SiC-based unidirectional solid-state transformer concepts for directly interfacing 400V DC to Medium-Voltage AC distribution systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
400 V DC distribution networks present a promising solution for supplying high-power DC loads such as information processing systems, transportation battery charging facilities and DC micro grids, among others. For these applications, high transmission efficiency, reliability and controllability are mandatory. With the current technology, these loads are fed from PWM rectifiers which are connected to the three-phase Low-Voltage (LV) distribution grid (400 V AC in Europe). The LV grid itself is supplied via Low-Frequency Transformers (LFT) from the Medium-Voltage (MV) grid, providing galvanic isolation and the required voltage step down. This paper presents three unidirectional AC/DC SiC-based Solid-State Transformer (SST) topologies with direct connection to the MV grid, which avoid the utilization of the aforementioned LFT by integrating a Medium-Frequency (MF) conversion stage, thus increasing the efficiency and power density of this supply system. The SST topologies are compared by means of a chip area-based comparative evaluation. Finally, the most suited among the presented topologies is Pareto-optimized, achieving a total MV AC to 400 V DC efficiency of 98.3 %. It is shown that the optimized SST features 40 % less overall losses compared to state-of-the-art solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Essence of Three-Phase PFC Rectifier Systems—Part I
Kolar, J. W., & Friedli, T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2197867 · Cited by 788 · cited 2×
“According to [22], the relative MOSFET and diode RMS ratings are defined as”
BackgroundSelf-citation
Cited by
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Kumar, D., Zare, F., & Ghosh, A. (2017) · IEEE Access · doi:10.1109/access.2017.2705914 · Cited by 751
99% Efficient 10 kV SiC-Based 7 kV/400 V DC Transformer for Future Data Centers
Rothmund, D., Guillod, T., Bortis, D., & Kolar, J. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2886139 · Cited by 315
Self-citationFull-ZVS modulation for all-SiC ISOP-type isolated front end (IFE) solid-state transformer
Huber, J. E., Rothmund, D., Wang, L., & Kolar, J. W. (2016) · 2016 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855128 · Cited by 31
Self-citationMadhusoodhanan, S., Mainali, K., Tripathi, A., Patel, D., Kadavelugu, A., Bhattacharya, S., & Hatua, K. (2015) · 2015 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310184 · Cited by 13
Metadata
- Authors
- Rothmund, D., Ortiz, G., & Kolar, J. W.
- Venue
- 2014 IEEE 36th International Telecommunications Energy Conference (INTELEC)
- Publisher
- IEEE
- Published
- 2014-09
- Pages
- 1-9
- OpenAlex
- W2325001167
- Cited by
- 57
- References
- 1
- FWCI
- 7.31
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.