Comparative evaluation of isolated front end and isolated back end multi-cell SSTs
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Solid-state transformers (SSTs) are power electronic interfaces between medium voltage (MV) and low voltage (LV) systems that provide galvanic isolation by means of medium frequency (MF) transformers, making them suitable for MVAC to LVDC conversion in environments where weight and volume constraints apply. This paper discusses an isolated front end (IFE) SST concept that allows to reduce the complexity and physical size of the MV side converter assemblies compared to the well-known isolated back end (IBE) SST topologies. The IFE approach performs the entire grid current and output voltage control on the LV side using standard non-isolated |AC|-DC boost converter stages. A generic comparison of the IFE and the IBE concepts reveals that the lower complexity of the IFE, e. g., a lower total MV blocking voltage requirement (number of cascaded cells), comes along with higher device RMS currents and hence slightly higher chip area requirements. On the other hand, a case study considering a 25kW, 6.6 kV AC to 400V DC SST shows advantages of the IFE in part-load operation due to lower switching and transformer core losses. This makes the IFE approach interesting for applications where MF isolation instead of low frequency isolation is required because of space and weight constraints (e. g., traction, subsea or aircraft environments), and where low system complexity is desirable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Huber, J. E., & Kolar, J. W. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6954023 · Cited by 264
Self-citationMedium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249
New Bidirectional Intelligent Semiconductor Transformer for Smart Grid Application
Han, B.-M., Choi, N.-S., & Lee, J.-Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2284009 · Cited by 37
Cited by
Applicability of solid-state transformers in today's and future distribution grids
Huber, J. E., & Kolar, J. W. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2738610 · Cited by 506
“, climate control units [57].”
Self-citationSolid-State Transformers: On the Origins and Evolution of Key Concepts
Huber, J. E., & Kolar, J. W. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2588878 · Cited by 449
“(However, one has to note that operation with power factors differing from unity is possible but results in disturbances in the grid current [39].”
BackgroundResultInfluentialSelf-citationFull-ZVS modulation for all-SiC ISOP-type isolated front end (IFE) solid-state transformer
Huber, J. E., Rothmund, D., Wang, L., & Kolar, J. W. (2016) · 2016 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855128 · Cited by 31
Self-citation
Metadata
- Authors
- Huber, J. E., Rothmund, D., & Kolar, J. W.
- Venue
- 2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)
- Publisher
- IEEE
- Published
- 2016-05
- Pages
- 3536-3545
- OpenAlex
- W2465785827
- Cited by
- 47
- References
- 4
- FWCI
- 5.65
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.