguri, K.
- Affiliations
- Aichi Prefectural University (JP)
- Venue
- 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2009-09
- Volume
- 2009
- Pages
- 6765-6768
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2108213815
- Cited by
- 31
- References
- 10
- Citations by year
- 2026: 1 · 2025: 3 · 2023: 3 · 2022: 7 · 2021: 5 · 2020: 2 · 2017: 1 · 2016: 2 · 2014: 1 · 2013: 3
- FWCI
- 2.08
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- cuffless blood pressure measurement, non-invasive blood pressure monitoring, photoplethysmography, error-correcting output coding, AdaBoost, classifier aggregation, systolic blood pressure, continuous blood pressure monitoring
- MeSH terms
- Adult, Aged, Algorithms, Blood Pressure, Blood Pressure Determination, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Pulse, Systole, Photoplethysmography, Age Distribution, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review