Cited by 232Muscle activation and electromyography studiesProsthetics and Rehabilitation RoboticsNeuroscience and Neural Engineering

BioPatRec: A modular research platform for the control of artificial limbs based on pattern recognition algorithms

Open access
Ortiz-Catalan, Max, Brånemark, Rickard, Håkansson, Bo·2013·Source Code for Biology and Medicine

Abstract

BACKGROUND: Processing and pattern recognition of myoelectric signals have been at the core of prosthetic control research in the last decade. Although most studies agree on reporting the accuracy of predicting predefined movements, there is a significant amount of study-dependent variables that make high-resolution inter-study comparison practically impossible. As an effort to provide a common research platform for the development and evaluation of algorithms in prosthetic control, we introduce BioPatRec as open source software. BioPatRec allows a seamless implementation of a variety of algorithms in the fields of (1) Signal processing; (2) Feature selection and extraction; (3) Pattern recognition; and, (4) Real-time control. Furthermore, since the platform is highly modular and customizable, researchers from different fields can seamlessly benchmark their algorithms by applying them in prosthetic control, without necessarily knowing how to obtain and process bioelectric signals, or how to produce and evaluate physically meaningful outputs. RESULTS: BioPatRec is demonstrated in this study by the implementation of a relatively new pattern recognition algorithm, namely Regulatory Feedback Networks (RFN). RFN produced comparable results to those of more sophisticated classifiers such as Linear Discriminant Analysis and Multi-Layer Perceptron. BioPatRec is released with these 3 fundamentally different classifiers, as well as all the necessary routines for the myoelectric control of a virtual hand; from data acquisition to real-time evaluations. All the required instructions for use and development are provided in the online project hosting platform, which includes issue tracking and an extensive "wiki". This transparent implementation aims to facilitate collaboration and speed up utilization. Moreover, BioPatRec provides a publicly available repository of myoelectric signals that allow algorithms benchmarking on common data sets. This is particularly useful for researchers lacking of data acquisition hardware, or with limited access to patients. CONCLUSIONS: BioPatRec has been made openly and freely available with the hope to accelerate, through the community contributions, the development of better algorithms that can potentially improve the patient's quality of life. It is currently used in 3 different continents and by researchers of different disciplines, thus proving to be a useful tool for development and collaboration.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1751-0473-8-11

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ortiz-Catalan, M., Brånemark, R., & Håkansson, B.
Affiliations
  • Chalmers University of Technology (SE)
  • Sahlgrenska University Hospital (SE)
Corresponding author
Ortiz-Catalan, Max
Venue
Source Code for Biology and Medicine
Published
2013-04-18
Volume
8
Issue
1
Pages
11-11
ISSN
1751-0473 (ISSN-L)
OpenAlex
W2152093652
Cited by
232
References
3
Citations by year
2026: 27 · 2025: 21 · 2024: 21 · 2023: 18 · 2022: 15 · 2021: 15 · 2020: 19 · 2019: 15 · 2018: 25 · 2017: 21 · 2016: 12 · 2015: 10 · 2014: 8 · 2013: 5
FWCI
6.44
Type
journal article
Language
en
Open access
Locations
  • Source Code for Biology and Medicine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Gothenburg University Publications Electronic Archive (Gothenburg University) (acceptedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
  • Chalmers Research (Chalmers University of Technology) (submittedVersion)
Funders
  • VINNOVA (2010-00482)
  • Chalmers Tekniska Högskola
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
myoelectric signal processing, prosthetic control, pattern recognition, open source software, feature extraction, real-time control, virtual hand, benchmarking, open science platforms

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review