On-line classification of human activity and estimation of walk-run speed from acceleration data using support vector machines
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The awareness of the physical activity that human subjects perform, and the quantification of activity strength and duration are important tasks that a wearable sensor system would fulfill to be valuable in several biomedical applications, from health monitoring to physical medicine and rehabilitation. In this work we develop a wearable sensor system that collect data from a single thigh-mounted tri-axial accelerometer; the system performs activity classification (sit, stand, cycle, walk, run), and speed estimation for walk (run) labeled data features. These classification/estimation tasks are achieved by cascading two Support Vector Machines (SVM) classifiers. Activity classification accuracy higher than 99% and root mean square errors E(RMS) = 0.28 km/h for speed estimation are obtained in our preliminary experiments. The developed wearable sensor system provides activity labels and speed point estimates at the pace of two readings per second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551 · cited 1×
“methods for automatically classifying human physical activities [3,4].”
Method
Cited by
A Survey on Activity Detection and Classification Using Wearable Sensors
Cornacchia, M., Ozcan, K., Zheng, Y., & Velipasalar, S. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2628346 · Cited by 424
Feature Selection and Activity Recognition System Using a Single Triaxial Accelerometer
Gupta, P., & Dallas, T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2307069 · Cited by 335
Application of data fusion techniques and technologies for wearable health monitoring
King, R. C., Villeneuve, E., White, R. J., Sherratt, R. S., Holderbaum, W., & Harwin, W. S. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.12.011 · Cited by 182
“• Support Vector Machines (SVM) - SVM have been extensively used for human activity classification [16,17,36,39,42,43] and can be used for both linear and non-linear classification problems.”
MethodPerformance of activity classification algorithms in free-living older adults
SASAKI, J. E., HICKEY, A. M., STAUDENMAYER, J. W., JOHN, D., KENT, J. A., & FREEDSON, P. S. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000844 · Cited by 112
“A description of these machine learning techniques can be found elsewhere (10,12).”
Background
Metadata
- Authors
- Mannini, A., & Sabatini, A. M.
- Venue
- 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2011-08
- Volume
- 2011
- Pages
- 3302-3305
- OpenAlex
- W1977277483
- Cited by
- 37
- References
- 1
- FWCI
- 1.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On-line classification of human activity and estimation of walk-run speed from acceleration data using support vector machines. https://app.cochat.ai/papers/10.1109/iembs.2011.6090896
- The paper
- Mannini, A., & Sabatini, A. M. (2011). On-line classification of human activity and estimation of walk-run speed from acceleration data using support vector machines. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6090896
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.