High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC
Open accessAbstract
This paper presents a high-frequency modular medium-voltage AC (4160 VAC or 13.8 kVAC) to low-voltage DC (400 VDC) system that is scalable in order to be used for different scale microgrids. A 15 kW, 500 kHz DC/DC converter is demonstrated as the most important stage of the system overall, which can be scalable to a 225 kW 4160 VAC to 400 VDC system. Motivation of a CLLC resonant converter and its design parameters determination is carefully illustrated. The high-frequency transformer is the key element for the DC/DC converter. Then, the paper focuses on high-frequency transformer design to realize high-voltage insulation, high efficiency, and high density at the same time. Based on a split winding UU core transformer structure, transformer insulation materials and dimension parameters are determined referring to the IEEE insulation standard. The transformer magnetic loss model is reviewed based on which loss design tradeoff is carefully analyzed. Different working frequency impact on transformer design over three different core materials is also presented. Finally, a 500 kHz transformer prototype has been developed and demonstrated with the IEEE standard required insulation tests. A whole CLLC resonant converter is also present with experiments results. The converter holds outstanding 98% efficiency and 2.9 kW/L power density.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642 · cited 1×
“To date, the cascaded H-bridge multilevel rectifier is deemed as a mature technology and can be directly applied to the proposed DC data center application [5].”
BackgroundOptimal choice for number of strands in a litz-wire transformer winding
Sullivan, C. R. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.750181 · Cited by 558
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478 · cited 7×
“Traditionally, the devices with the most use are high-voltage insulated gate bipolar transistors (IGBTs) [6], [7], [9], [10], [13], based on a three-level neutral point clamped (NPC) topology the 1.”
BackgroundMethodInfluentialEvaluation of 400V DC distribution in telco and data centers to improve energy efficiency
Pratt, A., Kumar, P., & Aldridge, T. V. (2007) · INTELEC 07 - 29th International Telecommunications Energy Conference · doi:10.1109/intlec.2007.4448733 · Cited by 415 · cited 1×
“Together, uninterruptible power system (UPS), power distribution unit (PDU), and power supply unit (PSU) will bring about a 21% loss of the total system power [2].”
BackgroundEdison Redux: 380 Vdc Brings Reliability and Efficiency to Sustainable Data Centers
AlLee, G., & Tschudi, W. (2012) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2012.2212607 · Cited by 273 · cited 1×
“In order to improve the power conversion efficiency inside the data center server hall, two approaches are proposed; one developing trend is to continue to use the AC distribution within the server hall with a paralleled UPS [3]; another approach is to, instead employ of the ac, using DC distribution within the server…”
MethodMedium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249 · cited 2×
“Traditionally, the devices with the most use are high-voltage insulated gate bipolar transistors (IGBTs) [6], [7], [9], [10], [13], based on a three-level neutral point clamped (NPC) topology the 1.”
BackgroundMultilevel intelligent universal transformer for medium voltage applications
Lai, J.-S., Maitra, A., Mansoor, A., & Goodman, F. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518705 · Cited by 185 · cited 2×
“Traditionally, the devices with the most use are high-voltage insulated gate bipolar transistors (IGBTs) [6], [7], [9], [10], [13], based on a three-level neutral point clamped (NPC) topology the 1.”
BackgroundDesign and Experimental Testing of a Resonant DC–DC Converter for Solid-State Transformers
Ortiz, G., Leibl, M. G., Huber, J. E., & Kolar, J. W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2637827 · Cited by 143 · cited 5×
“FREEDM Gen ETH Design CPES III [12] [14]–[16] Design”
BackgroundMethodInfluentialOrtiz, G., Leibl, M., Kolar, J. W., & Apeldoorn, O. (2013) · 2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2013.6527217 · Cited by 126 · cited 2×
“The most frequently used topology is the dual active bridge (DAB) converter [8], [9], [11], [15]; except ASEA brown”
MethodDesign and hardware implementation of Gen-1 silicon based solid state transformer
Wang, G., Baek, S., Elliott, J., Kadavelugu, A., Wang, F., She, X., Dutta, S., Liu, Y., Zhao, T., Yao, W., et al. (2011) · 2011 Twenty-Sixth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2011.5744766 · Cited by 99 · cited 5×
“Wang’s transformer is made up of a laminated amorphous (Metglas SA2605SA1) with 3 kHz working frequency and 7 kW rated power [9].”
BackgroundMethodInfluential
Research works printed but not linked: 5
- jaritz, 0, Isolation design of a 14.4�kV, 100�kHz transformer with a high isolation voltage (115�kV), Proc Power Modulator High Voltage Conf, 73
- 2005, Information Technology Equipment - Safety - Part 1 General Requirements
- 2015, General Requirements for Dry-Type Distribution and Power Transformers
- chanda, 2007, Plastic Technology Handbook
- 2014, National Electrical Code, 70
Cited by
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Khalid, M. R., Khan, I. A., Hameed, S., Asghar, M. S. J., & Ro, J. (2021) · IEEE Access · doi:10.1109/access.2021.3112189 · Cited by 353
99% Efficient 10 kV SiC-Based 7 kV/400 V DC Transformer for Future Data Centers
Rothmund, D., Guillod, T., Bortis, D., & Kolar, J. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2886139 · Cited by 315
Insulating materials for realising carbon neutrality: Opportunities, remaining issues and challenges
Li, C., Yang, Y., Xu, G., Zhou, Y., Jia, M., Zhong, S., Gao, Y., Park, C., Liu, Q., Wang, Y., et al. (2022) · High Voltage · doi:10.1049/hve2.12232 · Cited by 227
“In the case of high‐frequency transformers, which provide galvanic isolation in MVDC PEC‐driven systems, one of the factors that limits the size reduction potential enabled by the high‐frequency switching of WBG power modules is electrical insulation [120, 121].”
BackgroundAhmad, A., Qin, Z., Wijekoon, T., & Bauer, P. (2022) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2022.3179743 · Cited by 160
“amount of reactive power that circulates in the converter, as the sinusoidal resonant current puts less stress on the M/HFT than the DAB converter’s [171].”
Background
Metadata
- Authors
- Zhao, S., Li, Q., Lee, F. C., & Li, B.
- Affiliations
- Virginia Tech (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-09
- Volume
- 33
- Issue
- 9
- Pages
- 7545-7557
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2770903482
- Cited by
- 231
- References
- 21
- Citations by year
- 2026: 12 · 2025: 17 · 2024: 30 · 2023: 31 · 2022: 37 · 2021: 46 · 2020: 23 · 2019: 22 · 2018: 11
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- Office of Energy Efficiency and Renewable Energy, U.S. Department of Energy (DE-EE0006521)
- Virginia Polytechnic Institute and State University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- high-frequency transformer design, CLLC resonant converter, DC-DC converter, modular power conversion, microgrids, transformer insulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC. https://app.cochat.ai/papers/10.1109/tpel.2017.2774440
- The paper
- Zhao, S., Li, Q., Lee, F. C., & Li, B. (2018). High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2017.2774440
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.