Enhanced thermal management by direct water spray of high-voltage, high power devices in a three-phase, 18-hp AC motor drive demonstration
The DOI matches its Crossref record.
Abstract
The combination of high power dissipation (e.g., >500 W) and high power densities required of power conversion devices, such as those utilized within variable-speed motor drives, necessitates thermal management systems with ever-increasing capabilities. Although device power densities on the order of 100 W/cm/sup 2/ are relatively common in applications today, technology roadmaps project power densities in excess of 1 kW/cm/sup 2/ within a few years. Unfortunately, conventional thermal management designs based on solid-state conduction become unworkable at such power densities. In the present DARPA-funded investigation we have approached this problem through implementation of direct low-pressure water spray-cooling of both switch and diode surfaces within a variable-speed motor drive. Problems that were addressed include the packaging of a nozzle array design in a high-power module (>650 W dissipation) that operates with high standoff voltages (V/sub rms//spl sim/325 VAC). Electrical isolation of the devices was achieved by a Parylene coating. An effective thermal resistance of /spl sim/0.007 C/W was achieved through direct water spray-cooling of the electronic devices. In the presentation, we will compare the calculated and measured spray-cooling thermal resistances to those of more conventional thermal management schemes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thermal Management on IGBT Power Electronic Devices and Modules
Qian, C., Gheitaghy, A. M., Fan, J., Tang, H., Sun, B., Ye, H., & Zhang, G. (2018) · IEEE Access · doi:10.1109/access.2018.2793300 · Cited by 342
Advances in Power Conversion and Drives for Shipboard Systems
Wang, F., Zhang, Z., Ericsen, T., Raju, R., Burgos, R., & Boroyevich, D. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2495331 · Cited by 135
Liquid Jet Impingement Cooling of a Silicon Carbide Power Conversion Module for Vehicle Applications
Gould, K., Cai, S. Q., Neft, C., & Bhunia, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2331562 · Cited by 93
Transient Thermal Performance of IGBT Power Modules Attached by Low-Temperature Sintered Nanosilver
Chen, G., Han, D., Mei, Y.-H., Cao, X., Wang, T., Chen, X., & Lu, G.-Q. (2012) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2011.2173573 · Cited by 71
Metadata
- Authors
- Shaw, M. C., Waldrop, J. R., Chandrasekaran, S., Kagalwala, B., Jing, X., Brown, E. R., Dhir, V. J., & Fabbeo, M.
- Venue
- ITherm 2002. Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (Cat. No.02CH37258)
- Publisher
- IEEE
- Published
- 2003-06-25
- Pages
- 1007-1014
- ISSN
- 1087-9870 (ISSN-L)
- OpenAlex
- W2143280393
- Cited by
- 39
- References
- 0
- FWCI
- 10.09
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced thermal management by direct water spray of high-voltage, high power devices in a three-phase, 18-hp AC motor drive demonstration. https://app.cochat.ai/papers/10.1109/itherm.2002.1012567
- The paper
- Shaw, M. C., Waldrop, J. R., Chandrasekaran, S., Kagalwala, B., Jing, X., Brown, E. R., Dhir, V. J., & Fabbeo, M. (2003). Enhanced thermal management by direct water spray of high-voltage, high power devices in a three-phase, 18-hp AC motor drive demonstration. ITherm 2002. Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (Cat. No.02CH37258). https://doi.org/10.1109/itherm.2002.1012567
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.