Unified temporal and spatial calibration for multi-sensor systems
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
In order to increase accuracy and robustness in state estimation for robotics, a growing number of applications rely on data from multiple complementary sensors. For the best performance in sensor fusion, these different sensors must be spatially and temporally registered with respect to each other. To this end, a number of approaches have been developed to estimate these system parameters in a two stage process, first estimating the time offset and subsequently solving for the spatial transformation between sensors. In this work, we present on a novel framework for jointly estimating the temporal offset between measurements of different sensors and their spatial displacements with respect to each other. The approach is enabled by continuous-time batch estimation and extends previous work by seamlessly incorporating time offsets within the rigorous theoretical framework of maximum likelihood estimation. Experimental results for a camera to inertial measurement unit (IMU) calibration prove the ability of this framework to accurately estimate time offsets up to a fraction of the smallest measurement period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
(2006) · Optimal Control and Forecasting of Complex Dynamical Systems · doi:10.1142/9789812774248_0002 · Cited by 1,362
An Introduction to Splines for Use in Computer Graphics and Geometric Modeling
Bartels, R. H., Beatty, J. C., & Barsky, B. A. (1987) · Cumulative Index of Computer Aided Architectural Design · Cited by 1,144
Algorithm 887: CHOLMOD, Supernodal Sparse Cholesky Factorization and Update/Downdate
Chen, Y., Davis, T. A., Hager, W. W., & Rajamanickam, S. (2008) · ACM Transactions on Mathematical Software · doi:10.1145/1391989.1391995 · Cited by 751
Digital Elevation Model Technologies and Applications : The Dem Users Manual
Maune, D. F. (2019) · Cited by 628
Network Time Protocol Version 4: Protocol and Algorithms Specification
Mills, D., Burbank, J., & Kasch, W. (2010) · doi:10.17487/rfc5905 · Cited by 577
Visual-Inertial Sensor Fusion: Localization, Mapping and Sensor-to-Sensor Self-calibration
Kelly, J., & Sukhatme, G. S. (2011) · The International Journal of Robotics Research · doi:10.1177/0278364910382802 · Cited by 536
Mirzaei, F. M., & Roumeliotis, S. I. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2004486 · Cited by 442
Estimation and removal of clock skew from network delay measurements
Moon, S. B., Skelly, P., & Towsley, D. (1999) · IEEE Conference on Computer Communications (INFOCOM) · doi:10.1109/infcom.1999.749287 · Cited by 428
R., J., & de Boor, C. (1980) · Mathematics of Computation · doi:10.2307/2006241 · Cited by 349
Continuous-time batch estimation using temporal basis functions
Furgale, P., Barfoot, T. D., & Sibley, G. (2012) · 2012 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2012.6225005 · Cited by 259
Self-citationRelative Pose Calibration Between Visual and Inertial Sensors
Lobo, J., & Dias, J. M. M. (2007) · The International Journal of Robotics Research · doi:10.1177/0278364907079276 · Cited by 250
A General Framework for Temporal Calibration of Multiple Proprioceptive and Exteroceptive Sensors
Kelly, J. W., & Sukhatme, G. S. (2013) · Springer tracts in advanced robotics · doi:10.1007/978-3-642-28572-1_14 · Cited by 81
Spatio-temporal initialization for IMU to camera registration
Mair, E., Fleps-Dezasse, M., Suppa, M., & Burschka, D. (2011) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2011.6181345 · Cited by 71
Optimization based IMU camera calibration
Fleps-Dezasse, M., Mair, E., Ruepp, O., Suppa, M., & Burschka, D. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6095067 · Cited by 62
Algorithm 888: Spherical Harmonic Transform Algorithms
Drake, J. B., Worley, P. H., & D'Azevedo, E. F. (2008) · ACM Transactions on Mathematical Software · doi:10.1145/1391989.1404581 · Cited by 51
TICSync: Knowing when things happened
Harrison, A., & Newman, P. M. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5980112 · Cited by 46
Camera-Inertial Sensor modelling and alignment for Visual Navigation
Alves, J. G., Lobo, J., & Dias, J. M. M. (2003) · Cited by 39
(1986)
Research works printed but not linked: 3
- 1998, IEEE aerospace and electronic systems society. Gyro and accelerometer panel and institute of electrical and electronics engineers, IEEE Standard Specification Format Guide and Test Procedure for Single-Axis Interferometric Fiber Optic Gyros
- mirzaei, 2007, IMU-Camera Calibration Bundle Adjustment Implementation
- chen, 1999, IEEE standard specification format guide and test procedure for linear, Single-Axis Nongyroscopic Accelerometers Ser IEEE (Std ) IEEE
Cited by
The EuRoC micro aerial vehicle datasets
Burri, M., Nikolic, J., Gohl, P., Schneider, T., Rehder, J., Omari, S., Achtelik, M. W., & Siegwart, R. (2016) · The International Journal of Robotics Research · doi:10.1177/0278364915620033 · Cited by 2,066
Self-citationKeyframe-based visual–inertial odometry using nonlinear optimization
Leutenegger, S., Lynen, S., Bosse, M., Siegwart, R., & Furgale, P. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914554813 · Cited by 1,723
Self-citationOn-Manifold Preintegration for Real-Time Visual--Inertial Odometry
Forster, C., Carlone, L., Dellaert, F., & Scaramuzza, D. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2597321 · Cited by 1,502
“1We calibrate the IMU-camera delay using the Kalibr toolbox [59].”
MethodSVO: Semidirect Visual Odometry for Monocular and Multicamera Systems
Forster, C., Zhang, Z., Gassner, M., Werlberger, M., & Scaramuzza, D. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2623335 · Cited by 922
Visual-Inertial Monocular SLAM With Map Reuse
Mur-Artal, R., & Tardos, J. D. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2653359 · Cited by 795
Metadata
- Authors
- Furgale, P., Rehder, J., & Siegwart, R.
- Venue
- 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2013-11
- Pages
- 1280-1286
- OpenAlex
- W1998058414
- Cited by
- 807
- References
- 19
- FWCI
- 30.09
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.