Recent advances in charge balancing for functional electrical stimulation
Abstract
Charge balancing is a major concern in functional electrical stimulation, since any excess charge accumulation over time leads to electrolysis with electrode dissolution and tissue destruction. Its major function is to ensure that the mean value of electrode voltage is kept within a safe level. However, it serves as a failure protection as well. This paper presents an overview on recent advances in this field, both passive and active (closed-loop) charge balancing techniques.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A series blocking capacitor can prevent the flow of dc currents, determine the maximum charge per phase, and provide an equal charge by discharging in a reverse pulse.
“A series blocking capacitor can prevent the flow of dc currents, determine the maximum charge per phase, and provide an equal charge by discharging in a reverse pulse. The large capacitance required is unsuitable for miniaturisation and may introduce additional offsets due to secondary effects [143].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [143]
The citation lists haven’t been fetched yet
References 16 · Cited by 20
- Authors
- Sooksood, K., Stieglitz, T., & Ortmanns, M.
- Affiliations
- Universität Ulm (DE)
- University of Freiburg (DE)
- Venue
- 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2009-09
- Volume
- 2009
- Pages
- 5518-5521
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2121773578
- Cited by
- 20
- References
- 16
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 2 · 2021: 1 · 2019: 2 · 2018: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 2 · 2012: 1
- FWCI
- 5.37
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- charge balancing, functional electrical stimulation, electrolysis, electrode dissolution, electrode voltage, feedback control, failure protection, tissue damage
- MeSH terms
- Electronics, Medical, Electric Stimulation Therapy, Equipment Design, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Reproducibility of Results, Equipment Failure Analysis, Static Electricity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›