Clinical assessment scales to evaluate motor abilities in stroke survivors could be used to individualize rehabilitation interventions thus maximizing motor gains. Unfortunately, these scales are not widely utilized in clinical practice because their administration is excessively time-consuming. Wearable sensors could be relied upon to address this issue. Sensor data could be unobtrusively gathered during the performance of motor tasks. Features extracted from the sensor data could provide the input to models designed to estimate the severity of motor impairments and functional limitations. In previous work, we showed that wearable sensor data collected during the performance of items of the Wolf Motor Function Test (a clinical scale designed to assess functional capability) can be used to estimate scores derived using the Functional Ability Scale, a clinical scale focused on quality of movement. The purpose of the study herein presented was to investigate whether the same dataset could be used to estimate clinical scores derived using the Fugl-Meyer Assessment scale (a clinical scale designed to assess motor impairments). Our results showed that Fugl-Meyer Assessment Test scores can be estimated by feeding a Random Forest with features derived from wearable sensor data recorded during the performance of as few as a single item of the Wolf Motor Function Test. Estimates achieved using the proposed method were marked by a root mean squared error as low as 4.7 points of the Fugl-Meyer Assessment Test scale.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Data Mining: Practical Machine Learning Tools and Techniques
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-19715-5 · Cited by 25,437
Heart Disease and Stroke Statistics—2010 Update: A Report From the American Heart Association
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R. J., Brown, T. M., Carnethon, M., Dai, S., De Simone, G., Ferguson, T. B., Ford, E., Furie, K., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192667 · Cited by 5,700
Assessing Wolf Motor Function Test as Outcome Measure for Research in Patients After Stroke
Wolf, S. L., Catlin, P. A., Ellis, M., Archer, A. L., Morgan, B., & Piacentino, A. (2001) · Stroke · doi:10.1161/01.str.32.7.1635 · Cited by 1,051
Reliability of the Fugl-Meyer Assessment for Testing Motor Performance in Patients Following Stroke
Sanford, J., Moreland, J., Swanson, L. R., Stratford, P. W., & Gowland, C. (1993) · Physical Therapy · doi:10.1093/ptj/73.7.447 · Cited by 732
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Self-citationH. van der Lee, H. B. (2001) · Journal of Rehabilitation Medicine · doi:10.1080/165019701750165916 · Cited by 383
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382 · cited 1×
“Wearable sensors could be used to address this problem [4, 5, 6].”
MethodSelf-citationA Novel Approach to Monitor Rehabilitation Outcomes in Stroke Survivors Using Wearable Technology
Patel, S., Hughes, R., Hester, T., Stein, J., Akay, M., Dy, J. G., & Bonato, P. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038727 · Cited by 170 · cited 3×
“if the methodology we previously developed to estimate FAS scores [8] could be extended to the estimation of FMA”
BackgroundMethodSelf-citationUsing Wearable Sensors to Measure Motor Abilities following Stroke
Hester, T., Hughes, R., Sherrill, D. M., Knorr, B., Akay, M., Stein, J., & Bonato, P. (2006) · International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06) · doi:10.1109/bsn.2006.57 · Cited by 82 · cited 1×
“Previous studies by our team showed that wearable sensor data can be used to estimate clinical scores of movement ability [7, 8].”
BackgroundSelf-citation
Research works printed but not linked: 2
- 2004, Stroke Hope Through Research
- 2010, Heart Disease and Stroke Statistics - 2010 Update
Cited by
Maceira-Elvira, P., Popa, T., Schmid, A.-C., & Hummel, F. C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0612-y · Cited by 265
Computational neurorehabilitation: modeling plasticity and learning to predict recovery
Reinkensmeyer, D. J., Burdet, E., Casadio, M., Krakauer, J. W., Kwakkel, G., Lang, C. E., Swinnen, S. P., Ward, N. S., & Schweighofer, N. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0148-3 · Cited by 183
Plan, Activity, and Intent Recognition
Sukthankar, G., Geib, C., Bui, H., Pynadath, D. V., & Goldman, R. P. (2014) · Elsevier eBooks · doi:10.1016/c2012-0-01169-6 · Cited by 181
A review of computational approaches for evaluation of rehabilitation exercises
Liao, Y., Vakanski, A., Xian, M., Paul, D. R., & Baker, R. T. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103687 · Cited by 172
Yu, L., Xiong, D., Guo, L., & Wang, J. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.02.012 · Cited by 134
Metadata
- Authors
- Del Din, S., Patel, S., Cobelli, C., & Bonato, P.
- Affiliations
- Harvard University (US)
- University of Padua (IT)
- Venue
- 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2011-08
- Volume
- 2011
- Pages
- 5839-5842
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2046013276
- Cited by
- 90
- References
- 13
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 8 · 2022: 13 · 2021: 12 · 2020: 10 · 2019: 5 · 2018: 10 · 2017: 4 · 2016: 7 · 2015: 7 · 2014: 4 · 2013: 3
- FWCI
- 2.90
- Type
- conference paper
- Language
- en
- Open access
- green
- doi.org
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Newcastle University ePrints (Newcastle Univesity)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R24HD065688, R24HD050821)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- Fugl-Meyer Assessment, stroke, wearable sensors, motor impairment assessment, Wolf Motor Function Test, random forest, stroke rehabilitation, functional capacity
- MeSH terms
- Acceleration, Diagnosis, Computer-Assisted, Equipment Design, Humans, Movement Disorders, Physical Examination, Sensitivity and Specificity, Severity of Illness Index, Transducers, Reproducibility of Results, Monitoring, Ambulatory, Equipment Failure Analysis, Recovery of Function, Stroke, Actigraphy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimating fugl-meyer clinical scores in stroke survivors using wearable sensors. https://app.cochat.ai/papers/10.1109/iembs.2011.6091444
- The paper
- Del Din, S., Patel, S., Cobelli, C., & Bonato, P. (2011). Estimating fugl-meyer clinical scores in stroke survivors using wearable sensors. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6091444
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.