Bidirectional Peripheral Nerve Interface With 64 Second-Order Opamp-Less ΔΣ ADCs and Fully Integrated Wireless Power/Data Transmission
Abstract
An active probe and microstimulator SoC for interfacing with peripheral nerves is presented. It performs 64-channel artifact-tolerant neural recording, cuff imbalance compensation by impedance sensing, and neurostimulation for the closed-loop operation. Each recording channel is a second-order opamp-less$\Delta \Sigma $ADC that consumes 140 nW and occupies 0.01 mm2area in 130 nm CMOS. The single-loop$\Delta \Sigma $architecture achieves second-order noise shaping with two passive integrators. To the best of our knowledge, this yields the lowest power and area of any second-order$\Delta \Sigma $ADC and the lowest FOM (fJ/conv. step) of any passive second-order$\Delta \Sigma $ADC (27 fJ/conv. step). The SoC uniquely performs multi-modal input signal recording: voltage (for neural recording) and current (for impedance sensing) are measured concurrently using frequency multiplexing. The SoC also features a 60 MHz energy-efficient inductive powering link and a 600 MHz RF data communication link. The prototype is validatedin vivoin the rat sciatic nerve for electroneurogram (ENG) sensing and the correction of impedance-imbalance in cuff electrodes.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Recording circuits developed for the PNS have strict requirements of noise cancellation due to the proximity of sources of biosignal interference including electromyogram and electrocardiogram which are orders of magnitude larger than the signals of interest.
“Recording circuits developed for the PNS have strict requirements of noise cancellation due to the proximity of sources of biosignal interference including electromyogram and electrocardiogram which are orders of magnitude larger than the signals of interest [54].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [54]
Cites
Understanding Delta‐Sigma Data Converters
Schreier, R., Pavan, S., & Temes, G. C. (2017) · Wiley eBooks · doi:10.1002/9781119258308 · Cited by 1,972 · see citing works
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R. R., Watkins, P., Kier, R. J., Lovejoy, R. O., Black, D., Normann, R. A., & Solzbacher, F. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696288 · Cited by 731 · see citing works
A jump-start for electroceuticals
Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. (2013) · Nature · doi:10.1038/496159a · Cited by 554 · see citing works
Fiber composition of the rat sciatic nerve
Schmalbruch, H. (1986) · The Anatomical Record · doi:10.1002/ar.1092150111 · Cited by 402 · see citing works
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230 · see citing works
Sensory nerve recording for closed‐loop control to restore motor functions
Popovic, D. B., Stein, R. B., Jovanovic, K. L., Dai, R., Kostov, A., & Armstrong, W. W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247801 · Cited by 159 · see citing works
Chronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144 · see citing works
Robust Wireless Power Transmission to mm-Sized Free-Floating Distributed Implants
Mirbozorgi, S. A., Yeon, P., & Ghovanloo, M. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2663358 · Cited by 128 · see citing works
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115 · see citing works
Haugland, M. K., Lickel, A., Haase, J., & Sinkjær, T. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.769412 · Cited by 112 · see citing works
Rhew, H.-G., Jeong, J., Fredenburg, J. A., Dodani, S., Patil, P. G., & Flynn, M. P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2346779 · Cited by 104 · see citing works
Lin, Y.-P., Yeh, C.-Y., Huang, P.-Y., Wang, Z.-Y., Cheng, H.-H., Li, Y., Chuang, C.-F., Huang, P.-C., Tang, K., Ma, H., et al. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2403282 · Cited by 100 · see citing works
Instrumentation for ENG and EMG recordings in FES systems
Nikolić, Z., Popović, D. B., Stein, R. B., & Kenwell, Z. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.301739 · Cited by 91 · see citing works
A 0.25-mW low-pass passive sigma-delta modulator with built-in mixer for a 10-MHz IF input
Chen, F., & Leung, B. (1997) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.585244 · Cited by 83 · see citing works
A Fully Integrated Wireless SoC for Motor Function Recovery After Spinal Cord Injury
Lo, Y., Kuan, Y., Culaclii, S., Kim, B., Wang, P., Chang, C.-W., Massachi, J., Zhu, M., Chen, K., Gad, P. N., et al. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2679441 · Cited by 78 · see citing works
Tripolar nerve cuff recording: stimulus artifact, EMG and the recorded nerve signal
Struijk, J. J., & Thomsen, M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1995.579534 · Cited by 76 · see citing works
Natural neural sensing and artificial muscle control in man
Sinkjær, T., Haugland, M. K., & Haase, J. (1994) · Experimental Brain Research · doi:10.1007/bf00233991 · Cited by 69 · see citing works
Nanostructured CMOS Wireless Ultra-Wideband Label-Free PCR-Free DNA Analysis SoC
Jafari, H. M., Abdelhalim, K., Soleymani, L., Sargent, E. H., Kelley, S. O., & Genov, R. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2312571 · Cited by 62 · see citing works
Self-citationBozorgzadeh, B., Schuweiler, D. R., Bobak, M. J., Garris, P. A., & Mohseni, P. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2453791 · Cited by 61 · see citing works
Low-Power DT $\Delta \Sigma$ Modulators Using SC Passive Filters in 65 nm CMOS
Yeknami, A. F., Qazi, F., & Alvandpour, A. (2013) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2013.2278346 · Cited by 54 · see citing works
Real Time Foot Drop Correction using Machine Learning and Natural Sensors
Hansen, M., Haugland, M. K., Sinkjær, T., & Donaldson, N. (2002) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2002._2008.x · Cited by 52 · see citing works
Rahal, M., Winter, J., Taylor, J. T., & Donaldson, N. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867963 · Cited by 47 · see citing works
Jung, J., Zhu, S., Liu, P., et al. (2010) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2010.2088137 · Cited by 47 · see citing works
A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
Ng, K. A., Yuan, C., Rusly, A., Do, A. T., Zhao, B., Liu, S.-C., Peh, W. Y. X., Thow, X. Y., Voges, K., Lee, S., et al. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2909158 · Cited by 47 · see citing works
On Cuff Imbalance and Tripolar ENG Amplifier Configurations
Triantis, I. F., Demosthenous, A., & Donaldson, N. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840470 · Cited by 45 · see citing works
17.5 A 0.8mm3 Ultrasonic Implantable Wireless Neural Recording System With Linear AM Backscattering
Ghanbari, M. M., Piech, D. K., Shen, K., et al. (2019) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2019.8662295 · Cited by 43 · see citing works
50nW Opamp-Less ΔΣ-Modulated Bioimpedance Spectrum Analyzer for Electrochemical Brain Interfacing
ElAnsary, M., Soltani, N., Kassiri, H., et al. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2981033 · Cited by 37 · see citing works
Self-citationLow Power OOK Transmitter for Wireless Capsule Endoscope
Ryu, J., Kim, M., Lee, J., et al. (2007) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2007.380113 · Cited by 36 · see citing works
Artefact reduction with alternative cuff configurations
Struijk, L. N. S. A., & Struijk, J. J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.817633 · Cited by 33 · see citing works
Pazhouhandeh, M. R., OrLeary, G., Weisspapir, I., et al. (2019) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2019.8662458 · Cited by 31 · see citing works
A 0.7 V 256 μW ΔΣ modulator with passive RC integrators achieving 76 dB DR in 2 MHz BW
de Melo, J. L. A., Goês, J., & Paulino, N. (2015) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2015.7231294 · Cited by 25 · see citing works
An Adaptive Averaging Low Noise Front-End for Central and Peripheral Nerve Recording
Lee, B., & Ghovanloo, M. (2017) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2017.2725988 · Cited by 24 · see citing works
Active–Passive $\Delta \Sigma $ Modulator for High-Resolution and Low-Power Applications
Hussain, A., Sin, S., Chan, C., et al. (2016) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2016.2580712 · Cited by 22 · see citing works
A 0.4-V 410-nW opamp-less continuous-time ΣΔ modulator for biomedical applications
de Melo, J. L. A., Querido, F., Paulino, N., et al. (2014) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2014.6865391 · Cited by 20 · see citing works
A Third-Order MASH $\Sigma \Delta $ Modulator Using Passive Integrators
Nowacki, B., Paulino, N., & Goês, J. (2017) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2017.2704164 · Cited by 19 · see citing works
Wireless powering of mm-scale fully-on-chip neural interfaces
Park, J., Kim, C., Akinin, A., et al. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325186 · Cited by 19 · see citing works
Intraneural active probe for bidirectional peripheral nerve interface
Ballini, M., Bae, J., Marrocco, N., Verplancke, R., Schaubroeck, D., Cuypers, D., Cauwe, M., O'Callaghan, J., Fahmy, A., Maghari, N., et al. (2017) · 2017 Symposium on VLSI Circuits · doi:10.23919/vlsic.2017.8008544 · Cited by 16 · see citing works
A 900-MHz low-power transmitter with fast frequency calibration for wireless sensor networks
Panitantum, N., Mayaram, K., & Fiez, T. S. (2008) · IEEE Custom Integrated Circuits Conference (CICC) · doi:10.1109/cicc.2008.4672156 · Cited by 15 · see citing works
An ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces
Lancashire, H. T., Jiang, D., Demosthenous, A., & Donaldson, N. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891284 · Cited by 15 · see citing works
Ultra low power pulse generator based on a ring oscillator with direct path current avoidance
Veirano, F., Pérez, P., Besio, S., et al. (2013) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas.2013.6519036 · Cited by 14 · see citing works
Struijk, L. N. S. A., & Struijk, J. J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.819848 · Cited by 14 · see citing works
Remote Powering and Data Communication for Implanted Biomedical Systems
Kilinc, E. G., Dehollain, C., & Maloberti, F. (2015) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-319-21179-4 · Cited by 13 · see citing works
Self-citationLow power and low phase noise 5.7 GHz LC VCO in OOK transmitter for neurosensory application
Upadhyaya, P., Rajashekharaiah, M., Heo, D., et al. (2005) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2005.1516989 · Cited by 7 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11 · see citing works
“Recording circuits developed for the PNS have strict requirements of noise cancellation due to the proximity of sources of biosignal interference including electromyogram and electrocardiogram which are orders of magnitude larger than the signals of interest [54].”
- Authors
- ElAnsary, M., Xu, J., Filho, J. S., Dutta, G., Long, L., Tejeiro, C., Shoukry, A., Tang, C., Kilinc, E., Joshi, J., Sabetian, P., Unger, S., Zariffa, J., Yoo, P., & Genov, R.
- Affiliations
- Ain Shams University (EG)
- University of Toronto (CA)
- ORCID
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2021-11
- Volume
- 56
- Issue
- 11
- Pages
- 3247-3262
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W3204012403
- Cited by
- 48
- References
- 43
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 8 · 2023: 16 · 2022: 8
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council (NSERC) of Canada
- Canada Foundation for Innovation
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- peripheral nerve interfaces, neural recording, neurostimulation, low-power analog-to-digital converter, inductive power transfer, RF data transmission, electroneurogram, rat sciatic nerve, frequency multiplexing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review