The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
Abstract
Soft wearable robots are good alternatives to rigid-frame exoskeletons because they are compact and lightweight. This article describes a soft wearable hand robot called the Exo-Glove that uses a soft tendon routing system and an underactuation adaptive mechanism. The proposed system can be used to develop other types of soft wearable robots. The glove part of the system is compact and weighs 194 g. The results conducted using a healthy subject showed sufficient performance for the execution of daily life activities, namely a pinch force of 20 N, a wrap grasp force of 40 N, and a maximum grasped object size of 76 mm. The use of an underactuation mechanism enabled the grasping of objects of various shapes without active control. A subject suffering from paralysis of the hands due to a spinal cord injury was able to use the glove to grasp objects of various shapes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Compared with pneumatic actuating methods, tendon driven grippers have a higher grasping speed and strength.[484,485]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [485]
Citations
Cites
THE RESTORATION OF MOTOR FUNCTION FOLLOWING HEMIPLEGIA IN MAN
TWITCHELL, T. E. (1951) · Brain · doi:10.1093/brain/74.4.443 · Cited by 940
Gulati, S., & Sondhi, V. (2018) · The Indian Journal of Pediatrics · doi:10.1007/s12098-017-2475-1 · Cited by 733
Snoek, G. J., IJzerman, M. J., Hermens, H. J., Maxwell, D., & Biering-Sorensen, F. (2004) · Spinal Cord · doi:10.1038/sj.sc.3101638 · Cited by 523
Krigger, K. W. (2006) · PubMed · Cited by 373
Chiri, A., Vitiello, N., Giovacchini, F., Roccella, S., Vecchi, F., & Carrozza, M. C. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2144614 · Cited by 254
Biologically-inspired soft exosuit
Asbeck, A. T., Dyer, R. J., Larusson, A. F., & Walsh, C. J. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650455 · Cited by 240
Development and control of a hand exoskeleton for rehabilitation of hand injuries
Wege, A., & Hommel, G. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545506 · Cited by 221
Functional anatomy of the human digital flexor pulley system
Lin, G.-T., Amadio, P. C., An, K.-N., & Cooney, W. P. (1989) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(89)80043-7 · Cited by 186
Identification of key pinch forces required to complete functional tasks
Smaby, N., Johanson, M. E., Baker, B., Kenney, D. E., Murray, W. M., & Hentz, V. R. (2004) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2004.02.0215 · Cited by 171
An Actuated Finger Exoskeleton for Hand Rehabilitation Following Stroke
Worsnopp, T., Peshkin, M. A., Colgate, J. E., & Kamper, D. G. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428530 · Cited by 146
Research works printed but not linked: 2
- 0, Idrogenet srl (2014) Gloreha
- crandall, 1999, An Introduction to the Mechanics of Solids Second Edition with SI Units
Cited by
Soft robotics: Technologies and systems pushing the boundaries of robot abilities
Laschi, C., Mazzolai, B., & Cianchetti, M. (2016) · Science Robotics · doi:10.1126/scirobotics.aah3690 · Cited by 1,570
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Zhu, M., Sun, Z., Zhang, Z., Shi, Q., He, T., Liu, H., Chen, T., & Lee, C. (2020) · Science Advances · doi:10.1126/sciadv.aaz8693 · Cited by 784
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Metadata
- Authors
- In, H., Kang, B. B., Sin, M., & Cho, K.-J.
- Affiliations
- Seoul National University (KR)
- Venue
- IEEE Robotics & Automation Magazine
- Published
- 2015-03
- Volume
- 22
- Issue
- 1
- Pages
- 97-105
- ISSN
- 1070-9932 (ISSN-L)
- OpenAlex
- W1994380917
- Cited by
- 473
- References
- 19
- Citations by year
- 2026: 26 · 2025: 44 · 2024: 31 · 2023: 45 · 2022: 43 · 2021: 50 · 2020: 55 · 2019: 60 · 2018: 47 · 2017: 34 · 2016: 24 · 2015: 11
- FWCI
- 19.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Robotics & Automation Magazine (publishedVersion)
- Funders
- National Rehabilitation Center
- National Research Foundation of Korea
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- soft wearable robots, hand exoskeleton, underactuation, adaptive mechanisms, grasping, pinch strength, object grasping, spinal cord injury, hand paralysis, assistive robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System. https://app.cochat.ai/papers/10.1109/mra.2014.2362863
- The paper
- In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015). Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System. IEEE Robotics & Automation Magazine. https://doi.org/10.1109/mra.2014.2362863
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.