Cooperative walk control of paraplegia patient and assistive system
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper introduces a cooperative control algorithm that designs a stable biped walk satisfying a wearer's intention relating to his/her walk such as a timings to start and stop walking, walking speed and waking direction. Using this algorithm an exoskeletal walking support system could help a paraplegia patient walking comfortablly. At first, a pair of gloves with several DOFs is developed to convey a wearer's intention to the walking support system. He/she swings both his/her index fingers as to simulate foot motions of his/her walking. The amplitude and period of the swing corresponds to a step length and period of the walk, respectively. Pronation/supination of the wrist joint of his/her right arm corresponds to a walk direction. The cooperative control algorithm based on a cart-table model designs trajectories of each joint for stable walking pattern that satisfies the intention expressed by the wearer's hand motion and then the designed walking pattern is executed in realtime by the walking support system. As the first trial, a small humanoid robot ¿HRP-2m¿ is used for safety as a control target that will be a combination of a wearer and the walking support system in the final situation. Through some experiments we confirm that our proposed algorithm enables the humanoid robot to start and stop stable walk with variable step length in the desired walking direction according to operator's intentions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474 · cited 3×
“In our study, a wearable-type robot “Robot Suit HAL” (Hybrid Assistive Limb) [12] has been”
MethodSelf-citation
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“This can be implemented through selections made on a remote control [76,142], pushing a button or squeezing a lever [140,147], and the execution of a particular sequence of finger [148], eye [79] or limb movements made with the device [136].”
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Farris, R. J., Quintero, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163083 · Cited by 342
Powered exoskeletons for bipedal locomotion after spinal cord injury
Contreras-Vidal, J. L., A Bhagat, N., Brantley, J., Cruz-Garza, J. G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S. H., Zhu, F., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/031001 · Cited by 216
“Other gait intent detection systems based on eye gaze (Duvinage et al 2011) and hand movements (Hasegawa et al 2009), have also been developed.”
BackgroundFarris, R. J., Quintero, H. A., Murray, S. A., Ha, K. H., Hartigan, C., & Goldfarb, M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2268320 · Cited by 208
A Method for the Autonomous Control of Lower Limb Exoskeletons for Persons With Paraplegia
Quintero, H. A., Farris, R. J., & Goldfarb, M. (2012) · Journal of Medical Devices · doi:10.1115/1.4007181 · Cited by 97
Metadata
- Authors
- Hasegawa, Y., Jang, J., & Sankai, Y.
- Venue
- 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2009-10
- Pages
- 4481-4486
- OpenAlex
- W2136658045
- Cited by
- 43
- References
- 1
- FWCI
- 9.04
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.