Evaluation of PERCLOS based current fatigue monitoring technologies
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In an overnight driving simulation study three commercially available devices of fatigue monitoring technologies (FMT) were applied to test their accuracy. 16 volunteers performed driving tasks during eight sessions (40 min each) separated by 15 minutes breaks. The main output variable of FMT devices, which is the percentage of eye closure (PERCLOS), the driving performance (standard deviation of lateral position in lane, SDL), the electroencephalogram (EEG) and electrooculogram (EOG) were recorded during driving. In addition, the subjective self-rated Karolinska sleepiness scale (KSS) was assessed every 2 min. As expected, Pearson product-moment correlation coefficient (PMCC) yielded significant linear dependence between KSS and PERCLOS as well as between SDL and PERCLOS. However, if PMCC was estimated within smaller data segments (3 min) as well as without averaging across subjects then strongly decreased correlation coefficients resulted. To further validate PERCLOS at higher temporal resolution its ability to discriminate between mild and strong fatigue was investigated and compared to the results of the same analysis for EEG/EOG. Spectral-domain features of both types of signals were classified using Support-Vector Machines (SVM). Results suggest that EEG/EOG indicate driver fatigue much better than PERCLOS. Therefore, current FMT devices perform acceptably if temporal resolution is low (> 20 min). But, even under laboratory conditions large errors have to be expected if fatigue is estimated on an individual level and with high temporal resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subjective and objective sleepiness in the active individual
Åkerstedt, T., & Gillberg, M. (1990) · International Journal of Neuroscience · doi:10.3109/00207459008994241 · Cited by 3,088 · cited 1×
“The self-report of sleepiness on the Karolinska sleepiness scale (KSS) [ 2 ] acted as a subjective fatigue measure, and the driving performance in terms of standard deviations of lateral position in lane (SDL) [3] acted as an objective fatigue measure.”
Method
Cited by
A sensor fusion approach for drowsiness detection in wearable ultra-low-power systems
Kartsch, V. J., Benatti, S., Schiavone, P. D., Rossi, D., & Benini, L. (2018) · Information Fusion · doi:10.1016/j.inffus.2017.11.005 · Cited by 69
Adapting shift work schedules for sleep quality, sleep duration, and sleepiness in shift workers
Hulsegge, G., Coenen, P., Gascon, G. M., Pahwa, M., Greiner, B., Bohane, C., Wong, I. S., Liira, J., Riera, R., & Pachito, D. V. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010639.pub2 · Cited by 31
Erren, T. C., Herbst, C., Koch, M. S., Fritschi, L., Foster, R. G., Driscoll, T. R., Costa, G., Sallinen, M., & Liira, J. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010639 · Cited by 9
Metadata
- Authors
- Sommer, D., & Golz, M.
- Venue
- 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2010-08
- Volume
- 2010
- Pages
- 4456-4459
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W1979069952
- Cited by
- 104
- References
- 1
- FWCI
- 6.70
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of PERCLOS based current fatigue monitoring technologies. https://app.cochat.ai/papers/10.1109/iembs.2010.5625960
- The paper
- Sommer, D., & Golz, M. (2010). Evaluation of PERCLOS based current fatigue monitoring technologies. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5625960
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.