An Integrated Bidirectional Multi-Channel Opto-Electro Arbitrary Waveform Stimulator for Treating Motor Neurone Disease
Open accessAbstract
This paper presents a prototype integrated bidirectional stimulator ASIC capable of mixed opto-electro stimulation and electrophysiological signal recording. The development is part of the research into a fully implantable device for treating motor neurone disease using optogenetics and stem cell technology. The ASIC consists of 4 stimulator units, each featuring 16-channel optical and electrical stimulation using arbitrary current waveforms with an amplitude up to 16 mA and a frequency from 1.5 Hz to 50 kHz, and a recording front-end with a programmable bandwidth of 1 Hz to 4 kHz, and a programmable amplifier gain up to 74 dB. The ASIC was implemented in a 0.18μm CMOS technology. Simulated performance in stimulation and recording is presented.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Biphasic delivery of stimulus pulses is commonly achieved using a set of switches placed in a H-bridge structure.
“Biphasic delivery of stimulus pulses is commonly achieved using a set of switches placed in a H-bridge structure. Each electrode operates as either a cathode or an anode from a single supply current, maximising flexibility and limiting the reliance on storage capacitors [57], [134].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [134]
The Current Driver section (page unavailable) says the paper's H-bridge forms biphasic current pulses, supporting the described approach. It does not establish that this arrangement is commonly used across stimulators. (LLM, conf=0.82)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 18 · Cited by 11
- Authors
- Jiang, D., Wu, Y., Almarri, N., Habibollahi, M., Liu, F., Bryson, J. B., Greensmith, L., & Demosthenous, A.
- Affiliations
- University College London (GB)
- UCL Queen Square Institute of Neurology (GB)
- ORCID
- Venue
- 2021 IEEE International Symposium on Circuits and Systems (ISCAS)
- Publisher
- IEEE
- Published
- 2021-05
- Pages
- 1-4
- ISSN
- 0271-4302 (ISSN-L)
- OpenAlex
- W3159523312
- Cited by
- 11
- References
- 18
- Citations by year
- 2024: 2 · 2023: 3 · 2022: 3 · 2021: 3
- FWCI
- 11.06
- Type
- conference paper
- Language
- en
- Open access
- green
- discovery.ucl.ac.uk
- Licence
- Locations
- IEEE International Symposium on Circuits and Systems proceedings (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Medical Research Council
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- optogenetics, motor neuron disease, multichannel stimulation, implantable neurostimulator, ASIC, electrophysiological recording, stem cell therapy, 0.18 μm CMOS
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review