High Quality Sensor Placement for SHM Systems: Refocusing on Application Demands
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
There are heavy studies recently on applying wireless sensor networks for structural health monitoring. These works usually focus on the computer science aspect, and the considerations include energy consumption, network connectivity, etc. It is commonly believed that for the current resource limited wireless sensors, system design could be more efficient if the application requirements are incorporated. Nevertheless, we often find that, rather than integration, assumptions have to be made due to lack of knowledge of civil engineering; for example, to evaluate routing algorithms, the sensor placement is assumed to be random or on grids/trees. These may not be practically meaningful to the respective application demands, and make the great efforts by the computer science community on developing efficient methods from the sensor network aspect less useful. In this paper, we study the very first problem of the SHM systems: the sensor placement and focus on the civil requirements. We first study the current general framework of structure health monitoring. We redevelop the framework that includes a new sensor placement module. This module implements the most widely accepted sensor placement scheme from civil engineering but focusing on its usefulness for computer science. It provides such interfaces that can rank the placement quality of the candidate locations in a step by step manner. We then optimize system performance by considering network connectivity and data routing issues; with the objective on energy efficiency. We evaluate our scheme using the data from the structural health monitoring system on the Ting Kau Bridge, Hong Kong. We show that a uniform and a state-of-the-art placement are not very meaningful in placement quality. Our scheme achieves almost the same sensor placement quality with that of the civil engineering with five-fold improvement in system lifetime. We conduct an experiment on the in-built Guangzhou New TV Tower, China; and the results validate the effectiveness of our scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensor placement for on-orbit modal identification and correlation of large space structures
Kammer, D. C. (1991) · Journal of Guidance, Control, and Dynamics · doi:10.2514/3.20635 · Cited by 935
Cited by
Structural Health Monitoring Using Wireless Sensor Networks: A Comprehensive Survey
Noel, A. B., Abdaoui, A., Elfouly, T., Ahmed, M. H., Badawy, A., & Shehata, M. S. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2691551 · Cited by 489
Real-Time Wireless Sensor-Actuator Networks for Industrial Cyber-Physical Systems
Lu, C., Saifullah, A., Li, B., Sha, M., Gonzalez, H., Gunatilaka, D., Wu, C., Nie, L., & Chen, Y. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2497161 · Cited by 388
Self-citationThe Sensable City: A Survey on the Deployment and Management for Smart City Monitoring
Du, R., Santi, P., Xiao, M., Vasilakos, A. V., & Fischione, C. (2019) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2018.2881008 · Cited by 289
Dependable Structural Health Monitoring Using Wireless Sensor Networks
Bhuiyan, M. Z. A., Wang, G., Wu, J., Cao, J., Liu, X., & Wang, T. (2017) · IEEE Transactions on Dependable and Secure Computing · doi:10.1109/tdsc.2015.2469655 · Cited by 210
“[5], [6], [7], [8], [9], [10], [11], [19], [23], but they suffer from the dependability problem.”
BackgroundMethodInfluentialDeploying Wireless Sensor Networks with Fault-Tolerance for Structural Health Monitoring
Bhuiyan, M. Z. A., Wang, G., Cao, J., & Wu, J. (2015) · IEEE Transactions on Computers · doi:10.1109/tc.2013.195 · Cited by 189
Computational methodologies for optimal sensor placement in structural health monitoring: A review
Tan, Y., & Zhang, L. (2020) · Structural Health Monitoring · doi:10.1177/1475921719877579 · Cited by 186
Hassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23063293 · Cited by 146
Mustapha, S., Lu, Y., Ng, C.-T., & Malinowski, P. (2021) · Vibration · doi:10.3390/vibration4030033 · Cited by 84
“Figure 13 shows the comparison between this proposed method and another two widely used methods known as cluster approach (C-SHM) and a special module of sensor placement (SPEM) using effective independence (EFI) placement method [186] respectively in SHM.”
Method
Metadata
- Authors
- Li, B., Wang, D., Wang, F., & Ni, Y. Q.
- Venue
- 2010 Proceedings IEEE INFOCOM
- Publisher
- IEEE
- Published
- 2010-03
- Pages
- 1-9
- OpenAlex
- W2024316309
- Cited by
- 76
- References
- 1
- FWCI
- 36.95
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.