Capacitively coupled arrays of multiplexed flexible silicon transistors for long-term cardiac electrophysiology
Open accessAbstract
Advanced capabilities in electrical recording are essential for the treatment of heart-rhythm diseases. The most advanced technologies use flexible integrated electronics; however, the penetration of biological fluids into the underlying electronics and any ensuing electrochemical reactions pose significant safety risks. Here, we show that an ultrathin, leakage-free, biocompatible dielectric layer can completely seal an underlying layer of flexible electronics while allowing for electrophysiological measurements through capacitive coupling between tissue and the electronics, and thus without the need for direct metal contact. The resulting current-leakage levels and operational lifetimes are, respectively, four orders of magnitude smaller and between two and three orders of magnitude longer than those of any other flexible-electronics technology. Systematic electrophysiological studies with normal, paced and arrhythmic conditions in Langendorff hearts highlight the capabilities of the capacitive-coupling approach. Our technology provides a realistic pathway towards the broad applicability of biocompatible, flexible electronic implants.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In vivo ECG recording equipment on the surface of the heart is subjected to dynamic movement, unlike static neural implants.
“Unlike static neural implants mentioned above, in vivo ECG recording equipment on the surface of the heart is subjected to dynamic movement.[375–378]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [376]
Wearable sweat sensors address the limitation of traditional sweat testing by enabling in situ sweat measurements with real-time feedback, creating potential for preventive care, timely diagnosis, and treatment.
“By taking advantage of flexible and hybrid electronics (13–17), wearable sweat sensors address this limitation by enabling in situ sweat measurements with real-time feedback, creating potential for preventive care, timely diagnosis, and treatment (18–34).”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [14]
The Abstract describes flexible electronic implants for cardiac electrophysiology, and the Discussion addresses cardiac mapping and potential arrhythmia diagnosis and treatment. Searches for sweat sensors, in situ sweat measurement, and traditional sweat testing found no passage addressing the attributed claim. (LLM, conf=0.77)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042 · see citing works
Someya, T., Kato, Y., Sekitani, T., Iba, S., Noguchi, Y., Murase, Y., Kawaguchi, H., & Sakurai, T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502392102 · Cited by 1,389 · see citing works
Untersuchungen am überlebenden Säugethierherzen
Langendorff, O. (1895) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf01812150 · Cited by 1,329 · see citing works
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274 · see citing works
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136 · see citing works
Self-citationTreatment of Atrial Fibrillation by the Ablation of Localized Sources
Narayan, S. M., Krummen, D. E., Shivkumar, K., Clopton, P., Rappel, W., & Miller, J. M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.05.022 · Cited by 1,118 · see citing works
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,069 · see citing works
Self-citationMulti-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991 · see citing works
Biocorrosion: towards understanding interactions between biofilms and metals
Beech, I. B., & Sunner, J. A. (2004) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.05.001 · Cited by 953 · see citing works
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938 · see citing works
Wu, W., Wen, X., & Wang, Z. L. (2013) · Science · doi:10.1126/science.1234855 · Cited by 931 · see citing works
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878 · see citing works
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen‐Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798 · see citing works
Kim, D., Lu, N., Ghaffari, R., Kim, Y., Lee, S. P., Xu, L., Wu, J. C., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 766 · see citing works
Self-citationXu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634 · see citing works
Self-citationStretchable Interconnects for Elastic Electronic Surfaces
Lacour, S. P., Jones, J., Wagner, S., Li, T., & Suo, Z. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.851502 · Cited by 621 · see citing works
Spiral waves of excitation underlie reentrant activity in isolated cardiac muscle.
Pertsov, A. M., Davidenko, J. M., Salomonsz, R., Baxter, W. T., & Jalife, J. (1993) · Circulation Research · doi:10.1161/01.res.72.3.631 · Cited by 612 · see citing works
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., Loeb, G. E., Berwald‐Netter, Y., & Okun, L. M. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580 · see citing works
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580 · see citing works
A Neuron-Silicon Junction: A Retzius Cell of the Leech on an Insulated-Gate Field-Effect Transistor
Fromherz, P., Offenhäusser, A., Vetter, T. R., & Weis, J. (1991) · Science · doi:10.1126/science.1925540 · Cited by 563 · see citing works
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560 · see citing works
Vegas, A. J., Veiseh, O., Doloff, J. C., Ma, M., Tam, H. H., Bratlie, K., Li, J., Bader, A. R., Langan, E., Olejnik, K., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3462 · Cited by 551 · see citing works
A Conformal, Bio-Interfaced Class of Silicon Electronics for Mapping Cardiac Electrophysiology
Viventi, J., Kim, D., Moss, J. D., Kim, Y., Blanco, J. A., Annetta, N. V., Hicks, A., Xiao, J., Huang, Y., Callans, D. J., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000738 · Cited by 419 · see citing works
Self-citationOnuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 417 · see citing works
Efimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390 · see citing works
Self-citationA 128 x 128 cmos biosensor array for extracellular recording of neural activity
Eversmann, B., Jenkner, M., Hofmann, F. B., Paulus, C., Brederlow, R., Holzapfl, B., Fromherz, P., Merz, M., Brenner, M., Schreiter, M., et al. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.819174 · Cited by 375 · see citing works
Integrated flexible chalcogenide glass photonic devices
Li, L., Lin, H., Qiao, S., Zou, Y., Danto, S., Richardson, K. A., Musgraves, J. D., Lu, N., & Hu, J. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.138 · Cited by 364 · see citing works
Duan, X., Li, Y., Rajan, N. K., Routenberg, D. A., Modis, Y., & Reed, M. A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.82 · Cited by 364 · see citing works
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358 · see citing works
Ward, W. K. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200504 · Cited by 328 · see citing works
Berdondini, L., Imfeld, K., Maccione, A., Tedesco, M., Neukom, S., Koudelka‐Hep, M., & Sergio Martinoia, A. (2009) · Lab on a Chip · doi:10.1039/b907394a · Cited by 320 · see citing works
Zeck, G., & Fromherz, P. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.181348698 · Cited by 290 · see citing works
Virtual Electrode–Induced Phase Singularity
Efimov, I. R., CHENG, Y. N., Wagoner, D. R. V., Mazgalev, T. N., & TCHOU, P. J. (1998) · Circulation Research · doi:10.1161/01.res.82.8.918 · Cited by 289 · see citing works
Self-citationCapacitive Epidermal Electronics for Electrically Safe, Long‐Term Electrophysiological Measurements
Jeong, J., Kim, M. K., Cheng, H., Yeo, W., Huang, X., Liu, Y., Zhang, Y., Huang, Y., & Rogers, J. A. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300334 · Cited by 288 · see citing works
Self-citationLiu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 272 · see citing works
Bakkum, D. J., Frey, U., Radivojević, M., Russell, T. L., Müller, J., Michele, F., Takahashi, H., & Hierlemann, A. R. (2013) · Nature Communications · doi:10.1038/ncomms3181 · Cited by 269 · see citing works
Electronic sensor and actuator webs for large-area complex geometry cardiac mapping and therapy
Kim, D., Ghaffari, R., Lu, N., Wang, S., Lee, S. P., Keum, H., D’Angelo, R., Klinker, L. E., Su, Y., Lü, C., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1205923109 · Cited by 240 · see citing works
Self-citationDEEP BRAIN STIMULATOR HARDWARE-RELATED INFECTIONS
Sillay, K. A., Larson, P., & Starr, P. A. (2008) · Neurosurgery · doi:10.1227/01.neu.0000316002.03765.33 · Cited by 226 · see citing works
A 128 × 128 CMOS bio-sensor array for extracellular recording of neural activity
Eversmann, B., Jenkner, M., Paulus, C., Hofmann, F. B., Brederlow, R., Holzapfl, B., Fromherz, P., Brenner, M., Schreiter, M., Gabl, R., et al. (2003) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2003.1234276 · Cited by 212 · see citing works
Experimental and Theoretical Analysis of Phase Singularity Dynamics in Cardiac Tissue
Bray, M., Lin, S., Aliev, R. R., et al. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00716.x · Cited by 143 · see citing works
Electrical recordings from rat cardiac muscle cells using field-effect transistors
Sprößler, C., Denyer, M. C. T., Britland, S. T., et al. (1999) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.60.2171 · Cited by 106 · see citing works
The Packaging of Implantable Integrated Sensors
Bowman, L., & MEINDL, J. D. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325807 · Cited by 103 · see citing works
Camelliti, P., Al‐Saud, S. A., Smolenski, R. T., Alayoubi, S., Bussek, A., Wettwer, E., Banner, N. R., Bowles, C. T., Yacoub, M. H., & Terracciano, C. M. (2011) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2011.06.018 · Cited by 86 · see citing works
Huys, R., Braeken, D., Jans, D., Stassen, A., Collaert, N., Wouters, J. M., Loo, J., Severi, S., Vleugels, F., Callewaert, G., et al. (2012) · Lab on a Chip · doi:10.1039/c2lc21037a · Cited by 79 · see citing works
Cardiovascular Collapse Caused by Electrocardiographically Silent 60-Hz Intracardiac Leakage Current
Swerdlow, C. D., Olson, W. H., O'Connor, M., Gallik, D. M., Malkin, R. A., & Laks, M. M. (1999) · Circulation · doi:10.1161/01.cir.99.19.2559 · Cited by 60 · see citing works
Su, Y., Li, S., Li, R., & Dağdeviren, C. (2015) · Applied Physics Letters · doi:10.1063/1.4927677 · Cited by 58 · see citing works
Combined Phase Singularity and Wavefront Analysis for Optical Maps of Ventricular Fibrillation
Rogers, J. M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820341 · Cited by 57 · see citing works
Self-citationNovel mapping techniques for cardiac electrophysiology
Friedman, P. A. (2002) · Heart · doi:10.1136/heart.87.6.575 · Cited by 55 · see citing works
Shi, Y., Rogers, J. A., Gao, C., et al. (2014) · Journal of Applied Mechanics · doi:10.1115/1.4028465 · Cited by 55 · see citing works
Self-citationFibrillation and defibrillation of the heart
Bossaert, L. L. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.2.203 · Cited by 40 · see citing works
Recommendations for Safe Current Limits for Electrocardiographs
Laks, M. M., ARZBAECHER, R. C., Bailey, J. J., Geselowitz, D. B., & Berson, A. S. (1996) · Circulation · doi:10.1161/01.cir.93.4.837 · Cited by 37 · see citing works
Noninvasive Mapping to Guide Atrial Fibrillation Ablation
Lim, H. S., Zellerhoff, S., Derval, N., Denis, A., Yamashita, S., Berte, B., Mahida, S., Hooks, D. A., Al-Jefairi, N., Shah, A. J., et al. (2014) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2014.11.004 · Cited by 29 · see citing works
Flexible MEA for adult zebrafish ECG recording covering both ventricle and atrium
Zhang, X., Tai, J., Park, J., et al. (2014) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.2014.6765772 · Cited by 11 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- [6]Zhang X Tai J Park J Tai Y-C 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS) 841 844 IEEE
- [55]Fang Hui Dataset for [Capacitively Coupled Arrays of Multiplexed Flexible Silicon Transistors for Long-Term Cardiac Electrophysiology] figshare https://figshare.com/s/961786fcede5a8703ec5 2017 PMC5552067 28804678
Cited by
Sorted by citations
Flexible Electronics: Stretchable Electrodes and Their Future
Huang, S., Liu, Y., Zhao, Y., Ren, Z., & Guo, C. F. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201805924 · Cited by 855 · see citing works
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609 · see citing works
Enabling Technologies for Personalized and Precision Medicine
Ho, D., Quake, S. R., McCabe, E. R. B., Chng, W. J., Chow, E. K., Ding, X., Gelb, B. D., Ginsburg, G. S., Hassenstab, J., Ho, C.-M., et al. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.12.021 · Cited by 517 · see citing works
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498 · see citing works
Self-citationNyein, H. Y. Y., Bariya, M., Kivimäki, L., Uusitalo, S., Liaw, T. S., Jansson, E., Ahn, C. H., Hangasky, J. A., Zhao, J., Lin, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw9906 · Cited by 388 · see citing works
Self-citationKim, H.-J., Sim, K., Thukral, A., & Yu, C. (2017) · Science Advances · doi:10.1126/sciadv.1701114 · Cited by 274 · see citing works
A flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278 · see citing works
Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay4682 · Cited by 211 · see citing works
Self-citationLi, Q., Nan, K., Le Floch, P., Lin, Z., Sheng, H., Blum, T. S., & Liu, J. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02512 · Cited by 224 · see citing works
Herbert, R., Kim, J.-H., Kim, Y., Lee, H., & Yeo, W.-H. (2018) · Materials · doi:10.3390/ma11020187 · Cited by 220 · see citing works
Recent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206 · see citing works
Self-citationShi, Q., & Lee, C. (2019) · Advanced Science · doi:10.1002/advs.201900617 · Cited by 174 · see citing works
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113 · see citing works
Conductively coupled flexible silicon electronic systems for chronic neural electrophysiology
Li, J., Song, E., Chiang, C.-H., Yu, K. J., Koo, J., Du, H., Zhong, Y., Hill, M., Wang, C., Zhang, J., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813187115 · Cited by 65 · see citing works
Self-citationRecent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25 · see citing works
Design and applications of conductive polymers in wearable electrophysiological sensing
Zhou, N., Zhang, L., Cui, T., Wu, P., & Lei, Z. (2025) · Science China Technological Sciences · doi:10.1007/s11431-025-3114-6 · Cited by 9 · see citing works
- Authors
- Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., Zhong, Y., Han, S. W., Xue, Y., Xu, D., Choi, S. W., Cauwenberghs, G., Kay, M., Huang, Y., Viventi, J., Efimov, I. R., & Rogers, J. A.
- Affiliations
- Northeastern University (US)
- University of Illinois Urbana-Champaign (US)
- George Washington University (US)
- Duke University (US)
- Northwestern University (US)
- University of California San Diego (US)
- Corresponding author
- Efimov, Igor R.
- Rogers, John A.
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2017-03-01
- Volume
- 1
- Issue
- 3
- ISSN
- 2157-846X (ISSN-L)
- PMC
- PMC5552067
- OpenAlex
- W2593247569
- Cited by
- 278
- References
- 53
- Citations by year
- 2026: 8 · 2025: 30 · 2024: 17 · 2023: 27 · 2022: 35 · 2021: 35 · 2020: 42 · 2019: 34 · 2018: 41 · 2017: 9
- FWCI
- 16.87
- Type
- journal article
- Language
- en
- Update notices
- erratum (2017-03-09)
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- National Institutes of Health
- National Heart, Lung, and Blood Institute (R01HL115415, R21HL112278, R01HL114395)
- National Institute of Neurological Disorders and Stroke (U01NS099697)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- flexible electronics, capacitive coupling, silicon transistors, cardiac electrophysiology, implantable electronics, cardiac arrhythmias, Langendorff heart, multiplexed sensor arrays
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review