THz spectrometry measurements often exhibit high uncertainties that have previously been attributed to noise. The normalized uncertainties (1-σ) for three signal processing strategies were evaluated using 40 waveform acquisitions of water vapor (0-3 THz). Time-alignment gives ×80 improvement at 1 THz compared with averaging of all results whereas trace rejection strategies only improve the results by ×3.4.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, these errors can be eliminated by software or hardware solutions. Algorithms are used to correct the time shift in a series of measured THz pulses [20,21]. Interferometers are used to more accurately measure the delay line position [22].”
From Correction of Optical Delay Line Errors in Terahertz Time-Domain Spectroscopy (2019) · cites this paper as [20]
In the citing paper
“Residual THz time drift can be algorithmically compensated by time shift and interpolation of the signals [20,21].”
From Correction of Optical Delay Line Errors in Terahertz Time-Domain Spectroscopy (2019) · cites this paper as [20]
Citations
Cites
Dynamic range in terahertz time-domain transmission and reflection spectroscopy
Jepsen, P. U., & Fischer, B. M. (2005) · Optics Letters · doi:10.1364/ol.30.000029 · Cited by 382
The Measurement and Deconvolution of Time Jitter in Equivalent-Time Waveform Samplers
Gans, W. L. (1983) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1983.4315022 · Cited by 121
Traceable Waveform Calibration With a Covariance-Based Uncertainty Analysis
Hale, P. D., Dienstfrey, A., Wang, J., Williams, D. F., Lewandowski, A., Keenan, D. A., & Clement, T. S. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2018012 · Cited by 59
Coakley, K. J., & Hale, P. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.903892 · Cited by 52
Vandersteen, G., Rolain, Y., & Schoukens, J. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.963210 · Cited by 39
Principal Component Compression Method for Covariance Matrices Used for Uncertainty Propagation
Humphreys, D. A., Harris, P. M., Rodriguez-Higuero, M., Mubarak, F. A., Zhao, D., & Ojasalo, K. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2340640 · Cited by 29
Self-citationDynamic range improvement of THz spectroscopy
Humphreys, D. A., & Naftaly, M. (2014) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2014.6898580 · Cited by 3
Self-citation
Research works printed but not linked: 1
- humphreys, 1990, Measurement Techniques Numerical Methods and Photodiode Risetime Transfer Standards for Picosecond Optoelectronic Device Metrology at 1-1 6 ?m
Cited by
Principal Component Compression Method for Covariance Matrices Used for Uncertainty Propagation
Humphreys, D. A., Harris, P. M., Rodriguez-Higuero, M., Mubarak, F. A., Zhao, D., & Ojasalo, K. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2340640 · Cited by 29
Self-citationCorrection of Optical Delay Line Errors in Terahertz Time-Domain Spectroscopy
Mamrashev, A., Minakov, F., Maximov, L., Nikolaev, N., & Chapovsky, P. (2019) · Electronics · doi:10.3390/electronics8121408 · Cited by 20
“Residual THz time drift can be algorithmically compensated by time shift and interpolation of the signals [20,21].”
BackgroundMethodMulti-Period Fast Rotating Optical Delay Line With 228.47 ps Delay Time
Zhu, L., Xue, J., Ren, J., Zhang, D., Gu, J., Zhang, J., & Li, L. (2024) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2024.3371498 · Cited by 4
Nonlinear error analysis of fast optical delay lines
Zhu, L., Xue, J., Ren, J., Zhang, D., Gu, J., Zhang, J., & Li, L. (2024) · Applied Optics · doi:10.1364/ao.513722 · Cited by 3
Báez-Chorro, M. A., & Vidal, B. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3162146 · Cited by 2
Metadata
- Authors
- Humphreys, D. A., Naftaly, M., & Molloy, J. F.
- Affiliations
- National Physical Laboratory (GB)
- Heriot-Watt University (GB)
- Venue
- 2014 39th International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz)
- Publisher
- IEEE
- Published
- 2014-09
- Pages
- 1-2
- OpenAlex
- W2328976580
- Semantic Scholar
- 452a28945c1e3356c7ad4e7086c5d05508b3026f
- Cited by
- 9
- References
- 7
- Citations by year
- 2026: 1 · 2024: 3 · 2022: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2014: 1
- FWCI
- 0.81
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
- Keywords
- time delay error, terahertz spectroscopy, dynamic range, measurement uncertainty, temporal alignment, signal averaging, water vapor, waveform acquisition
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of time-delay errors on THz spectroscopy dynamic range. https://app.cochat.ai/papers/10.1109/irmmw-thz.2014.6956138
- The paper
- Humphreys, D. A., Naftaly, M., & Molloy, J. F. (2014). Effect of time-delay errors on THz spectroscopy dynamic range. 2014 39th International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz). https://doi.org/10.1109/irmmw-thz.2014.6956138
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.