CoChat

Estimating fugl-meyer clinical scores in stroke survivors using wearable sensors

Open access
Del Din, S., Patel, S., Cobelli, C., Bonato, P. · 2011 · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Clinical assessment scales to evaluate motor abilities in stroke survivors could be used to individualize rehabilitation interventions thus maximizing motor gains. Unfortunately, these scales are not widely utilized in clinical practice because their administration is excessively time-consuming. Wearable sensors could be relied upon to address this issue. Sensor data could be unobtrusively gathered during the performance of motor tasks. Features extracted from the sensor data could provide the input to models designed to estimate the severity of motor impairments and functional limitations. In previous work, we showed that wearable sensor data collected during the performance of items of the Wolf Motor Function Test (a clinical scale designed to assess functional capability) can be used to estimate scores derived using the Functional Ability Scale, a clinical scale focused on quality of movement. The purpose of the study herein presented was to investigate whether the same dataset could be used to estimate clinical scores derived using the Fugl-Meyer Assessment scale (a clinical scale designed to assess motor impairments). Our results showed that Fugl-Meyer Assessment Test scores can be estimated by feeding a Random Forest with features derived from wearable sensor data recorded during the performance of as few as a single item of the Wolf Motor Function Test. Estimates achieved using the proposed method were marked by a root mean squared error as low as 4.7 points of the Fugl-Meyer Assessment Test scale.

Overview

Integrity signals

Registry

Crossref · 10.1109/iembs.2011.6091444

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 13 references

Research works printed but not linked: 2

  1. 2004, Stroke Hope Through Research
  2. 2010, Heart Disease and Stroke Statistics - 2010 Update

Cited by

See all 99

Metadata

Authors
Del Din, S., Patel, S., Cobelli, C., & Bonato, P.
Affiliations
  • Harvard University (US)
  • University of Padua (IT)
Venue
2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2011-08
Volume
2011
Pages
5839-5842
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2046013276
Cited by
90
References
13
Citations by year
2026: 1 · 2025: 3 · 2024: 3 · 2023: 8 · 2022: 13 · 2021: 12 · 2020: 10 · 2019: 5 · 2018: 10 · 2017: 4 · 2016: 7 · 2015: 7 · 2014: 4 · 2013: 3
FWCI
2.90
Type
conference paper
Language
en
Open access
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
  • Padua Research Archive (University of Padova) (submittedVersion)
  • Newcastle University ePrints (Newcastle Univesity)
Funders
Eunice Kennedy Shriver National Institute of Child Health and Human Development (R24HD065688, R24HD050821)
Topics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
Keywords
Fugl-Meyer Assessment, stroke, wearable sensors, motor impairment assessment, Wolf Motor Function Test, random forest, stroke rehabilitation, functional capacity
MeSH terms
Acceleration, Diagnosis, Computer-Assisted, Equipment Design, Humans, Movement Disorders, Physical Examination, Sensitivity and Specificity, Severity of Illness Index, Transducers, Reproducibility of Results, Monitoring, Ambulatory, Equipment Failure Analysis, Recovery of Function, Stroke, Actigraphy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating fugl-meyer clinical scores in stroke survivors using wearable sensors. https://app.cochat.ai/papers/10.1109/iembs.2011.6091444
The paper
Del Din, S., Patel, S., Cobelli, C., & Bonato, P. (2011). Estimating fugl-meyer clinical scores in stroke survivors using wearable sensors. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6091444

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.