Effect of anatomical variability on neural stimulation strength and focality in electroconvulsive therapy (ECT) and magnetic seizure therapy (MST)
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We present a quantitative comparison of two metrics-neural stimulation strength and focality-in electrocon-vulsive therapy (ECT) and magnetic seizure therapy (MST) using finite-element method (FEM) simulation in a spherical head model. Five stimulation modalities were modeled, including bilateral ECT, unilateral ECT, focal electrically administered seizure therapy (FEAST), and MST with circular and double-cone coils, with stimulation parameters identical to those applied in clinical practice. We further examine the effect on the stimulation metrics of individual-, sex- and age-related variability in tissue layer thickness and conductivity. Neural stimulation by MST is shown to be more focal and superficial than ECT. This result suggests that it may be advantageous to reduce the current used in ECT. The stimulation strength in MST is also less sensitive to variations in head geometry and tissue conductivity than in ECT. Individualization of pulse amplitude in both ECT and MST could compensate for anatomical variability, which could lead to more consistent clinical outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electroconvulsive Therapy for Depression
Lisanby, S. H. (2007) · New England Journal of Medicine · doi:10.1056/nejmct075234 · Cited by 503 · cited 2×
“For ECT-RUL, one electrode was in the right frontotemporal position; the second electrode was placed to the right of vertex [ 1 ].”
BackgroundMethodSelf-citationAxons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492 · cited 1×
“It is thought that the axon is the neural element preferentially depolarized by extracellular electric field stimulation, therefore it can be assumed that ���� ���� = 150 µs [24],[ 25 ].”
BackgroundAcute Efficacy of ECT in the Treatment of Major Depression in the Old-Old
Tew, J. D., Mulsant, B. H., Haskett, R. F., Prudic, J., Thase, M. E., Crowe, R. R., Dolata, D., Begley, A. E., Reynolds, C. F., & Sackeim, H. A. (1999) · American Journal of Psychiatry · doi:10.1176/ajp.156.12.1865 · Cited by 231
Cited by
Rossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
Self-citationDeng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.02.005 · Cited by 1,073
Self-citationPeterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual-Leone, A., & Bikson, M. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 429
Self-citationDeng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016007 · Cited by 216
Self-citationElectroconvulsive Therapy Stimulus Parameters: Rethinking Dosage
Peterchev, A. V., Rosa, M. A., Deng, Z.-D., Prudic, J., & Lisanby, S. H. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48165 · Cited by 213
“Thus, at present, there are limited data on the effects of stimulus polarity; this parameter should be explored further within studies of unidirectional ECT.”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V.
- Venue
- 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2009-09
- Volume
- 2009
- Pages
- 682-688
- OpenAlex
- W2120838083
- Cited by
- 45
- References
- 3
- FWCI
- 44.33
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.