Computer-Aided Bleeding Detection in WCE Video
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Wireless capsule endoscopy (WCE) can directly take digital images in the gastrointestinal tract of a patient. It has opened a new chapter in small intestine examination. However, a major problem associated with this technology is that too many images need to be manually examined by clinicians. Currently, there is no standard for capsule endoscopy image interpretation and classification. Most state-of-the-art CAD methods often suffer from poor performance, high computational cost, or multiple empirical thresholds. In this paper, a new method for rapid bleeding detection in the WCE video is proposed. We group pixels through superpixel segmentation to reduce the computational complexity while maintaining high diagnostic accuracy. Feature of each superpixel is extracted using the red ratio in RGB space and fed into support vector machine for classification. Also, the influence of edge pixels has been removed in this paper. Comparative experiments show that our algorithm is superior to the existing methods in terms of sensitivity, specificity, and accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
SLIC Superpixels Compared to State-of-the-Art Superpixel Methods
Achanta, R., Shaji, A., Smith, K., Lucchi, A., Fua, P., & Süsstrunk, S. (2012) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.120 · Cited by 9,201
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Digital Image Processing: PIKS Scientific Inside
Pratt, W. K. (2007) · Wiley eBooks · doi:10.1002/0470097434 · Cited by 2,616
Learning a classification model for segmentation
Ren, & Malik (2003) · Proceedings Ninth IEEE International Conference on Computer Vision · doi:10.1109/iccv.2003.1238308 · Cited by 1,765
TurboPixels: Fast Superpixels Using Geometric Flows
Levinshtein, A., Stere, A., Kutulakos, K. N., Fleet, D. J., Dickinson, S. J., & Siddiqi, K. (2009) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2009.96 · Cited by 1,146
Zuckerman, G. R., Gyawali, C. P., Askin, M. P., & Lewis, B. S. (2000) · Gastroenterology · doi:10.1016/s0016-5085(00)70430-6 · Cited by 501
Computer-Aided Detection of Bleeding Regions for Capsule Endoscopy Images
Li, B., & Meng, M. Q.-H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010526 · Cited by 223
Self-citationMPEG-7 Visual Descriptors—Contributions for Automated Feature Extraction in Capsule Endoscopy
Coimbra, M. T., & Cunha, J. P. S. (2006) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2006.873158 · Cited by 185
Li, B., & Meng, M. Q.-H. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2185807 · Cited by 182
Self-citationTexture analysis for ulcer detection in capsule endoscopy images
Li, B., & Meng, M. Q.-H. (2009) · Image and Vision Computing · doi:10.1016/j.imavis.2008.12.003 · Cited by 170
Self-citationBleeding Detection in Wireless Capsule Endoscopy Based on Probabilistic Neural Network
Pan, G., Yan, G., Qiu, X., & Cui, J. (2010) · Journal of Medical Systems · doi:10.1007/s10916-009-9424-0 · Cited by 137
Performance of Given Suspected Blood Indicator
Liangpunsakul, S., Mays, L., & Rex, D. K. (2003) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2003.08731.x · Cited by 94
Wireless Capsule Endoscopy and Endoscopic Imaging: A Survey on Various Methodologies Presented
Karargyris, A., & Bourbakis, N. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2009.935466 · Cited by 85
Computer-aided small bowel tumor detection for capsule endoscopy
Li, B., Meng, M. Q. ‐., & Lau, J. (2011) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2011.01.003 · Cited by 73
Self-citationWireless capsule endoscopy images enhancement via adaptive contrast diffusion
Li, B., & Meng, M. Q. ‐. (2011) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2011.10.002 · Cited by 52
Self-citationObscure bleeding detection in endoscopy images using support vector machines
Liu, J., & Yuan, X. (2008) · Optimization and Engineering · doi:10.1007/s11081-008-9066-y · Cited by 47
A Technique For Blood Detection In Wireless Capsule Endoscopy Images
Grangetto, M., Magli, E., Olmo, G., Penna, B., & Tillo, T. (2009) · doi:10.5281/zenodo.41479 · Cited by 38
Bleeding region detection in WCE images based on color features and neural network
Fu, Y., Mandal, M. K., & Guo, G. (2011) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2011.6026527 · Cited by 36
Self-citationFeature selection and classification for Wireless Capsule Endoscopic frames
Poh, C. K., Zhang, Z., Yang, L. Z., Li, L., & Liu, J. (2009) · International Conference on Biomedical and Pharmaceutical Engineering · doi:10.1109/icbpe.2009.5384106 · Cited by 32
Cited by
Application of Artificial Intelligence to Gastroenterology and Hepatology
Le Berre, C., Sandborn, W. J., Aridhi, S., Devignes, M.-D., Fournier, L., Smaïl-Tabbone, M., Danese, S., & Peyrin-Biroulet, L. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.08.058 · Cited by 516
Deep learning for wireless capsule endoscopy: a systematic review and meta-analysis
Soffer, S., Klang, E., Shimon, O., Nachmias, N., Eliakim, R., Ben-Horin, S., Kopylov, U., & Barash, Y. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.04.039 · Cited by 207
A deep convolutional neural network for bleeding detection in Wireless Capsule Endoscopy images
Jia, X., & Meng, M. Q.-H. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590783 · Cited by 201
“(a)-(c): The comparison of recall, precision and F1 score amongst [3], [21] and our method.”
MethodResultInfluentialSelf-citationBleeding Frame and Region Detection in the Wireless Capsule Endoscopy Video
Yuan, Y., Li, B., & Meng, M. Q.-H. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2399502 · Cited by 167
Self-citationArtificial intelligence in gastroenterology: A state-of-the-art review
Kröner, P. T., Engels, M. M., Glicksberg, B. S., Johnson, K. W., Mzaik, O., van Hooft, J. E., Wallace, M. B., El-Serag, H. B., & Krittanawong, C. (2021) · World Journal of Gastroenterology · doi:10.3748/wjg.v27.i40.6794 · Cited by 165
Metadata
- Authors
- Fu, Y., Zhang, W., Mandal, M., & Meng, M. Q.-H.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2014-03
- Volume
- 18
- Issue
- 2
- Pages
- 636-642
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1995517024
- Cited by
- 183
- References
- 21
- FWCI
- 9.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.