The DOI matches its Crossref record.
A wireless single-chip telemetry-powered neural stimulation system
Abstract
This fully-integrated single-chip inductively-powered microsystem is capable of providing milliwatts for wireless operation. The chip is for an implantable multichannel neural microstimulator, but can be also used in other emerging applications for sensing and actuation microsystems. The fully-integrated neuromuscular electrical stimulation system (FINESS) is for use in peripheral nerve stimulation and will be attached to cuff electrodes that interface to the nerve for delivery of a bi-phasic stimulation pulse. FINESS receives all power and data through inductive coupling with an integrated, on-chip coil.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Inductive power transfer introduces bioengineering challenges due to Specific Absorption Rate limits and minimal size capacity for device implantation.
“However, inductive power transfer introduces numerous bioengineering challenges due to Specific Absorption Rate (SAR) limits and minimal size capacity for device implantation.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [16]
Citations
Cites
No references could be resolved yet.
Cited by
Sorted by citations
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system
Abiri, P., Abiri, A., Packard, R. R. S., Ding, Y., Yousefi, A., Ma, J., Bersohn, M., Nguyen, K.-L., Markovic, D., Moloudi, S., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06493-5 · Cited by 68
Metadata
- Authors
- Von Arx, J. A., & Najafi, K.
- Venue
- 1999 IEEE International Solid-State Circuits Conference. Digest of Technical Papers. ISSCC. First Edition (Cat. No.99CH36278)
- Publisher
- IEEE
- Published
- 2003-01-20
- Pages
- 214-215
- ISSN
- 0193-6530 (ISSN-L)
- OpenAlex
- W1520870552
- Cited by
- 74
- References
- 0
- Citations by year
- 2022: 1 · 2021: 1 · 2020: 3 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 2 · 2012: 4
- FWCI
- 13.83
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- neurostimulation, neuromuscular electrical stimulation, peripheral nerve stimulation, inductive power transfer, wireless telemetry, cuff electrodes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review