A New Wristband Wearable Sensor Using Adaptive Reduction Filter to Reduce Motion Artifact
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Reduction the motion artifact from photo plethysmograph (PPG) signals can improve the precision of the measurement of heart rate or arterial oxygen saturation in movement state. This paper presents a new wristband PPG/ACC sensor device, which utilizes the adaptive filter technique to reduce the motion artifact of the original PPG signals. A 3-axis MEMS accelerometer sensor is attached to the PPG sensor to detect the wrist movement. A fast transversal RLS algorithm is performed to reduce the computed complexity of the adaptive filter. Experiment results show that this device can provide more reliable and stable signals against motion artifact corruption under the typical types of movement, such as swinging arms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235 · cited 3×
“The most important parameter that should be considered carefully and chosen properly was the FIR model order N. Pervious research have indicated that the dynamic impulse response between motion to artifact had a 90~120ms duration [12].”
BackgroundMethodInfluential
Cited by
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“In another study, a triaxial MEMS accelerometer was attached to a PPG sensor to detect wrist movement [56].”
BackgroundMethodCurrent progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
“1 3 complexity of the adaptive filter by providing an estimate of the linear motion-to-artefact transfer function [78].”
BackgroundMethodAn optimal filter for short photoplethysmogram signals
Liang, Y., Elgendi, M., Chen, Z., & Ward, R. (2018) · Scientific Data · doi:10.1038/sdata.2018.76 · Cited by 242
Heart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101
“[25] designed a wrist band type PPG sensor in which triaxis Micro Electro-Mechanical Systems (MEMS) ACC sensors were used and put forth the idea that two ACC axis can be used for the reduction of MAs using fast transversal recursive least squares filter (FTRLSF) algorithm.”
BackgroundMethod
Metadata
- Authors
- Wei, P., Guo, R., Zhang, J., & Zhang, Y. T.
- Venue
- 2008 International Conference on Information Technology and Applications in Biomedicine
- Publisher
- IEEE
- Published
- 2008-05
- Pages
- 278-281
- OpenAlex
- W2157716872
- Cited by
- 42
- References
- 2
- FWCI
- 5.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.