The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cryo-CARE: Content-Aware Image Restoration for Cryo-Transmission Electron Microscopy Data
Abstract
Multiple approaches to use deep learning for image restoration have recently been proposed. Training such approaches requires well registered pairs of high and low quality images. While this is easily achievable for many imaging modalities, e.g. fluorescence light microscopy, for others it is not. Cryo-transmission electron microscopy (cryo-TEM) could profoundly benefit from improved denoising methods, unfortunately it is one of the latter. Here we show how recent advances in network training for image restoration tasks, i.e. denoising, can be applied to cryo-TEM data. We describe our proposed method and show how it can be applied to single cryo-TEM projections and whole cryo-tomographic image volumes. Our proposed restoration method dramatically increases contrast in cryo-TEM images, which improves the interpretability of the acquired data. Furthermore we show that automated downstream processing on restored image data, demonstrated on a dense segmentation task, leads to improved results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Cited by
Noise2Void - Learning Denoising From Single Noisy Images
Krull, A., Buchholz, T.-O., & Jug, F. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00223 · Cited by 1,366
Self-citationApplications, promises, and pitfalls of deep learning for fluorescence image reconstruction
Belthangady, C., & Royer, L. A. (2019) · Nature Methods · doi:10.1038/s41592-019-0458-z · Cited by 510
Multi-particle cryo-EM refinement with M visualizes ribosome-antibiotic complex at 3.5 Å in cells
Tegunov, D., Xue, L., Dienemann, C., Cramer, P., & Mahamid, J. (2021) · Nature Methods · doi:10.1038/s41592-020-01054-7 · Cited by 509
Software tools for automated transmission electron microscopy
Schorb, M., Haberbosch, I., Hagen, W. J. H., Schwab, Y., & Mastronarde, D. N. (2019) · Nature Methods · doi:10.1038/s41592-019-0396-9 · Cited by 504
The promise and the challenges of cryo‐electron tomography
Turk, M., & Baumeister, W. (2020) · FEBS Letters · doi:10.1002/1873-3468.13948 · Cited by 333
Metadata
- Authors
- Buchholz, T.-O., Jordan, M., Pigino, G., & Jug, F.
- Venue
- 2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019)
- Publisher
- IEEE
- Published
- 2019-04
- Pages
- 502-506
- OpenAlex
- W2897492435
- Cited by
- 183
- References
- 1
- FWCI
- 49.53
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cryo-CARE: Content-Aware Image Restoration for Cryo-Transmission Electron Microscopy Data. https://app.cochat.ai/papers/10.1109/isbi.2019.8759519
- The paper
- Buchholz, T.-O., Jordan, M., Pigino, G., & Jug, F. (2019). Cryo-CARE: Content-Aware Image Restoration for Cryo-Transmission Electron Microscopy Data. 2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019). https://doi.org/10.1109/isbi.2019.8759519
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.