Unsupervised Classifier Self-Calibration through Repeated Context Occurences: Is there Robustness against Sensor Displacement to Gain?
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Achieving a robust recognition of physical activities or gestures despite variability in sensor placement is highly important for the real-world deployment of wearable context-aware systems.It provides robustness against unintentional displacement of sensors, such as when doing intense physical activities or wearing sensors over extended periods of time.Here we focus on the problem of context recognition when sensors are displaced on body segments. We present an online unsupervised classifier self-calibration algorithm.Upon re-occurring context occurrences, the self-calibration algorithm adjusts the decision boundaries through online learning to better reflect the classes statistics, effectively allowing to track and adjust when classes drift in the feature space.We characterize the theoretical behavior of the system on a synthetic two-class problem dataset.We then analyze the real-world applicability of the method on a 5-class HCI related dataset, and a 6-class fitness scenario dataset.Our results show that the calibration increases the classification accuracy for displaced sensor positions by 33.3% in the HCI scenario and by 13.4% in the fitness scenario.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Activity Recognition from On-Body Sensors: Accuracy-Power Trade-Off by Dynamic Sensor Selection
Zappi, P., Lombriser, C., Stiefmeier, T., Farella, E., Roggen, D., Benini, L., & Tröster, G. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-77690-1_2 · Cited by 329
Self-citationDealing with sensor displacement in motion-based onbody activity recognition systems
Kunze, K., & Lukowicz, P. (2008) · Proceedings of the 10th international conference on Ubiquitous computing · doi:10.1145/1409635.1409639 · Cited by 161
Cited by
Convolutional Neural Networks for Human Activity Recognition using Mobile Sensors
Zeng, M., Nguyen, L. T., Yu, B., Mengshoel, O. J., Zhu, J., Wu, P., & Zhang, J. (2014) · Proceedings of the 6th International Conference on Mobile Computing, Applications and Services · doi:10.4108/icst.mobicase.2014.257786 · Cited by 876
“Applications that can benefit from AR include daily lifelogging, healthcare, senior care, personal fitness, etc. [7], [32], [31], [9].”
BackgroundCollecting complex activity datasets in highly rich networked sensor environments
Roggen, D., Calatroni, A., Rossi, M., Holleczek, T., Forster, K., Troster, G., Lukowicz, P., Bannach, D., Pirkl, G., Ferscha, A., et al. (2010) · 2010 Seventh International Conference on Networked Sensing Systems (INSS) · doi:10.1109/inss.2010.5573462 · Cited by 788
Self-citationA benchmark dataset to evaluate sensor displacement in activity recognition
Baños, O., Damas, M., Pomares, H., Rojas, I., Tóth, M. A., & Amft, O. (2012) · Proceedings of the 2012 ACM Conference on Ubiquitous Computing · doi:10.1145/2370216.2370437 · Cited by 163
Dealing with the Effects of Sensor Displacement in Wearable Activity Recognition
Banos, O., Toth, M., Damas, M., Pomares, H., & Rojas, I. (2014) · Sensors · doi:10.3390/s140609995 · Cited by 159
Sensor Placement Variations in Wearable Activity Recognition
Kunze, K., & Lukowicz, P. (2014) · IEEE Pervasive Computing · doi:10.1109/mprv.2014.73 · Cited by 111
Metadata
- Authors
- Forster, K., Roggen, D., & Troster, G.
- Venue
- 2009 International Symposium on Wearable Computers
- Publisher
- IEEE
- Published
- 2009-09
- Pages
- 77-84
- OpenAlex
- W2158690549
- Cited by
- 73
- References
- 2
- FWCI
- 5.45
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unsupervised Classifier Self-Calibration through Repeated Context Occurences: Is there Robustness against Sensor Displacement to Gain? https://app.cochat.ai/papers/10.1109/iswc.2009.12
- The paper
- Forster, K., Roggen, D., & Troster, G. (2009). Unsupervised Classifier Self-Calibration through Repeated Context Occurences: Is there Robustness against Sensor Displacement to Gain? 2009 International Symposium on Wearable Computers. https://doi.org/10.1109/iswc.2009.12
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.