CoChat

Improving cybersecurity for Industrial Control Systems

Graham, James, Hieb, Jeffrey, Naber, John · 2016 · 2016 IEEE 25th International Symposium on Industrial Electronics (ISIE)
Cited by 43

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The vulnerability of industrial control systems (ICS) to electronic intrusion and malware has recently been well documented in both the technical and popular press. Despite significant attention and much progress over the past 15 years, threats continue to evolve about as fast as preventive solutions. This paper reviews the root causes of ICS cybersecurity vulnerabilities, looks at some common defensive measures and then discusses a new approach to ICS field device cybersecurity, the security preprocessor. This device offers advanced communications security and role-based access control for legacy ICS installations, and utilizes a verified microkernel, with proven security properties.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/isie.2016.7744960

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 9

  1. langner, 2013, To Kill a Centrifuge: A Technical Analysis of What Stuxnet's Creators Tried to Achieve, The Langer Group
  2. weiss, 2010, Protecting Industrial Control Systems from Electronic Attack
  3. graham, 2014, Device Method and System for Processing Communications for Secure Operation of Industrial Control System
  4. radvanovsky, 2015, Project SHINE: What We Discovered and Why You Should Care, 10th Sans ICS Security Summit
  5. adams, 2011, A Water System Simulation for Testing Security Enhancements to SCADA Field Devices, Proc 24th Intl Conference on Computer Applications in Industry and Engineering, 305
  6. cowan, 0, Energy Sector Tops List of US Industries Under Attack, Says DHS Report, m2m now news
  7. 10.1145/2560537 · DOI · Paper page
  8. graham, 2013, Security Hardened Enhanced Network Device and Method for Secure Operation of Same
  9. brocklehurst, 2014, DHS Confirms US Public Utility's Control System Was Hacked, The State of Security Newsletter

Cited by

See all 43

Metadata

Authors
Graham, J., Hieb, J., & Naber, J.
Venue
2016 IEEE 25th International Symposium on Industrial Electronics (ISIE)
Publisher
IEEE
Published
2016-06
Pages
618-623
OpenAlex
W2558796881
Cited by
43
References
1
FWCI
7.99
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving cybersecurity for Industrial Control Systems. https://app.cochat.ai/papers/10.1109/isie.2016.7744960
The paper
Graham, J., Hieb, J., & Naber, J. (2016). Improving cybersecurity for Industrial Control Systems. 2016 IEEE 25th International Symposium on Industrial Electronics (ISIE). https://doi.org/10.1109/isie.2016.7744960

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.