The DOI matches its Crossref record.
A 128 × 128 CMOS bio-sensor array for extracellular recording of neural activity
Abstract
A CMOS sensor array for monitoring neural signals of living cells with 128 /spl times/ 128 pixels in a 1 mm/sup 2/ area is described. A standard 0.5 /spl mu/m, 5 V CMOS process extended by top electrodes covered by a relatively thin bio-compatible dielectric is used. Detection circuitry is based on a sensor-MOSFET mismatch-compensating current-mode technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
A 128 x 128 cmos biosensor array for extracellular recording of neural activity
Eversmann, B., Jenkner, M., Hofmann, F., Paulus, C., Brederlow, R., Holzapfl, B., Fromherz, P., Merz, M., Brenner, M., Schreiter, M., et al. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.819174 · Cited by 375
Self-citationFang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
A nanoelectrode array for obtaining intracellular recordings from thousands of connected neurons
Abbott, J., Ye, T., Krenek, K., Gertner, R. S., Ban, S., Kim, Y., Qin, L., Wu, W., Park, H., & Ham, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0455-7 · Cited by 272
CMOS nanoelectrode array for all-electrical intracellular electrophysiological imaging
Abbott, J., Ye, T., Qin, L., Jorgolli, M., Gertner, R. S., Ham, D., & Park, H. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.3 · Cited by 266
Metadata
- Authors
- Eversmann, B., Jenkner, M., Paulus, C., Hofmann, F., Brederlow, R., Holzapfl, B., Fromherz, P., Brenner, M., Schreiter, M., Gabl, R., Plehnert, K., Steinhauser, M., Eckstein, G., Schmitt-Landsiedel, D., & Thewes, R.
- Venue
- 2003 IEEE International Solid-State Circuits Conference, 2003. Digest of Technical Papers. ISSCC.
- Publisher
- IEEE
- Published
- 2003-12-22
- Volume
- 1
- Pages
- 222-489
- ISSN
- 0193-6530 (ISSN-L)
- OpenAlex
- W2174225487
- Cited by
- 212
- References
- 0
- FWCI
- 19.17
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 128 × 128 CMOS bio-sensor array for extracellular recording of neural activity. https://app.cochat.ai/papers/10.1109/isscc.2003.1234276
- The paper
- Eversmann, B., Jenkner, M., Paulus, C., Hofmann, F., Brederlow, R., Holzapfl, B., Fromherz, P., Brenner, M., Schreiter, M., Gabl, R., Plehnert, K., Steinhauser, M., Eckstein, G., Schmitt-Landsiedel, D., & Thewes, R. (2003). A 128 × 128 CMOS bio-sensor array for extracellular recording of neural activity. 2003 IEEE International Solid-State Circuits Conference, 2003. Digest of Technical Papers. ISSCC. https://doi.org/10.1109/isscc.2003.1234276
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.