Cited by 0Optimal Power Flow DistributionPower Quality and HarmonicsMicrogrid Control and Optimization

Voltage Issue Alleviation in Low Voltage System with High PV and EV Penetration using Distribution Transformer with On-Load Tap Changer (OLTC)

Prachuab, Piyapong, Sunthonkarun, Supatra·2024·2024 IEEE International Smart Cities Conference (ISC2)

Abstract

As the use of solar photovoltaic (PV) systems and electric vehicles (EVs) becomes more prevalent, maintaining stable voltage levels in distribution systems has become a challenge. In urban areas, green housing estates equipped with large amounts of rooftop solar panels can create daytime voltage spikes due to reverse power flow, while EV charging behavior in the evenings can result in significant load and voltage drops. These fluctuations can push voltage beyond acceptable service levels. To address this challenge, the Metropolitan Electricity Authority (MEA) in Thailand is exploring solutions and has discovered that a distribution transformer with on-load tap changer (OLTC) can alleviate the voltage issue. The OLTC can dynamically adjust the transformer's ratio to maintain voltage stability at the secondary side. This paper analyzes two OLTC operation modes: constant secondary voltage and active power-dependent voltage adjustment. The study compares these modes with a non-OLTC transformer through simulations, and the results indicate that the OLTC, particularly when operated in active power-dependent mode with optimized settings, can effectively maintain voltage levels within the service boundaries.

Integrity signals

Registry

Crossref · 10.1109/isc260477.2024.11004194

Cites

0 of 5 references verified0 citation errors · 5 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Cites

  • Ministry of Energy, Thailand

    (2020) · Alternative Energy Development Plan

    Unresolved
  • My Energy, MEA

    (2024)

    Unresolved
  • MEA 100 charging points

    (2024)

    Unresolved
  • IoT with On-load tap changer transformer in LV distribution network

    Udomparichatr (2020)

    Unresolved
  • Untitled work

    (n.d.) · Voltage Regulator ECOTAP® VPD® Control Pro Operating Instructions

    Unresolved

Flagged first, then by citations

5 of the 5 references couldn’t be matched to a known paper.

Authors
Prachuab, P., & Sunthonkarun, S.
Affiliations
Metropolitan Electricity Authority,Power System Planning and Smart Grid Department,Bangkok,Thailand
Venue
2024 IEEE International Smart Cities Conference (ISC2)
Publisher
IEEE
Published
2024-10-29
Pages
1-6
OpenAlex
W4410583931
Cited by
0
References
5
FWCI
0.00
Type
conference paper
Language
en
Open access
closed
Locations
IEEE International Smart Cities Conference (ISC2) (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
Keywords
on-load tap changer, distribution transformers, voltage regulation, photovoltaic penetration, electric vehicle charging, reverse power flow, voltage fluctuation, low-voltage distribution networks, rooftop solar

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review