The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Diagnostic classification of lung nodules using 3D neural networks
Open accessAbstract
Lung cancer is the leading cause of cancer-related death worldwide. Early diagnosis of pulmonary nodules in Computed Tomography (CT) chest scans provides an opportunity for designing effective treatment and making financial and care plans. In this paper, we consider the problem of diagnostic classification between benign and malignant lung nodules in CT images, which aims to learn a direct mapping from 3D images to class labels. To achieve this goal, four two-pathway Convolutional Neural Networks (CNN) are proposed, including a basic 3D CNN, a novel multi-output network, a 3D DenseNet, and an augmented 3D DenseNet with multi-outputs. These four networks are evaluated on the public LIDC-IDRI dataset and outperform most existing methods. In particular, the 3D multi-output DenseNet (MoDenseNet) achieves the state-of-the-art classification accuracy on the task of end-to-end lung nodule diagnosis. In addition, the networks pretrained on the LIDC-IDRI dataset can be further extended to handle smaller datasets using transfer learning. This is demonstrated on our dataset with encouraging prediction accuracy in lung nodule classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
The National Lung Screening Trial Research Team (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102873 · Cited by 11,064
Armato, S. G., McLennan, G., Bidaut, L., McNitt‐Gray, M. F., Meyer, C. R., Reeves, A. P., Zhao, B., Aberle, D. R., Henschke, C. I., Hoffman, E. A., et al. (2011) · Medical Physics · doi:10.1118/1.3528204 · Cited by 2,887
Cited by
A Review of Deep Learning on Medical Image Analysis
Wang, J., Zhu, H., Wang, S.-H., & Zhang, Y.-D. (2021) · Mobile Networks and Applications · doi:10.1007/s11036-020-01672-7 · Cited by 303
Going Deep in Medical Image Analysis: Concepts, Methods, Challenges, and Future Directions
Altaf, F., Islam, S. M. S., Akhtar, N., & Janjua, N. K. (2019) · IEEE Access · doi:10.1109/access.2019.2929365 · Cited by 286
Quanyang, W., Yao, H., Sicong, W., Linlin, Q., Zewei, Z., Donghui, H., Hongjia, L., & Shijun, Z. (2024) · Cancer Medicine · doi:10.1002/cam4.7140 · Cited by 111
Kumar, D., Sankar, V., Clausi, D., Taylor, G. W., & Wong, A. (2019) · IEEE Access · doi:10.1109/access.2019.2945524 · Cited by 26
Metadata
- Authors
- Dey, R., Lu, Z., & Hong, Y.
- Venue
- 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018)
- Publisher
- IEEE
- Published
- 2018-04
- Pages
- 774-778
- OpenAlex
- W2794187429
- Cited by
- 166
- References
- 2
- FWCI
- 9.78
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic classification of lung nodules using 3D neural networks. https://app.cochat.ai/papers/10.1109/isbi.2018.8363687
- The paper
- Dey, R., Lu, Z., & Hong, Y. (2018). Diagnostic classification of lung nodules using 3D neural networks. 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018). https://doi.org/10.1109/isbi.2018.8363687
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.