17.5 A 0.8mm3 Ultrasonic Implantable Wireless Neural Recording System With Linear AM Backscattering
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Miniaturization of implantable neural recording systems to micron-scale volumes will enable minimally invasive implantation and alleviate cortical scarring, gliosis, and resulting signal degradation. Ultrasound (US) power transmission has been demonstrated to have high efficiency and low tissue attenuation for mm-scale implants at depth in tissue [1, 2, 3], but has not been demonstrated with precision recording circuitry. We present an US implantable wireless neural recording system scaled to 0.8mm3, verified to safely operate at 5cm depth with state of the art neural recording performance an average circuit power dissipation of 13μW, and 28.8μW including power conversion efficiency. Sub-mm scale is achieved through single-link power and communication on a single piezocrystal (Lead Zirconate Titanate, PZT) utilizing linear analog backscattering, small die area, and eliminating all other off-chip components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557 · cited 2×
“5×, and a static nonlinearity 40× lower than state of the art [1,4,5].”
BackgroundSelf-citation
Cited by
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Zaeimbashi, M., Nasrollahpour, M., Khalifa, A., Romano, A., Liang, X., Chen, H., Sun, N., Matyushov, A., Lin, H., Dong, C., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23256-z · Cited by 201
ElAnsary, M., Xu, J., Filho, J. S., Dutta, G., Long, L., Tejeiro, C., Shoukry, A., Tang, C., Kilinc, E., Joshi, J., et al. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3113354 · Cited by 48
Metadata
- Authors
- Ghanbari, M. M., Piech, D. K., Shen, K., Alamouti, S. F., Yalcin, C., Johnson, B. C., Carmena, J. M., Maharbiz, M. M., & Muller, R.
- Venue
- 2019 IEEE International Solid- State Circuits Conference - (ISSCC)
- Publisher
- IEEE
- Published
- 2019-02
- Pages
- 284-286
- ISSN
- 0193-6530 (ISSN-L)
- OpenAlex
- W2922423338
- Cited by
- 42
- References
- 1
- FWCI
- 24.30
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.