Multisensory five-finger dexterous hand: The DLR/HIT Hand II
Abstract
This paper presents a new developed multisensory five-fingered dexterous robot hand: the DLR/HIT Hand II. The hand has an independent palm and five identical modular fingers, each finger has three DOFs and four joints. All the actuators and electronics are integrated in the finger body and the palm. By using powerful super flat brushless DC motors, tiny harmonic drivers and BGA form DSPs and FPGAs, the whole fingerpsilas size is about one third smaller than the former finger in the DLR/HIT Hand I. By using the steel coupling mechanism, the phalanx distalpsilas transmission ratio is exact 1:1 in the whole movement range. At the same time, the multisensory dexterous hand integrates position, force/torque and temperature sensors. The hierarchical hardware structure of the hand consists of the finger DSPs, the finger FPGAs, the palm FPGA and the PCI based DSP/FPGA board. The hand can communicate with external with PPSeCo, CAN and Internet. Instead of extra cover, the packing mechanism of the hand is implemented directly in the finger body and palm to make the hand smaller and more human like. The whole weight of the hand is about 1.5Kg and the fingertip force can reach 10N.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DLR-Hand II: next generation of a dextrous robot hand
Butterfass, J., Grebenstein, M., Liu, H., & Hirzinger, G. (2002) · Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164) · doi:10.1109/robot.2001.932538 · Cited by 808
Self-citation
Cited by
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 716
Multichannel electrotactile feedback for simultaneous and proportional myoelectric control
Patel, G. K., Dosen, S., Castellini, C., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056015 · Cited by 58
Jiralerspong, T., Nakanishi, E., Liu, C., & Ishikawa, J. (2017) · Applied Sciences · doi:10.3390/app7111163 · Cited by 30
Metadata
- Authors
- Liu, H., Wu, K., Meusel, P., Seitz, N., Hirzinger, G., Jin, M. H., Liu, Y. W., Fan, S. W., Lan, T., & Chen, Z. P.
- Venue
- 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2008-09
- Pages
- 3692-3697
- OpenAlex
- W1984237968
- Cited by
- 360
- References
- 1
- FWCI
- 14.78
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multisensory five-finger dexterous hand: The DLR/HIT Hand II. https://app.cochat.ai/papers/10.1109/iros.2008.4650624
- The paper
- Liu, H., Wu, K., Meusel, P., Seitz, N., Hirzinger, G., Jin, M. H., Liu, Y. W., Fan, S. W., Lan, T., & Chen, Z. P. (2008). Multisensory five-finger dexterous hand: The DLR/HIT Hand II. 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems. https://doi.org/10.1109/iros.2008.4650624
Data sources