Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Deep learning for wireless capsule endoscopy: a systematic review and meta-analysis

Soffer, Shelly, Klang, Eyal, Shimon, Orit, Nachmias, Noy, Eliakim, Rami, Ben-Horin, Shomron, Kopylov, Uri, Barash, Yiftach·2020·Gastrointestinal Endoscopy

Abstract

BACKGROUND AND AIMS Deep learning is an innovative algorithm based on neural networks. Wireless capsule endoscopy (WCE) is considered the criterion standard for detecting small-bowel diseases. Manual examination of WCE is time consuming and can benefit from automatic detection using artificial intelligence (AI). We aimed to perform a systematic review of current literature pertaining to deep learning implementation in WCE. METHODS We conducted a search in PubMed for all original publications on the subject of deep learning applications in WCE published between January 1, 2016, and December 15, 2019. Evaluation of the risk of bias was performed using tailored Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Pooled sensitivity and specificity were calculated. Summary receiver operating characteristic curves were plotted. RESULTS Of the 45 studies retrieved, 19 studies were included. All studies were retrospective. Deep learning applications for WCE included detection of ulcers, polyps, celiac disease, bleeding, and hookworm. Detection accuracy was above 90% for most studies and diseases. The pooled sensitivity and specificity for ulcer detection were 0.95 (95% CI, 0.89-0.98) and 0.94 (95% CI, 0.90-0.96), respectively. The pooled sensitivity and specificity for bleeding or bleeding source were 0.98 (95% CI, 0.96-0.99) and 0.99 (95% CI, 0.97-0.99), respectively. CONCLUSIONS Deep learning has achieved excellent performance for the detection of a range of diseases in WCE. Notwithstanding, current research is based on retrospective studies with a high risk of bias. Thus, future prospective multicenter studies are necessary in order for this technology to be implemented in the clinical use of WCE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gie.2020.04.039

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 207

Metadata

Authors
Soffer, S., Klang, E., Shimon, O., Nachmias, N., Eliakim, R., Ben-Horin, S., Kopylov, U., & Barash, Y.
Venue
Gastrointestinal Endoscopy
Publisher
Elsevier BV
Published
2020-10
Volume
92
Issue
4
Pages
831-839.e8
ISSN
0016-5107 (ISSN-L)
OpenAlex
W3019872864
Cited by
207
References
13
FWCI
6.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep learning for wireless capsule endoscopy: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.gie.2020.04.039
The paper
Soffer, S., Klang, E., Shimon, O., Nachmias, N., Eliakim, R., Ben-Horin, S., Kopylov, U., & Barash, Y. (2020). Deep learning for wireless capsule endoscopy: a systematic review and meta-analysis. Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2020.04.039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.