The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Abstract
In this article, we set forth a detailed analysis of the mechanical characteristics of anthropomorphic prosthetic hands. We report on an empirical study concerning the performance of several commercially available myoelectric prosthetic hands, including the Vincent, iLimb, iLimb Pulse, Bebionic, Bebionic v2, and Michelangelo hands. We investigated the finger design and kinematics, mechanical joint coupling, and actuation methods of these commercial prosthetic hands. The empirical findings are supplemented with a compilation of published data on both commercial and prototype research prosthetic hands. We discuss numerous mechanical design parameters by referencing examples in the literature. Crucial design trade-offs are highlighted, including number of actuators and hand complexity, hand weight, and grasp force. Finally, we offer a set of rules of thumb regarding the mechanical design of anthropomorphic prosthetic hands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
Birglen, L., Laliberté, T., & Gosselin, C. (2008) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-540-77459-4 · Cited by 572
The Highly Adaptive SDM Hand: Design and Performance Evaluation
Dollar, A. M., & Howe, R. D. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364909360852 · Cited by 529
Self-citationConsumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
INVESTIGATION OF INERTIAL PROPERTIES OF THE HUMAN BODY
Chandler, R. F., Clauser, C. E., McConville, J. T., Reynolds, H. M., & Young, J. W. (1975) · Defense Technical Information Center (DTIC) · Cited by 515
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Multisensory five-finger dexterous hand: The DLR/HIT Hand II
Liu, H., Wu, K., Meusel, P., Seitz, N., Hirzinger, G., Jin, M. H., Liu, Y. W., Fan, S. W., Lan, T., & Chen, Z. P. (2008) · 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2008.4650624 · Cited by 360
Design and development of an underactuated prosthetic hand
Massa, B., Roccella, S., Carrozza, M. C., & Dario, P. (2003) · Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) · doi:10.1109/robot.2002.1014232 · Cited by 333
The statistics of natural hand movements
Ingram, J. N., Körding, K. P., Howard, I. S., & Wolpert, D. M. (2008) · Experimental Brain Research · doi:10.1007/s00221-008-1355-3 · Cited by 330
Multiple finger, passive adaptive grasp prosthetic hand
Dechev, N., Cleghorn, W. L., & Naumann, S. (2001) · Mechanism and Machine Theory · doi:10.1016/s0094-114x(01)00035-0 · Cited by 304
Cited by
Tactile sensing in dexterous robot hands — Review
Kappassov, Z., Corrales, J.-A., & Perdereau, V. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.07.015 · Cited by 782
A compliant, underactuated hand for robust manipulation
Odhner, L. U., Jentoft, L. P., Claffee, M. R., Corson, N., Tenzer, Y., Ma, R. R., Buehler, M., Kohout, R., Howe, R. D., & Dollar, A. M. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364913514466 · Cited by 598
Self-citationA soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
Piazza, C., Grioli, G., Catalano, M. G., & Bicchi, A. (2019) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-105003 · Cited by 332
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citation
Metadata
- Authors
- Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2013
- Volume
- 50
- Issue
- 5
- Pages
- 599
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2104544700
- Cited by
- 716
- References
- 26
- FWCI
- 20.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review. https://app.cochat.ai/papers/10.1682/jrrd.2011.10.0188
- The paper
- Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013). Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review. The Journal of Rehabilitation Research and Development. https://doi.org/10.1682/jrrd.2011.10.0188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.