Modular multilevel inverter with maximum power point tracking for grid connected photovoltaic application
The DOI matches its Crossref record.
Abstract
A single-phase modular multilevel inverter based photovoltaic system for grid connection is proposed. This photovoltaic system utilizes two conversion stages; a boost converter for tracking the maximum power point and a modular multilevel inverter used as an interfacing unit. The maximum power point tracking is achieved with a fuzzy logic controller, and the modular multilevel inverter regulates the dc link voltage and synchronizes the grid voltage and current in order to achieve unity power factor operation. The proposed system provides high dynamic performance and power quality injected into the grid. The validity of the proposed system is confirmed by simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Circuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
“Other interesting applications of MMC are the high-voltage dc–dc conversion to form a dc-micro grid [51], [226]–[228] and grid integration of photovoltaic (PV) systems [229], [230], wind energy conversion systems [231], and battery energy storage systems [232].”
Mei, J., Xiao, B., Shen, K., Tolbert, L. M., & Zheng, J. Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2243758 · Cited by 319
Control of arm capacitor voltages in modular multilevel converters
Lizana, R., Perez, M. A., Bernet, S., Espinoza, J. R., & Rodriguez, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2426183 · Cited by 70
“This situation can take place, for example, when the MMC is used in photovoltaic applications [21]–[23], where the panels are directly connected to each cell and the capacitor voltage must change in order to achieve the maximum power point tracking [24], or in battery energy storage systems [25], [26].”
BackgroundDesign and implementation of the control of an MMC-based solid state transformer
Lopez, M., Rodriguez, A., Blanco, E., Saeed, M., Martinez, A., & Briz, F. (2015) · 2015 IEEE 13th International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin.2015.7281970 · Cited by 24
Metadata
- Authors
- Alajmi, B. N., Ahmed, K. H., Adam, G. P., Finney, S. J., & Williams, B. W.
- Venue
- 2011 IEEE International Symposium on Industrial Electronics
- Publisher
- IEEE
- Published
- 2011-06
- Pages
- 2057-2062
- OpenAlex
- W2140402652
- Cited by
- 33
- References
- 0
- FWCI
- 3.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.