Practical parallel imaging compressed sensing MRI: Summary of two years of experience in accelerating body MRI of pediatric patients
Open accessAbstract
For the last two years1, we have been experimenting with applying compressed sensing parallel imaging for body imaging of pediatric patients. It is a joint-effort by teams from UC Berkeley, Stanford University and GE Healthcare. This paper aims to summarize our experience so far. We describe our acquisition approach: 3D spoiled-gradient-echo with poisson-disc random undersampling of the phase encodes. Our reconstruction approach: ℓ1-SPIRiT, an iterative autocalibrating parallel imaging reconstruction that enforces both data consistency and joint-sparsity in the wavelet domain. Our implementation: an on-line parallelized implementation of ℓ1-SPIRiT on multi-core CPU and General Purpose Graphics Processors (GPGPU) that achieves sub-minute 3D reconstructions with 8-channels. Clinical results showing higher quality reconstruction and better diagnostic confidence than parallel imaging alone at accelerations on the order of number of coils.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Self-citation
Cited by
Medical image processing on the GPU – Past, present and future
Eklund, A., Dufort, P., Forsberg, D., & LaConte, S. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.008 · Cited by 397
Murphy, M., Alley, M., Demmel, J., Keutzer, K., Vasanawala, S., & Lustig, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2188039 · Cited by 313
Self-citationCompressed sensing for body MRI
Feng, L., Benkert, T., Block, K. T., Sodickson, D. K., Otazo, R., & Chandarana, H. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25547 · Cited by 306
Coil compression for accelerated imaging with Cartesian sampling
Zhang, T., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24267 · Cited by 273
Self-citationA Review of Sparse Recovery Algorithms
Crespo Marques, E., Maciel, N., Naviner, L., Cai, H., & Yang, J. (2019) · IEEE Access · doi:10.1109/access.2018.2886471 · Cited by 268
Metadata
- Authors
- Vasanawala, S., Murphy, M., Alley, M., Lai, P., Keutzer, K., Pauly, J., & Lustig, M.
- Venue
- 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro
- Publisher
- IEEE
- Published
- 2011-03
- Volume
- 2011
- Pages
- 1039-1043
- OpenAlex
- W2130299261
- Cited by
- 172
- References
- 1
- FWCI
- 26.97
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Practical parallel imaging compressed sensing MRI: Summary of two years of experience in accelerating body MRI of pediatric patients. https://app.cochat.ai/papers/10.1109/isbi.2011.5872579
- The paper
- Vasanawala, S., Murphy, M., Alley, M., Lai, P., Keutzer, K., Pauly, J., & Lustig, M. (2011). Practical parallel imaging compressed sensing MRI: Summary of two years of experience in accelerating body MRI of pediatric patients. 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro. https://doi.org/10.1109/isbi.2011.5872579
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.