Cited by 11Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignRadio Frequency Integrated Circuit Design

An Integrated Bidirectional Multi-Channel Opto-Electro Arbitrary Waveform Stimulator for Treating Motor Neurone Disease

Open access
Jiang, Dai, Wu, Yu, Almarri, Noora, Habibollahi, Maryam, Liu, Fangqi, Bryson, J. Barney, Greensmith, Linda, Demosthenous, Andreas·2021·2021 IEEE International Symposium on Circuits and Systems (ISCAS)

Abstract

This paper presents a prototype integrated bidirectional stimulator ASIC capable of mixed opto-electro stimulation and electrophysiological signal recording. The development is part of the research into a fully implantable device for treating motor neurone disease using optogenetics and stem cell technology. The ASIC consists of 4 stimulator units, each featuring 16-channel optical and electrical stimulation using arbitrary current waveforms with an amplitude up to 16 mA and a frequency from 1.5 Hz to 50 kHz, and a recording front-end with a programmable bandwidth of 1 Hz to 4 kHz, and a programmable amplifier gain up to 74 dB. The ASIC was implemented in a 0.18μm CMOS technology. Simulated performance in stimulation and recording is presented.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iscas51556.2021.9401220

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Biphasic delivery of stimulus pulses is commonly achieved using a set of switches placed in a H-bridge structure.

    “Biphasic delivery of stimulus pulses is commonly achieved using a set of switches placed in a H-bridge structure. Each electrode operates as either a cathode or an anode from a single supply current, maximising flexibility and limiting the reliance on storage capacitors [57], [134].”

    From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [134]

    The Current Driver section (page unavailable) says the paper's H-bridge forms biphasic current pulses, supporting the described approach. It does not establish that this arrangement is commonly used across stimulators. (LLM, conf=0.82)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 18 · Cited by 11

Authors
Jiang, D., Wu, Y., Almarri, N., Habibollahi, M., Liu, F., Bryson, J. B., Greensmith, L., & Demosthenous, A.
Affiliations
  • University College London (GB)
  • UCL Queen Square Institute of Neurology (GB)
Venue
2021 IEEE International Symposium on Circuits and Systems (ISCAS)
Publisher
IEEE
Published
2021-05
Pages
1-4
ISSN
0271-4302 (ISSN-L)
OpenAlex
W3159523312
Cited by
11
References
18
Citations by year
2024: 2 · 2023: 3 · 2022: 3 · 2021: 3
FWCI
11.06
Type
conference paper
Language
en
Open access
Locations
  • IEEE International Symposium on Circuits and Systems proceedings (publishedVersion)
  • UCL Discovery (University College London) (submittedVersion)
Funders
Medical Research Council
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
optogenetics, motor neuron disease, multichannel stimulation, implantable neurostimulator, ASIC, electrophysiological recording, stem cell therapy, 0.18 μm CMOS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review