Automated seizure detection in scalp EEG using multiple wavelet scales
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The proposed research work designs a detector algorithm for automatic detection of epileptic seizures. In this work a wavelet based feature extraction technique has been adopted. Epochs of EEG are decomposed using discrete wavelet transform (DWT) up to 5 level of wavelet decomposition. Relative values of energy and a normalized coefficient of variation (NCOV) based measure, (σ2/μa) are computed on the wavelet coefficients acquired in the frequency range of 0-32 Hz from both seizure and non-seizure segments. The performance of NCOV over the traditionally used coefficient of variation, COV (σ2/μ2) was studied. The feature NCOV yielded better performance than the commonly used COV, σ2/μ2. The algorithm was evaluated on 5 subjects from CHB-MIT scalp EEG database.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EEG signal classification using wavelet feature extraction and a mixture of expert model.
SUBASI, A. (2007) · Expert Systems with Applications · doi:10.1016/j.eswa.2006.02.005 · Cited by 1,182
Cited by
An automated system for epilepsy detection using EEG brain signals based on deep learning approach
Ullah, I., Hussain, M., Qazi, E.-U.-H., & Aboalsamh, H. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.04.021 · Cited by 622
A Multivariate Approach for Patient-Specific EEG Seizure Detection Using Empirical Wavelet Transform
Bhattacharyya, A., & Pachori, R. B. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2650259 · Cited by 419
EEG seizure detection and prediction algorithms: a survey
Alotaiby, T. N., Alshebeili, S. A., Alshawi, T., Ahmad, I., & Abd El-Samie, F. E. (2014) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/1687-6180-2014-183 · Cited by 292
Li, Y., Liu, Y., Cui, W.-G., Guo, Y.-Z., Huang, H., & Hu, Z.-Y. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2973434 · Cited by 285
Hussein, R., Palangi, H., Ward, R. K., & Wang, Z. J. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.10.010 · Cited by 263
Deep Multi-View Feature Learning for EEG-Based Epileptic Seizure Detection
Tian, X., Deng, Z., Ying, W., Choi, K.-S., Wu, D., Qin, B., Wang, J., Shen, H., & Wang, S. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2940485 · Cited by 195
Liang, W., Pei, H., Cai, Q., & Wang, Y. (2020) · Neurocomputing · doi:10.1016/j.neucom.2018.10.108 · Cited by 100
Epilepsy Classification for Mining Deeper Relationships between EEG Channels based on GCN
Chen, X., Zheng, Y., Niu, Y., & Li, C. (2020) · 2020 International Conference on Computer Vision, Image and Deep Learning (CVIDL) · doi:10.1109/cvidl51233.2020.00050 · Cited by 34
Metadata
- Authors
- Khan, Y. U., Rafiuddin, N., & Farooq, O.
- Venue
- 2012 IEEE International Conference on Signal Processing, Computing and Control
- Publisher
- IEEE
- Published
- 2012-03
- Pages
- 1-5
- OpenAlex
- W1998828740
- Cited by
- 130
- References
- 1
- FWCI
- 6.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.