The DOI matches its Crossref record.
Development and control of a hand exoskeleton for rehabilitation of hand injuries
Abstract
Hand injuries are a frequent problem. The great amount of hand injuries is not only a problem for the affected people but economic consequences follow because rehabilitation takes a long time. Physical therapy after an operation is associated with high personnel expenses. To improve therapy results and reduce cost of rehabilitation a hand exoskeleton was developed. The hand exoskeleton was specifically designed to accomplish requirements of medical applications. For research on control algorithms and rehabilitation programs a prototype supporting all four degrees of freedom of one finger was build. The device can be easily attached and also be adjusted to deformed and scarred hands. In view of the fact that a lot of hand injuries affect only one finger, this prototype could already be functional in physical therapy. This paper presents the construction and the control system of the hand exoskeleton and possible applications in therapy of hand injuries. For the position control a PID controller was implemented and evaluated. The resulting control system allows following of recorded trajectories with sufficient accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2362863 · Cited by 473
An EMG-Controlled Robotic Hand Exoskeleton for Bilateral Rehabilitation
Leonardis, D., Chisari, C., Bergamasco, M., Frisoli, A., Barsotti, M., Loconsole, C., Solazzi, M., Troncossi, M., Mazzotti, C., Castelli, V. P., et al. (2015) · IEEE Transactions on Haptics · doi:10.1109/toh.2015.2417570 · Cited by 339
Metadata
- Authors
- Wege, A., & Hommel, G.
- Venue
- 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2005
- Pages
- 3046-3051
- OpenAlex
- W2057687952
- Cited by
- 221
- References
- 0
- FWCI
- 10.10
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and control of a hand exoskeleton for rehabilitation of hand injuries. https://app.cochat.ai/papers/10.1109/iros.2005.1545506
- The paper
- Wege, A., & Hommel, G. (2005). Development and control of a hand exoskeleton for rehabilitation of hand injuries. 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems. https://doi.org/10.1109/iros.2005.1545506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.