Cited by 115Wireless Power Transfer SystemsWireless Body Area NetworksRadio Frequency Integrated Circuit Design

Fully Integrated On-Chip Coil in 0.13 <formula formulatype="inline"><tex Notation="TeX">$\mu {\rm m}$</tex></formula> CMOS for Wireless Power Transfer Through Biological Media

Zargham, Meysam, Gulak, P. Glenn·2015·IEEE Transactions on Biomedical Circuits and Systems

Abstract

Delivering milliwatts of wireless power at centimeter distances is advantageous to many existing and emerging biomedical applications. It is highly desirable to fully integrate the receiver on a single chip in standard CMOS with no additional post-processing steps or external components. This paper presents a 2 × 2.18 mm(2) on-chip wireless power transfer (WPT) receiver (Rx) coil fabricated in 0.13 μm CMOS. The WPT system utilizes a 14.5 × 14.5 mm(2) transmitter (Tx) coil that is fabricated on a standard FR4 substrate. The on-chip power harvester demonstrates a peak WPT efficiency of -18.47 dB , -20.96 dB and -20.15 dB at 10 mm of separation through air, bovine muscle and 0.2 molar NaCl, respectively. The achieved efficiency enables the delivery of milliwatts of power to application circuits while staying below safe power density and electromagnetic (EM) exposure limits.

Integrity signals

Registry

Crossref · 10.1109/tbcas.2014.2328318

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Efforts have been reported to integrate LEDs for optogenetic stimulation and receiving elements for wireless power transfer on chip for mm-scale devices.

    “Other common off-chip components include light emitting diodes (LEDs) for optogenetic stimulation, and receiving elements for wireless power transfer, such as inductors, antennas, ultrasonic transducers. Efforts have been reported to integrate all of these on chip for mm-scale devices (Zargham and Glenn Gulak 2015; Gurun et al. 2014).”

The citation lists haven’t been fetched yet

References 53 · Cited by 115

Authors
Zargham, M., & Gulak, P. G.
Affiliations
University of Toronto (CA)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2015-04
Volume
9
Issue
2
Pages
259-271
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W1985670099
Cited by
115
References
53
Citations by year
2026: 2 · 2025: 4 · 2024: 5 · 2023: 11 · 2022: 4 · 2021: 13 · 2020: 13 · 2019: 18 · 2018: 13 · 2017: 15 · 2016: 11 · 2015: 6
FWCI
5.67
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
wireless power transfer, energy harvesting, biological media, bovine muscle, saline, electromagnetic exposure limits, 130 nm CMOS
MeSH terms
Animals, Cattle, Culture Media, Equipment Design, Models, Theoretical, Muscle, Skeletal, Lab-On-A-Chip Devices, Wireless Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review