27.3 All-wireless 64-channel 0.013mm2/ch closed-loop neurostimulator with rail-to-rail DC offset removal
The DOI matches its Crossref record.
Abstract
Accurate capture and efficient control of neurological disorders such as epileptic seizures that often originate in multiple regions of the brain, requires neural interface microsystems with an ever-increasing need for higher channel counts. Addressing this demand within the limited energy and area of brain-implantable medical devices necessitates a search for new circuit architectures. In the conventional designs [1-5], the channel area is dominated by the bulky coupling capacitors and/or capacitor banks of the in-channel ADC, both unavoidable due to the channel architecture, and unscalable with CMOS technology. Additionally, channel power consumption, typically dominated by the LNA, cannot be reduced lower than a certain limit without sacrificing gain and/or noise performance. In this paper, we present a 64-channel wireless closed-loop neurostimulator with a compact and energy-efficient channel architecture that performs both amplification and digitization in a single ΔΣ-based neural ADC, while removing rail-to-rail input DC offset using a digital feedback loop. The channel area and power consumption depend only on the active components and switching frequency, respectively, making the design both technology- and frequency-scalable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125
Track-and-Zoom Neural Analog-to-Digital Converter With Blind Stimulation Artifact Rejection
Reza Pazhouhandeh, M., Chang, M., Valiante, T. A., & Genov, R. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991526 · Cited by 74
“3(c) shows a dc-coupled 2 -modulated neural-ADC previously reported in [16] and [17].”
Self-citationDabbaghian, A., Yousefi, T., Fatmi, S. Z., Shafia, P., & Kassiri, H. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2936327 · Cited by 56
Self-citation
Metadata
- Authors
- Kassiri, H., Pazhouhandeh, R., Soltani, N., Salam, M. T., Carlen, P., Velazquez, J. L. P., & Genov, R.
- Venue
- 2017 IEEE International Solid-State Circuits Conference (ISSCC)
- Publisher
- IEEE
- Published
- 2017-02
- Pages
- 452-453
- ISSN
- 0193-6530 (ISSN-L)
- OpenAlex
- W2591728046
- Cited by
- 51
- References
- 0
- FWCI
- 16.12
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 27.3 All-wireless 64-channel 0.013mm2/ch closed-loop neurostimulator with rail-to-rail DC offset removal. https://app.cochat.ai/papers/10.1109/isscc.2017.7870456
- The paper
- Kassiri, H., Pazhouhandeh, R., Soltani, N., Salam, M. T., Carlen, P., Velazquez, J. L. P., & Genov, R. (2017). 27.3 All-wireless 64-channel 0.013mm2/ch closed-loop neurostimulator with rail-to-rail DC offset removal. 2017 IEEE International Solid-State Circuits Conference (ISSCC). https://doi.org/10.1109/isscc.2017.7870456
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.