The DOI matches its Crossref record.
Evaluation of 400V DC distribution in telco and data centers to improve energy efficiency
Abstract
In a typical data center, less than half the energy consumed is delivered to the compute load, with the rest lost in power conversion, distribution and cooling. Traditionally power distribution is at 400/480 V AC in data centers and at -48 V DC in telco facilities. Higher voltage DC has been proposed as an energy efficient distribution option for both types of facilities, and this paper presents an analytical evaluation of several data center power delivery architectures over a range of loads, showing that a 400 V facility-level DC distribution option is the most efficient. The equipment required to support such an architecture is discussed and results from a small scale demonstration are included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Kumar, D., Zare, F., & Ghosh, A. (2017) · IEEE Access · doi:10.1109/access.2017.2705914 · Cited by 751
DC microgrids and distribution systems: An overview
Elsayed, A. T., Mohamed, A. A., & Mohammed, O. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2014.10.017 · Cited by 590
Fei, C., Lee, F. C., & Li, Q. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674599 · Cited by 510
A Review of Solid-State Circuit Breakers
Rodrigues, R., Du, Y., Antoniazzi, A., & Cairoli, P. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3003358 · Cited by 456
Hossain, M. Z., Rahim, N. A., & Selvaraj, J. A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.017 · Cited by 305
High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC
Zhao, S., Li, Q., Lee, F. C., & Li, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2774440 · Cited by 231
99% Efficient Isolated Three-Phase Matrix-Type DAB Buck–Boost PFC Rectifier
Schrittwieser, L., Leibl, M., & Kolar, J. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2914488 · Cited by 169
Li, Z., Hsieh, E., Li, Q., & Lee, F. C. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3279030 · Cited by 111
Liu, Y.-C., Chen, C., Chen, K.-D., Syu, Y.-L., & Dung, N. A. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2953117 · Cited by 61
Metadata
- Authors
- Pratt, A., Kumar, P., & Aldridge, T. V.
- Venue
- INTELEC 07 - 29th International Telecommunications Energy Conference
- Publisher
- IEEE
- Published
- 2007
- Pages
- 32-39
- OpenAlex
- W2141401705
- Cited by
- 415
- References
- 0
- FWCI
- 14.60
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.