The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Heel and Toe Clearance Estimation for Gait Analysis Using Wireless Inertial Sensors
Open accessAbstract
Tripping is considered a major cause of fall in older people. Therefore, foot clearance (i.e., height of the foot above ground during swing phase) could be a key factor to better understand the complex relationship between gait and falls. This paper presents a new method to estimate clearance using a foot-worn and wireless inertial sensor system. The method relies on the computation of foot orientation and trajectory from sensors signal data fusion, combined with the temporal detection of toe-off and heel-strike events. Based on a kinematic model that automatically estimates sensor position relative to the foot, heel and toe trajectories are estimated. 2-D and 3-D models are presented with different solving approaches, and validated against an optical motion capture system on 12 healthy adults performing short walking trials at self-selected, slow, and fast speed. Parameters corresponding to local minimum and maximum of heel and toe clearance were extracted and showed accuracy ± precision of 4.1 ± 2.3 cm for maximal heel clearance and 1.3 ± 0.9 cm for minimal toe clearance compared to the reference. The system is lightweight, wireless, easy to wear and to use, and provide a new and useful tool for routine clinical assessment of gait outside a dedicated laboratory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of zero-velocity detectors for foot-mounted inertial navigation systems
Skog, I., Nilsson, J.-O., & Handel, P. (2010) · 2010 International Conference on Indoor Positioning and Indoor Navigation · doi:10.1109/ipin.2010.5646936 · Cited by 213
Cited by
A Survey of Wearable Devices and Challenges
Seneviratne, S., Hu, Y., Nguyen, T., Lan, G., Khalifa, S., Thilakarathna, K., Hassan, M., & Seneviratne, A. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2731979 · Cited by 821
Detecting Falls with Wearable Sensors Using Machine Learning Techniques
Özdemir, A., & Barshan, B. (2014) · Sensors · doi:10.3390/s140610691 · Cited by 375
Wearable sensors objectively measure gait parameters in Parkinson’s disease
Schlachetzki, J. C. M., Barth, J., Marxreiter, F., Gossler, J., Kohl, Z., Reinfelder, S., Gassner, H., Aminian, K., Eskofier, B. M., Winkler, J., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0183989 · Cited by 333
Self-citationKobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Wenger, N., Moraud, E. M., Raspopovic, S., Bonizzato, M., DiGiovanna, J., Musienko, P., Morari, M., Micera, S., & Courtine, G. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008325 · Cited by 209
Metadata
- Authors
- Mariani, B., Rochat, S., Büla, C. J., & Aminian, K.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-11
- Volume
- 59
- Issue
- 11
- Pages
- 3162-3168
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1979899459
- Cited by
- 191
- References
- 1
- FWCI
- 25.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heel and Toe Clearance Estimation for Gait Analysis Using Wireless Inertial Sensors. https://app.cochat.ai/papers/10.1109/tbme.2012.2216263
- The paper
- Mariani, B., Rochat, S., Büla, C. J., & Aminian, K. (2012). Heel and Toe Clearance Estimation for Gait Analysis Using Wireless Inertial Sensors. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2216263
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.