CARPO: Correlation-aware power optimization in data center networks
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Power optimization has become a key challenge in the design of large-scale enterprise data centers. Existing research efforts focus mainly on computer servers to lower their energy consumption, while only few studies have tried to address the energy consumption of data center networks (DCNs), which can account for 20% of the total energy consumption of a data center. In this paper, we propose CARPO, a correlation-aware power optimization algorithm that dynamically consolidates traffic flows onto a small set of links and switches in a DCN and then shuts down unused network devices for energy savings. In sharp contrast to existing work, CARPO is designed based on a key observation from the analysis of real DCN traces that the bandwidth demands of different flows do not peak at exactly the same time. As a result, if the correlations among flows are considered in consolidation, more energy savings can be achieved. In addition, CARPO integrates traffic consolidation with link rate adaptation for maximized energy savings. We implement CARPO on a hardware testbed composed of 10 virtual switches configured with a production 48-port OpenFlow switch and 8 servers. Our empirical results with Wikipedia traces demonstrate that CARPO can save up to 46% of network energy for a DCN, while having only negligible delay increases. CARPO also outperforms two state-of-the-art baselines by 19.6% and 95% on energy savings, respectively. Our simulation results with 61 flows also show the superior energy efficiency of CARPO over the baselines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A scalable, commodity data center network architecture
Al-Fares, M., Loukissas, A., & Vahdat, A. (2008) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1402946.1402967 · Cited by 3,175
A scalable, commodity data center network architecture
Al-Fares, M., Loukissas, A., & Vahdat, A. (2008) · Proceedings of the ACM SIGCOMM 2008 conference on Data communication · doi:10.1145/1402958.1402967 · Cited by 1,679 · cited 2×
“We use the fat tree structure [12] to construct the DCN in our simulation mainly for the purpose of comparison with ElasticTree.”
BackgroundMethodThe cost of a cloud: research problems in data center networks
Greenberg, A., Hamilton, J., Maltz, D. A., & Patel, P. (2008) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1496091.1496103 · Cited by 1,621 · cited 1×
“However, current research focuses mostly on computer servers to lower their energy consumption, while only few studies have tried to address the energy consumption of data center networks (DCNs), which can account for 10% to 20% of the total energy consumption of a data center [2], [3].”
BackgroundBCube: a high performance, server-centric network architecture for modular data centers
Guo, C., Lu, G., Li, D., Wu, H., Zhang, X., Shi, Y., Tian, C., Zhang, Y., & Lu, S. (2009) · Proceedings of the ACM SIGCOMM 2009 conference on Data communication · doi:10.1145/1592568.1592577 · Cited by 1,372 · cited 1×
“For example, novel DCN architectures have been proposed in [11], [12], [13], but those projects do not address DCN power consumption.”
BackgroundDcell: a scalable and fault-tolerant network structure for data centers
Guo, C., Wu, H., Tan, K., Shi, L., Zhang, Y., & Lu, S. (2008) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1402946.1402968 · Cited by 994
(2010) · doi:10.5555/1855711.1855728 · Cited by 970
Gupta, M., & Singh, S. (2003) · Proceedings of the 2003 conference on Applications, technologies, architectures, and protocols for computer communications · doi:10.1145/863955.863959 · Cited by 866 · cited 1×
“[9] have explored the possibility of putting network devices into sleep, such as switches and routers, when the traffic activities are low, to save the network device power.”
BackgroundReducing Network Energy Consumption via Sleeping and Rate-Adaptation
Nedevschi, S., Popa, L., Iannaccone, G., Ratnasamy, S., & Wetherall, D. J. (2008) · Cited by 661
Dcell: a scalable and fault-tolerant network structure for data centers
Guo, C., Wu, H., Tan, K., Shi, L., Zhang, Y., & Lu, S. (2008) · Proceedings of the ACM SIGCOMM 2008 conference on Data communication · doi:10.1145/1402958.1402968 · Cited by 563 · cited 1×
“For example, novel DCN architectures have been proposed in [11], [12], [13], but those projects do not address DCN power consumption.”
BackgroundUnderstanding data center traffic characteristics
Benson, T., Anand, A., Akella, A., & Zhang, M. (2010) · ACM SIGCOMM Computer Communication Review · doi:10.1145/1672308.1672325 · Cited by 548
Cited by
Big Data Meet Cyber-Physical Systems: A Panoramic Survey
Atat, R., Liu, L., Wu, J., Li, G., Ye, C., & Yang, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2878681 · Cited by 247
A Framework and Algorithm for Energy Efficient Container Consolidation in Cloud Data Centers
Piraghaj, S. F., Dastjerdi, A. V., Calheiros, R. N., & Buyya, R. (2015) · 2015 IEEE International Conference on Data Science and Data Intensive Systems · doi:10.1109/dsdis.2015.67 · Cited by 118
Toward Delay-Efficient Game-Aware Data Centers for Cloud Gaming
Amiri, M., Osman, H. A., Shirmohammadi, S., & Abdallah, M. (2016) · ACM Transactions on Multimedia Computing, Communications, and Applications · doi:10.1145/2983639 · Cited by 40
“…methods have been proposed to minimize the computational and network cost within a data center, these methods usually take into consideration either network status or computational resource status of servers [Wang et al. 2012; Beloglazov and Buyya 2010; Liu et al. 2009; Greenberg et al. 2008].”
Metadata
- Authors
- Wang, X., Yao, Y., Wang, X., Lu, K., & Cao, Q.
- Venue
- 2012 Proceedings IEEE INFOCOM
- Publisher
- IEEE
- Published
- 2012-03
- Pages
- 1125-1133
- OpenAlex
- W2106951600
- Cited by
- 167
- References
- 19
- FWCI
- 13.18
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CARPO: Correlation-aware power optimization in data center networks. https://app.cochat.ai/papers/10.1109/infcom.2012.6195471
- The paper
- Wang, X., Yao, Y., Wang, X., Lu, K., & Cao, Q. (2012). CARPO: Correlation-aware power optimization in data center networks. 2012 Proceedings IEEE INFOCOM. https://doi.org/10.1109/infcom.2012.6195471
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.