Joint power optimization of data center network and servers with correlation analysis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Data center power optimization has recently received a great deal of research attention. For example, server consolidation has been demonstrated as one of the most effective energy saving methodologies. Likewise, traffic consolidation has also been recently proposed to save energy for data center networks (DCNs). However, current research on data center power optimization focuses on servers and DCN separately. As a result, the optimization results are often inferior, because server consolidation without considering the DCN may cause traffic congestion and thus degraded network performance. On the other hand, server consolidation may change the DCN topology, allowing new opportunities for energy savings. In this paper, we propose PowerNetS, a power optimization strategy that leverages workload correlation analysis to jointly minimize the total power consumption of servers and the DCN. The design of PowerNetS is based on the key observations that the workloads of different servers and DCN traffic flows do not peak at exactly the same time. Thus, more energy savings can be achieved if the workload correlations are considered in server and traffic consolidations. In addition, PowerNetS considers the DCN topology during server consolidation, which leads to less inter-server traffic and thus more energy savings and shorter network delays. We implement PowerNetS on a hardware testbed composed of 10 virtual switches configured with a production 48-port OpenFlow switch and 6 servers. Our empirical results with Wikipedia, Yahoo!, and IBM traces demonstrate that PowerNetS can save up to 51.6% of energy for a data center. PowerNetS also outperforms two state-of-the-art baselines by 44.3% and 15.8% on energy savings, respectively. Our simulation results with 72 switches and 122 servers also show the superior energy efficiency of PowerNetS over the baselines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2010) · doi:10.5555/1855711.1855728 · Cited by 970
Cited by
Green IoT for Eco-Friendly and Sustainable Smart Cities: Future Directions and Opportunities
Almalki, F. A., Alsamhi, S. H., Sahal, R., Hassan, J., Hawbani, A., Rajput, N. S., Saif, A., Morgan, J., & Breslin, J. (2023) · Mobile Networks and Applications · doi:10.1007/s11036-021-01790-w · Cited by 376
A Framework and Algorithm for Energy Efficient Container Consolidation in Cloud Data Centers
Piraghaj, S. F., Dastjerdi, A. V., Calheiros, R. N., & Buyya, R. (2015) · 2015 IEEE International Conference on Data Science and Data Intensive Systems · doi:10.1109/dsdis.2015.67 · Cited by 118
“Unlike the extensive research on energy efficiency of computing [8], [9] and network resources [1], [10]–[12] for virtualized cloud data centers, only few works investigated the problem of energy efficient container management.”
BackgroundA whale optimization system for energy-efficient container placement in data centers
Al-Moalmi, A., Luo, J., Salah, A., Li, K., & Yin, L. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.113719 · Cited by 52
A hybrid approach for optimizing carbon footprint in intercloud environment
Justafort, V. D., Beaubrun, R., & Pierre, S. (2019) · IEEE Transactions on Services Computing · doi:10.1109/tsc.2016.2638900 · Cited by 7
Metadata
- Authors
- Zheng, K., Wang, X., Li, L., & Wang, X.
- Venue
- IEEE INFOCOM 2014 - IEEE Conference on Computer Communications
- Publisher
- IEEE
- Published
- 2014-04
- Pages
- 2598-2606
- OpenAlex
- W2001065285
- Cited by
- 130
- References
- 1
- FWCI
- 10.37
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Joint power optimization of data center network and servers with correlation analysis. https://app.cochat.ai/papers/10.1109/infocom.2014.6848207
- The paper
- Zheng, K., Wang, X., Li, L., & Wang, X. (2014). Joint power optimization of data center network and servers with correlation analysis. IEEE INFOCOM 2014 - IEEE Conference on Computer Communications. https://doi.org/10.1109/infocom.2014.6848207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.