Evaluation of zero-velocity detectors for foot-mounted inertial navigation systems
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
A study of the performance of four zero-velocity detectors for a foot-mounted inertial sensor based pedestrian navigation system is presented. The four detectors are the acceleration moving variance detector, the acceleration magnitude detector, the angular rate energy detector, and a novel generalized likelihood ratio test detector, refereed to as the SHOE. The performance of each detector is assessed by the accuracy of the position solution provided by the navigation system employing the detector to perform zero-velocity updates. The results show that for leveled ground forward gait at a speed of 5 km/h, the angular rate energy detector and the SHOE give the highest performance, with a position accuracy of 0.14% of the travelled distance. The results also indicate that during leveled ground forward gait, the gyroscope signals hold the most reliable information for zero-velocity detection.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The angular rate energy (ARE) detector [40] is computationally one of the lightest and provides the highest position accuracies; and, it is one of the most robust to changes in gait speed.”
From A wearable system for gait training in subjects with Parkinson's disease (2014) · cites this paper as [40]
Citations
Cites
Fundamentals of Statistical Signal Processing: Estimation Theory
Sengijpta, S. K. (1995) · Technometrics · doi:10.1080/00401706.1995.10484391 · Cited by 11,076
Pedestrian Tracking with Shoe-Mounted Inertial Sensors
Foxlin, E. (2005) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2005.140 · Cited by 1,399 · cited 1×
“Details on the implementation of a zerovelocity aided inertial navigation system can be found in [11].”
BackgroundZero-Velocity Detection—An Algorithm Evaluation
Skog, I., Handel, P., Nilsson, J. O., & Rantakokko, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2060723 · Cited by 662 · cited 4×
“In the study presented in this paper, we extend the work in [7] by looking at how the choice of a zero-velocity detector and the properties of the detector affect IMU”
BackgroundMethodInfluentialSelf-citationDetection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491 · cited 2×
“It was shown that the acceleration moving variance (MV) detector [1]–[4], [8], the acceleration magnitude (MAG) detector [2], [4], [8], and the angular rate energy (ARE) detector [5], [6], [8]–[10], are all generalized likelihood ratio tests; the difference is the assumed prior knowledge about the signals from the IMU…”
BackgroundJimenez, A. R., Seco, F., Prieto, J. C., & Guevara, J. (2010) · 2010 7th Workshop on Positioning, Navigation and Communication · doi:10.1109/wpnc.2010.5649300 · Cited by 469 · cited 1×
“It was shown that the acceleration moving variance (MV) detector [1]–[4], [8], the acceleration magnitude (MAG) detector [2], [4], [8], and the angular rate energy (ARE) detector [5], [6], [8]–[10], are all generalized likelihood ratio tests; the difference is the assumed prior knowledge about the signals from the IMU…”
BackgroundFoot mounted inertial system for pedestrian navigation
Godha, S., & Lachapelle, G. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/7/075202 · Cited by 230 · cited 1×
“It was shown that the acceleration moving variance (MV) detector [1]–[4], [8], the acceleration magnitude (MAG) detector [2], [4], [8], and the angular rate energy (ARE) detector [5], [6], [8]–[10], are all generalized likelihood ratio tests; the difference is the assumed prior knowledge about the signals from the IMU…”
BackgroundPedestrian tracking using inertial sensors
Feliz Alonso, R., Zalama Casanova, E., & Gómez García-Bermejo, J. (2009) · Journal of Physical Agents (JoPha) · doi:10.14198/jopha.2009.3.1.05 · Cited by 228 · cited 1×
“It was shown that the acceleration moving variance (MV) detector [1]–[4], [8], the acceleration magnitude (MAG) detector [2], [4], [8], and the angular rate energy (ARE) detector [5], [6], [8]–[10], are all generalized likelihood ratio tests; the difference is the assumed prior knowledge about the signals from the IMU…”
BackgroundNon-GPS navigation for security personnel and first responders
Ojeda, L., & Borenstein, J. (2007) · Journal of Navigation · doi:10.1017/s0373463307004286 · Cited by 226 · cited 2×
“It was shown that the acceleration moving variance (MV) detector [1]–[4], [8], the acceleration magnitude (MAG) detector [2], [4], [8], and the angular rate energy (ARE) detector [5], [6], [8]–[10], are all generalized likelihood ratio tests; the difference is the assumed prior knowledge about the signals from the IMU…”
BackgroundPersonal Navigation via High-Resolution Gait-Corrected Inertial Measurement Units
Bebek, Ö., Suster, M. A., Rajgopal, S., Fu, M. J., Huang, X., Cavusoglu, M. C., Young, D. J., Mehregany, M., van den Bogert, A. J., & Mastrangelo, C. H. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2046595 · Cited by 160
Integrated GPS/INS System for Pedestrian Navigation in a Signal Degraded Environment
Godha, S., Lachapelle, G., Cannon, M. E., & Godha, S. (2006) · Cited by 153
Cited by
Zero-Velocity Detection—An Algorithm Evaluation
Skog, I., Handel, P., Nilsson, J. O., & Rantakokko, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2060723 · Cited by 662
Self-citationWearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
“[54] compared four different detectors to identify the zero velocity interval—”acceleration moving variance detector, the acceleration magnitude detector, the angular rate energy (ARE) detector, and a generalized likelihood ratio test detector, referred to as the SHOE”—and concluded that both ARE and SHOE performed wi…”
BackgroundStance-Phase Detection for ZUPT-Aided Foot-Mounted Pedestrian Navigation System
Wang, Z., Zhao, H., Qiu, S., & Gao, Q. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2430357 · Cited by 196
“Extra sensors in addition to the IMU have been used to aid the stance-phase detection, such as radio frequency sensors, cameras, and pressure sensors [8], [13], [14].”
BackgroundMethodHeel and Toe Clearance Estimation for Gait Analysis Using Wireless Inertial Sensors
Mariani, B., Rochat, S., Büla, C. J., & Aminian, K. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2216263 · Cited by 191
“riod (foot-flat), which validity has been recently evaluated [19].”
BackgroundFourati, H. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2335912 · Cited by 160
“To detect a stance phase based on a gyroscope signal, we used the following angular rate energy detector [9], [32]:”
BackgroundMethod
Metadata
- Authors
- Skog, I., Nilsson, J.-O., & Handel, P.
- Affiliations
- KTH Royal Institute of Technology (SE)
- ORCID
- Skog, Isaac
- Venue
- 2010 International Conference on Indoor Positioning and Indoor Navigation
- Publisher
- IEEE
- Published
- 2010-09
- Pages
- 1-6
- ISSN
- 2162-7347 (ISSN-L)
- OpenAlex
- W2004814601
- Cited by
- 213
- References
- 15
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 14 · 2023: 15 · 2022: 12 · 2021: 19 · 2020: 16 · 2019: 19 · 2018: 16 · 2017: 14 · 2016: 15 · 2015: 14 · 2014: 17 · 2013: 12 · 2012: 13
- FWCI
- 21.03
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Indoor Positioning and Indoor Navigation (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Indoor and Outdoor Localization Technologies
- Physical Sciences › Computer Science › Artificial Intelligence › Target Tracking and Data Fusion in Sensor Networks
- Keywords
- zero-velocity detection, pedestrian navigation, inertial sensors, generalized likelihood ratio test, positioning accuracy, gait
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.