Improving network security monitoring for industrial control systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Programmable Logic Controller (PLC) technology plays an important role in the automation architectures of several critical infrastructures such as Industrial Control Systems (ICS), controlling equipment in contexts such as chemical processes, factory lines, power production plants or power distribution grids, just to mention a few examples. Despite their importance, PLCs constitute one of the weakest links in ICS security, frequently due to reasons such as the absence of secure communication mechanisms, authenticated access or system integrity checks. While events such as the Stuxnet worm have raised awareness for this problem, industry has slowly reacted, either due to reliability or cost concerns. This paper introduces the Shadow Security Unit, a low-cost device deployed in parallel with a PLC or Remote Terminal Unit (RTU), being capable of transparently intercepting its communications control channels and physical process I/O lines to continuously assess its security and operational status. The proposed device does not require significant changes to the existing control network, being able to work in standalone or integrated within an ICS protection framework.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Taxonomy of Cyber Attacks on SCADA Systems
Zhu, B., Joseph, A., & Sastry, S. (2011) · 2011 International Conference on Internet of Things and 4th International Conference on Cyber, Physical and Social Computing · doi:10.1109/ithings/cpscom.2011.34 · Cited by 458
Cited by
Smart Cities: A Survey on Data Management, Security, and Enabling Technologies
Gharaibeh, A., Salahuddin, M. A., Hussini, S. J., Khreishah, A., Khalil, I., Guizani, M., & Al-Fuqaha, A. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2736886 · Cited by 628
“[307] proposes using a Shadow Security Unit that is capable of transparently intercepting communication channels and process I/O lines to monitor system security.”
MethodCyber-physical systems security: Limitations, issues and future trends
Yaacoub, J.-P. A., Salman, O., Noura, H. N., Kaaniche, N., Chehab, A., & Malli, M. (2020) · Microprocessors and Microsystems · doi:10.1016/j.micpro.2020.103201 · Cited by 491
Challenges and Opportunities in Securing the Industrial Internet of Things
Serror, M., Hack, S., Henze, M., Schuba, M., & Wehrle, K. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.3023507 · Cited by 362
Cybersecurity in industrial control systems: Issues, technologies, and challenges
Asghar, M. R., Hu, Q., & Zeadally, S. (2019) · Computer Networks · doi:10.1016/j.comnet.2019.106946 · Cited by 172
Nankya, M., Chataut, R., & Akl, R. (2023) · Sensors · doi:10.3390/s23218840 · Cited by 114
“This makes it feasible to establish a redundant security-checking mechanism that adopts a “black box” approach when assessing the behavior of the monitored devices [108].”
Background
Metadata
- Authors
- Cruz, T., Barrigas, J., Proenca, J., Graziano, A., Panzieri, S., Lev, L., & Simoes, P.
- Venue
- 2015 IFIP/IEEE International Symposium on Integrated Network Management (IM)
- Publisher
- IEEE
- Published
- 2015-05
- Pages
- 878-881
- OpenAlex
- W1528491666
- Cited by
- 56
- References
- 1
- FWCI
- 8.44
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving network security monitoring for industrial control systems. https://app.cochat.ai/papers/10.1109/inm.2015.7140399
- The paper
- Cruz, T., Barrigas, J., Proenca, J., Graziano, A., Panzieri, S., Lev, L., & Simoes, P. (2015). Improving network security monitoring for industrial control systems. 2015 IFIP/IEEE International Symposium on Integrated Network Management (IM). https://doi.org/10.1109/inm.2015.7140399
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.