Automatic Heart Isolation for CT Coronary Visualization Using Graph-Cuts
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We describe a means to automatically and efficiently isolate the outer surface of the entire heart in computer tomography (CT) cardiac scans. Isolating the entire heart allows the coronary vessels on the surface of the heart to be easily visualized despite the proximity of surrounding organs such as the ribs and pulmonary blood vessels. Numerous techniques have been described for segmenting the left ventricle of the heart in images from various types of medical scanners but rarely has the entire heart been segmented. We make use of graph-cuts to do the segmentation and introduce a novel means of initiating and constraining the graph-cut technique for heart isolation. The technique has been tested on 70 patient data sets. Results are compares with hand labeled results
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interactive graph cuts for optimal boundary & region segmentation of objects in N-D images
Boykov, Y. Y., & Jolly, M.-P. (2002) · Proceedings Eighth IEEE International Conference on Computer Vision. ICCV 2001 · doi:10.1109/iccv.2001.937505 · Cited by 3,674
Self-citationExact Maximum A Posteriori Estimation for Binary Images
Greig, D. M., Porteous, B. T., & Seheult, A. H. (1989) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1989.tb01764.x · Cited by 1,055
Cited by
Graph Cuts and Efficient N-D Image Segmentation
Boykov, Y., & Funka-Lea, G. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-006-7934-5 · Cited by 1,910
“For example, incorporating flux can improve edge alignment (Vasilevskiy and Siddiqi, 2002; Kimmel and Bruckstein, 2003; Kolmogorov and Boykov, 2005; Funka-Lea et al., 2006) and greatly helps to segment thin objects.”
BackgroundSelf-citationA survey of graph theoretical approaches to image segmentation
Peng, B., Zhang, L., & Zhang, D. (2013) · Pattern Recognition · doi:10.1016/j.patcog.2012.09.015 · Cited by 390
Wolterink, J. M., Leiner, T., de Vos, B. D., van Hamersvelt, R. W., Viergever, M. A., & Išgum, I. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.04.004 · Cited by 321
Star Shape Prior for Graph-Cut Image Segmentation
Veksler, O. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-88690-7_34 · Cited by 287
Challenges and Methodologies of Fully Automatic Whole Heart Segmentation: A Review
Zhuang, X. (2013) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.4.3.371 · Cited by 162
“This is in contrast with many other cardiac segmentation works in the literature, which focus solely on the ventricles and/or left ventricle myocardium [25–44], or isolation of the whole heart volume [45–47].”
Result
Metadata
- Authors
- Funka-Lea, G., Boykov, Y., Florin, C., Jolly, M.-P., Moreau-Gobard, R., Ramaraj, R., & Rinck, D.
- Venue
- 3rd IEEE International Symposium on Biomedical Imaging: Macro to Nano, 2006.
- Publisher
- IEEE
- Published
- 2006-05-25
- Pages
- 614-617
- OpenAlex
- W2137624270
- Cited by
- 80
- References
- 2
- FWCI
- 3.68
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Heart Isolation for CT Coronary Visualization Using Graph-Cuts. https://app.cochat.ai/papers/10.1109/isbi.2006.1624991
- The paper
- Funka-Lea, G., Boykov, Y., Florin, C., Jolly, M.-P., Moreau-Gobard, R., Ramaraj, R., & Rinck, D. (2006). Automatic Heart Isolation for CT Coronary Visualization Using Graph-Cuts. 3rd IEEE International Symposium on Biomedical Imaging: Macro to Nano, 2006. https://doi.org/10.1109/isbi.2006.1624991
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.