A multi-modal approach for hand motion classification using surface EMG and accelerometers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
For decades, electromyography (EMG) has been used for diagnostics, upper-limb prosthesis control, and recently even for more general human-machine interfaces. Current commercial upper limb prostheses usually have only two electrode sites due to cost and space limitations, while researchers often experiment with multiple sites. Micro-machined inertial sensors are gaining popularity in many commercial and research applications where knowledge of the postures and movements of the body is desired. In the present study, we have investigated whether accelerometers, which are relatively cheap, small, robust to noise, and easily integrated in a prosthetic socket; can reduce the need for adding more electrode sites to the prosthesis control system. This was done by adding accelerometers to a multifunction system and also to a simplified system more similar to current commercially available prosthesis controllers, and assessing the resulting changes in classification accuracy. The accelerometer does not provide information on muscle force like EMG electrodes, but the results show that it provides useful supplementary information. Specifically, if one wants to improve a two-site EMG system, one should add an accelerometer affixed to the forearm rather than a third electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Self-citation
Cited by
Lu, Z., Chen, X., Li, Q., Zhang, X., & Zhou, P. (2014) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2014.2302794 · Cited by 294
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Ortiz-Catalan, M., Brånemark, R., & Håkansson, B. (2013) · Source Code for Biology and Medicine · doi:10.1186/1751-0473-8-11 · Cited by 232
Ahmadizadeh, C., Merhi, L.-K., Pousett, B., Sangha, S., & Menon, C. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2747899 · Cited by 57
“The currently available sensory system for controlling robotic hands is based on sEMG [8], which has specific downsides: sEMG’s signals are affected by interference from ambient noise, electrode shifts, sweat and humidity, and signal crosstalk between adjacent electrodes [9].”
Background
Metadata
- Authors
- Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K., & Stavdahl, O.
- Venue
- 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2011-08
- Volume
- 2011
- Pages
- 4247-4250
- OpenAlex
- W2009107851
- Cited by
- 63
- References
- 1
- FWCI
- 9.49
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.